Sudarshan Ragunathan

Dr. Sudarshan Ragunathan

Barrow Neurological Institute
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PHPetra J. van Houdt
Petra J. van Houdt
SRSudarshan Ragunathan
Sudarshan Ragunathan
MBMichael Berks
Michael Berks
ZAZaki Ahmed
Zaki Ahmed
LKLucy Kershaw
Lucy Kershaw
OGon behalf of the ISMRM Perfusion Study Group
on behalf of the ISMRM Perfusion Study Group
Purpose: Software has a substantial impact on quantitative perfusion MRI values. The lack of generally accepted implementations, code sharing and transparent testing reduces reproducibility, hindering the use of perfusion MRI in clinical trials. To address these issues, the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI) aimed to establish a community‐led, centralized repository for sharing open‐source code for processing contrast‐based perfusion imaging, incorporating an open‐source testing framework.Methods: A repository was established on the OSIPI GitHub website. Python was chosen as the target software language. Calls for code contributions were made to OSIPI members, the ISMRM Perfusion Study Group, and publicly via OSIPI websites. An automated unit‐testing framework was implemented to evaluate the output of code contributions, including visual representation of the results.Results: The repository hosts 86 implementations of perfusion processing steps contributed by 12 individuals or teams. These cover all core aspects of DCE‐ and DSC‐MRI processing, including multiple implementations of the same functionality. Tests were developed for 52 implementations, covering five analysis steps. For T1 mapping, signal‐to‐concentration conversion and population AIF functions, different implementations resulted in near‐identical output values. For the five pharmacokinetic models tested (Tofts, extended Tofts‐Kety, Patlak, two‐compartment exchange, and two‐compartment uptake), differences in output parameters were observed between contributions.Conclusions: The OSIPI DCE‐DSC code repository represents a novel community‐led model for code sharing and testing. The repository facilitates the re‐use of existing code and the benchmarking of new code, promoting enhanced reproducibility in quantitative perfusion imaging.

20 July 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
Ashley StokesAshley Stokes
Ashley Stokes
SRSudarshan Ragunathan
Sudarshan Ragunathan
RRRyan K. Robison
Ryan K. Robison
AFAlberto Fuentes
Alberto Fuentes
LBLaura C. Bell
Laura C. Bell
CQC. Chad Quarles
C. Chad Quarles


1 December 2011
Verified
Conference Paper
Closed access
SRSudarshan Ragunathan
Sudarshan Ragunathan
DFDavid Frakes
David Frakes
KPKelvin Peng
Kelvin Peng
WSWilliam Singhose
William Singhose
Human operators have difficulty driving cranes quickly, accurately, and safely because of the slow response of heavy crane structures, non-intuitive control interfaces, and payload oscillations. This paper presents a new type of interface that allows operators to drive a crane by moving a hand-held radio-frequency tag. Real-time location sensors are used to track the movements of the tag and the tag position is used in a feedback control loop to drive the crane. An input shaper is added to eliminate dangerous payload oscillations. Unfortunately, significant sensor noise can increase the energy-usage and settling-time during operation. To reduce these negative side effects, several filters are used on experimentally-acquired tag trajectories. The filtered trajectories are then used to drive crane simulations. The filter performance is evaluated with respect to the energy usage of the crane trolley, and the settling time of the crane payload oscillations. The effects of filter window lengths on these parameters are also investigated.

5 May 2021 in Tomography
Verified
Journal Article
Open access
PDF file
SRSudarshan Ragunathan
Sudarshan Ragunathan
LBLaura C. Bell
Laura C. Bell
NSNatenael Semmineh
Natenael Semmineh
Ashley StokesAshley Stokes
Ashley Stokes
JSJeremy M. Shefner
Jeremy M. Shefner
Chad QuarlesChad Quarles
Chad Quarles
(1) Background: This work characterizes the sensitivity of magnetic resonance-based Relaxivity Contrast Imaging (RCI) to Amyotrophic Lateral Sclerosis (ALS)-induced changes in myofiber microstructure. Transverse Relaxivity at Tracer Equilibrium (TRATE), an RCI-based parameter, was evaluated in the lower extremities of ALS patients and healthy subjects. (2) Methods: In this IRB-approved study, 23 subjects (12 ALS patients and 11 healthy controls) were scanned at 3T (Philips, The Netherlands). RCI data were obtained during injection of a gadolinium-based contrast agent. TRATE, fat fraction and T2 measures, were compared in five muscle groups of the calf muscle, between ALS and control populations. TRATE was also evaluated longitudinally (baseline and 6 months) and was compared to clinical measures, namely ALS Functional Rating Scale (ALSFRS-R) and Hand-Held Dynamometry (HHD), in a subset of the ALS population. (3) Results: TRATE was significantly lower (p < 0.001) in ALS-affected muscle than in healthy muscle in all muscle groups. Fat fraction differences between ALS and healthy muscle were statistically significant for the tibialis anterior (p = 0.01), tibialis posterior (p = 0.004), and peroneus longus (p = 0.02) muscle groups but were not statistically significant for the medial (p = 0.07) and lateral gastrocnemius (p = 0.06) muscles. T2 differences between ALS and healthy muscle were statistically significant for the tibialis anterior (p = 0.004), peroneus longus (p = 0.004) and lateral gastrocnemius (p = 0.03) muscle groups but were not statistically significant for the tibialis posterior (p = 0.06) and medial gastrocnemius (p = 0.07) muscles. Longitudinally, TRATE, averaged over all patients, decreased by 28 ± 16% in the tibialis anterior, 47 ± 18% in the peroneus longus, 25 ± 19% in the tibialis posterior, 29 ± 14% in the medial gastrocnemius and 35 ± 18% in the lateral gastrocnemius muscles between two timepoints. ALSFRS-R scores were stable in two of four ALS patients. HHD scores decreased in three of four ALS patients. (4) Conclusion: RCI-based TRATE was shown to consistently differentiate ALS-affected muscle from healthy muscle and also provide a quantitative measure of longitudinal muscle degeneration.

17 October 2012
Verified
Conference Paper
Closed access
PDF file
SRSudarshan Ragunathan
Sudarshan Ragunathan
DFDavid Frakes
David Frakes
KPKelvin Peng
Kelvin Peng
LSLee Stokes
Lee Stokes
WSWilliam Singhose
William Singhose
A novel hand-motion crane control system was developed that improves performance by providing: 1) an intuitive control interface and 2) an element that reduces the complex oscillatory behavior of the payload. Hand-motion control allows operators to drive a crane by simply moving a hand-held radio-frequency tag through the desired path. Real-time location sensors track the movements of the tag and its position is used in a feedback-loop to drive the crane. However, tag measurements are corrupted by noise. It is important to understand the noise properties so that appropriate filters can be designed to mitigate the effects of noise and improve tracking accuracy. This paper quantifies the measurement noise for two possible situations during hand-motion control: when the tag is 1) located in open space inside the sensor coverage zone, and 2) is placed near large machinery. This paper also presents a Kalman filter that adapts to the noise characteristics of the workspace to minimize the tag-tracking error.