Hanhoon Park

Prof. Hanhoon Park

Division of Electronics and Communications Engineering, Pukyong National University, Busan 48513, Korea
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2019 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
JKJaeyoung Kim
Jaeyoung Kim
Hanhoon ParkHanhoon Park
Hanhoon Park
JPJong-Il Park
Jong-Il Park

10 December 2020 in IEEE Access
Verified
Journal Article
Open access
SKSeungwon Kim
Seungwon Kim
AJAllison Jing
Allison Jing
Hanhoon ParkHanhoon Park
Hanhoon Park
Gun LeeGun Lee
Gun Lee
Weidong HuangWeidong Huang
Weidong Huang
MBMark Billinghurst
Mark Billinghurst
In collaboration systems, collaborators often use hand gestures for showing information relating to a distant object. However, in viewer’s perspective, it is sometimes difficult to know where the conventional gesture cue (Hands-in-Air style: HiA) refers to because the conventional HiA gesture appears away from the distant object. In this paper, we investigate how two factors, distance to the object and view angle difference between collaborators, influence the understanding of HiA gesture by comparing the use of it at 25 positions with 5 distances and 5 view angles. In a user study, we found that the distance to the target object and view angle difference negatively influenced HiA gesture communication. The influence of the distance and view angle was more serious between smaller angles (0 ~ 30 degree) than larger angles (30 ~ 60 degree), and between shorter distances (1m ~ 1.5m) than between longer distance (1.5m ~ 2m). As a solution, we propose the Hands-on-Target (HoT) style which positions the hand gesture cue on the surface of the target object. The HoT style gesture cue dramatically reduces the negative effect of the distance and view angle difference. Participants completed the task 29.3 percent faster, selected the correct object 2.75 times more, and felt 63.1 percent less mental effort. For further investigation, we discuss on the extensibility of the HoT interface that it can be used not only for object selection but also for diverse type of gesture communication including gesture for object manipulation because the HoT interface can support all possible real world hand gestures.

12 June 2019 in Electronics
Verified
Journal Article
Open access
PDF file
JLJean-Pierre Lomaliza
Jean-Pierre Lomaliza
Hanhoon ParkHanhoon Park
Hanhoon Park
Newtonian reaction to blood influx into the head at each heartbeat causes subtle head motion at the same frequency as the heartbeats. Thus, this head motion can be used to estimate the heart rate. Several studies have shown that heart rates can be measured accurately by tracking head motion using a desktop computer with a static camera. However, implementation of vision-based head motion tracking on smartphones demonstrated limited accuracy due to the hand-shaking problem caused by the non-static camera. The hand-shaking problem could not be handled effectively with only the frontal camera images. It also required a more accurate method to measure the periodicity of noisy signals. Therefore, this study proposes an improved head-motion-based heart-rate monitoring system using smartphones. To address the hand-shaking problem, the proposed system leverages the front and rear cameras available in most smartphones and dedicates each camera to tracking facial features that correspond to head motion and background features that correspond to hand-shaking. Then, the locations of facial features are adjusted using the average point of the background features. In addition, a correlation-based signal periodicity computation method is proposed to accurately separate the true heart-rate-related component from the head motion signal. The proposed system demonstrates improved accuracy (i.e., lower mean errors in heart-rate measurement) compared to conventional head-motion-based systems, and the accuracy is sufficient for daily heart-rate monitoring.

22 October 2016 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
JLJean-Pierre Lomaliza
Jean-Pierre Lomaliza
Hanhoon ParkHanhoon Park
Hanhoon Park

1 January 2013 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
JSJoongseok Song
Joongseok Song
JPJungsik Park
Jungsik Park
Hanhoon ParkHanhoon Park
Hanhoon Park
JPJong-Il Park
Jong-Il Park
We describe and evaluate a practical approach for implementing computer-generated-holography (CGH) using multiple graphic processing units (GPUs). The proposed method can generate high-definition (HD) resolution (1920×1080) digital holograms in real-time. In order to demonstrate the plausibility of our method, some experimental results will be given. First, we discuss the advantage of GPUs for CGH against central processing units (CPUs) by comparing the performance of both. Our results show that use of GPUs can shorten CGH computation time by 2791 times. Then, we discuss the potential of multiple GPUs for generating HD resolution digital holograms in real-time by measuring and analyzing the CGH computational time in accordance with the number of GPUs. Our result shows that the CGH computational time decreases nonlinearly, with a logarithmic-like curve, as the number of GPU increases. Therefore, we can determine the number of GPUs to maximize the efficiency. Consequently, our implementation can generate HD resolution digital holograms at a rate of more than 66 hps (holograms-per-second) using two NVIDIA GTX 590 cards.

1 May 2020 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
SKSanghoon Kang
Sanghoon Kang
Hanhoon ParkHanhoon Park
Hanhoon Park
JPJong-Il Park
Jong-Il Park