Tomas Novotny

Dr. Tomas Novotny

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Journal of Electrocardiology
Verified
Journal Article
Open access
RBRaymond R. Bond
Raymond R. Bond
TNTomas Novotny
Tomas Novotny
IAIrena Andrsova
Irena Andrsova
LKLumir Koc
Lumir Koc
MSMartina Sisakova
Martina Sisakova
MMMarek Malik
Marek Malik
Interpretation of the 12‑lead Electrocardiogram (ECG) is normally assisted with an automated diagnosis (AD), which can facilitate an 'automation bias' where interpreters can be anchored. In this paper, we studied, 1) the effect of an incorrect AD on interpretation accuracy and interpreter confidence (a proxy for uncertainty), and 2) whether confidence and other interpreter features can predict interpretation accuracy using machine learning. This study analysed 9000 ECG interpretations from cardiology and non-cardiology fellows (CFs and non-CFs). One third of the ECGs involved no ADs, one third with ADs (half as incorrect) and one third had multiple ADs. Interpretations were scored and interpreter confidence was recorded for each interpretation and subsequently standardised using sigma scaling. Spearman coefficients were used for correlation analysis and C5.0 decision trees were used for predicting interpretation accuracy using basic interpreter features such as confidence, age, experience and designation. Interpretation accuracies achieved by CFs and non-CFs dropped by 43.20% and 58.95% respectively when an incorrect AD was presented (p < 0.001). Overall correlation between scaled confidence and interpretation accuracy was higher amongst CFs. However, correlation between confidence and interpretation accuracy decreased for both groups when an incorrect AD was presented. We found that an incorrect AD disturbs the reliability of interpreter confidence in predicting accuracy. An incorrect AD has a greater effect on the confidence of non-CFs (although this is not statistically significant it is close to the threshold, p = 0.065). The best C5.0 decision tree achieved an accuracy rate of 64.67% (p < 0.001), however this is only 6.56% greater than the no-information-rate. Incorrect ADs reduce the interpreter's diagnostic accuracy indicating an automation bias. Non-CFs tend to agree more with the ADs in comparison to CFs, hence less expert physicians are more effected by automation bias. Incorrect ADs reduce the interpreter's confidence and also reduces the predictive power of confidence for predicting accuracy (even more so for non-CFs). Whilst a statistically significant model was developed, it is difficult to predict interpretation accuracy using machine learning on basic features such as interpreter confidence, age, reader experience and designation.

21 February 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
KHKaterina Hnatkova
Katerina Hnatkova
IAIrena Andršová
Irena Andršová
TNTomas Novotny
Tomas Novotny
ABAnnie Britton
Annie Britton
MSMartin Shipley
Martin Shipley
MMMarek Malik
Marek Malik
Fragmented QRS complex with visible notching on standard 12-lead electrocardiogram (ECG) is understood to represent depolarization abnormalities and to signify risk of cardiac events. Depolarization abnormalities with similar prognostic implications likely exist beyond visual recognition but no technology is presently suitable for quantification of such invisible ECG abnormalities. We present such a technology. A signal processing method projects all ECG leads of the QRS complex into optimized three perpendicular dimensions, reconstructs the ECG back from this three-dimensional projection, and quantifies the difference (QRS ‘micro’-fragmentation, QRS-μf) between the original and reconstructed signals. QRS ‘micro’-fragmentation was assessed in three different populations: cardiac patients with automatic implantable cardioverter-defibrillators, cardiac patients with severe abnormalities, and general public. The predictive value of QRS-μf for mortality was investigated both univariably and in multivariable comparisons with other risk factors including visible QRS ‘macro’-fragmentation, QRS-Mf. The analysis was made in a total of 7779 subjects of whom 504 have not survived the first 5 years of follow-up. In all three populations, QRS-μf was strongly predictive of survival (P < 0.001 univariably, and P < 0.001 to P = 0.024 in multivariable regression analyses). A similar strong association with outcome was found when dichotomizing QRS-μf prospectively at 3.5%. When QRS-μf was used in multivariable analyses, QRS-Mf and QRS duration lost their predictive value. In three populations with different clinical characteristics, QRS-μf was a powerful mortality risk factor independent of several previously established risk indices. Electrophysiologic abnormalities that contribute to increased QRS-μf values are likely responsible for the predictive power of visible QRS-Mf. Principles of QRS micro-fragmentation.

1 November 2015 in Journal of Electrocardiology
Verified
Journal Article
Closed access
TNTomas Novotny
Tomas Novotny
RBRaymond Robert Bond
Raymond Robert Bond
IAIrena Andrsova
Irena Andrsova
LKLumir Koc
Lumir Koc
MSMartina Sisakova
Martina Sisakova
MMMarek Malik
Marek Malik

1 May 2017 in International Journal of Medical Informatics
Verified
Journal Article
Closed access
TNTomas Novotny
Tomas Novotny
RBRaymond Bond
Raymond Bond
IAIrena Andrsova
Irena Andrsova
LKLumir Koc
Lumir Koc
MSMartina Sisakova
Martina Sisakova
MMMarek Malik
Marek Malik

1 May 2007 in International Journal of Cardiology
Verified
Journal Article
Closed access
TNTomas Novotny
Tomas Novotny
AFAlena Florianova
Alena Florianova
ECEva Ceskova
Eva Ceskova
MWMarcela Weislamplova
Marcela Weislamplova
VPVitezslav Palensky
Vitezslav Palensky
JSJindrich Spinar
Jindrich Spinar

2 August 2017 in EP Europace
Verified
Journal Article
Open access
PDF file
JMJan Maňoušek
Jan Maňoušek
IAIrena Andršová
Irena Andršová
VSVera Stejskal
Vera Stejskal
JVJitka Vlašínová
Jitka Vlašínová
MSMilan Sepši
Milan Sepši
JŠJindřich Špinar
Jindřich Špinar
To evaluate whether patients with late complications of pacemakers or implantable cardioverter-defibrillators have hypersensitivity reactions to some of the materials used in generators or in electrodes, or to environmental metal burden. The cohort consisted of 20 men and 4 women (mean age: 62.3 ± 17.2 years) who had a history of late complications of implanted devices. The control group involved 25 men and 8 women (mean age: 64.6 ± 14.0 years) who had comparable devices, but no history of late complications. Lymphocyte transformation test was used to evaluate hypersensitivity to eight metal pollutants (antimony, manganese, mercury, molybdenum, nickel, platinum, tin, and titanium) selected by results of questionnaires on environmental burden, and by material analysis of generators and electrode surfaces. Exposures to metal pollutants were approximately the same in patients and in controls. Titanium alloy used in generators contained at least 99.32% of titanium and trace levels of other metals; higher levels of tin and platinum were detected in electrode surfaces. Hypersensitivity reactions to mercury and tin were significantly more frequent in patients than in controls (patients and controls: mercury: 68.2 and 31.1%, respectively; P = 0.022; tin: 25.0 and 3.2%, respectively; P = 0.035). In contrast, hypersensitivity to manganese was significantly more frequent in controls than in patients (patients and controls: 13.6 and 50.0%, respectively; P = 0.008). Our findings suggest a possible relation between hypersensitivity to metals used in implantable devices or to environmental metal burden and the occurrence of their late complications.