This paper applies the emerging hybrid active third-harmonic current injection converter (H3C) to the battery energy storage system (BESS), forming a novel H3C-BESS structure. Compared with the commonly used two-stage VSC-BESS, the proposed H3C-BESS has the capability to reduce the passive components and switching losses. The operation principle of the H3C-BESS is analyzed and the mathematical model is derived. The closed-loop control strategy and controller design are proposed for different operation modes of the system, which include the battery current/voltage control and the injected harmonic current control. In particular, active damping control is realized through the grid current control, which could suppress the LC-filter resonance without the need of passive damping resistors. Simulation results show that the proposed topology and its control strategy have fast dynamic response, with a setup time of less than 4 ms. In addition, the total harmonic distortions of battery current and grid currents are only 2.54% and 3.15%, respectively. The amplitude of the injected harmonic current is only half of the grid current, indicating that the current injection circuit generates low losses. Experimental results are also provided to verify the validity of the proposed solution.
The traditional secondary control method for virtual synchronous generators suffers from limitations such as slow dynamic response and poor adaptability under varying operating conditions, which significantly affect the reliability and stability of microgrids. To address these issues, this paper proposes an adaptive virtual synchronous generator secondary control method for microgrids based on predefined-time convergence. First, a predefined-time controller is designed, whose convergence time can be preset by the user, thereby resolving the problem of excessively long convergence times for frequency regulation and power sharing. Second, an adaptive inertia damping control method incorporating Gaussian functions is introduced to mitigate frequency fluctuations during disturbances in the microgrid system, effectively suppressing frequency deviations and enhancing microgrid stability. Finally, based on Lyapunov stability theory, the convergence of the proposed control method is rigorously proved, and its feasibility is validated through MATLAB/Simulink simulations. The results demonstrate that the proposed secondary control method reduces the frequency and active power convergence times by 0.98 s and 0.49 s, respectively, compared to traditional virtual synchronous generator secondary control methods. Additionally, it exhibits smaller frequency fluctuation magnitude during disturbances, enabling fast and smooth frequency recovery.
In residential photovoltaic (PV) energy storage systems, the bidirectional DC–DC converter between the DC bus and the battery must operate efficiently over wide input- and output-voltage ranges. This paper presents the design and implementation of a high-gain bidirectional CLLC resonant converter rated for 4.8 kW. The converter operating principle under pulse frequency modulation (PFM) is described, and its voltage gain is derived using first harmonic approximation (FHA). Resonant tank parameter selection considers voltage gain, soft switching, and gain monotonicity. To improve modulation accuracy and coordinate register updates under PFM, a high-precision implementation based on high-resolution pulse-width modulation (HRPWM) is proposed. Global loading synchronizes supported PWM shadow registers, while high-resolution period updates are coordinated separately. A converter loss model guides the forced-air cooling design of a parallel-fin heatsink, assessed by electrothermal co-simulation at 6 kW output power and long-duration tests at 4.8 kW battery-port power. Experimental results show that the peak efficiency of the prototype reaches 97.45% in charging mode and 96.66% in discharging mode.