Felipe Wilker Grillo

Dr. Felipe Wilker Grillo

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2018 in 3D Printing in Medicine
Verified
Journal Article
Open access
PDF file
FGFelipe Wilker Grillo
Felipe Wilker Grillo
Victor SouzaVictor Souza
Victor Souza
RMRenan Hiroshi Matsuda
Renan Hiroshi Matsuda
CRCarlo Rondinoni
Carlo Rondinoni
Theo PavanTheo Pavan
Theo Pavan
ACAntonio Adilton Oliveira Carneiro
Antonio Adilton Oliveira Carneiro
Training in medical education depends on the availability of standardized materials that can reliably mimic the human anatomy and physiology. One alternative to using cadavers or animal bodies is to employ phantoms or mimicking devices. Styrene-ethylene/butylene-styrene (SEBS) gels are biologically inert and present tunable properties, including mechanical properties that resemble the soft tissue. Therefore, SEBS is an alternative to develop a patient-specific phantom, that provides real visual and morphological experience during simulation-based neurosurgical training. A 3D model was reconstructed and printed based on patient-specific magnetic resonance images. The fused deposition of polyactic acid (PLA) filament and selective laser sintering of polyamid were used for 3D printing. Silicone and SEBS materials were employed to mimic soft tissues. A neuronavigation protocol was performed on the 3D-printed models scaled to three different sizes, 100%, 50%, and 25% of the original dimensions. A neurosurgery team (17 individuals) evaluated the phantom realism as “very good” and “perfect” in 49% and 31% of the cases, respectively, and rated phantom utility as “very good” and “perfect” in 61% and 32% of the cases, respectively. Models in original size (100%) and scaled to 50% provided a quantitative and realistic visual analysis of the patient’s cortical anatomy without distortion. However, reduction to one quarter of the original size (25%) hindered visualization of surface details and identification of anatomical landmarks. A patient-specific phantom was developed with anatomically and spatially accurate shapes, that can be used as an alternative for surgical planning. Printed models scaled to sizes that avoided quality loss might save time and reduce medical training costs.

29 January 2021 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
MAMehran Azimbagirad
Mehran Azimbagirad
FGFelipe Wilker Grillo
Felipe Wilker Grillo
YHYaser Hadadian
Yaser Hadadian
ACAntonio Adilton Oliveira Carneiro
Antonio Adilton Oliveira Carneiro
LMLuiz Murta
Luiz Murta
<!-- *** Custom HTML *** --> Purpose: Brain image volumetric measurements (BVM) methods have been used to quantify brain tissue volumes using magnetic resonance imaging (MRI) when investigating abnormalities. Although BVM methods are widely used, they need to be evaluated to quantify their reliability. Currently, the gold-standard reference to evaluate a BVM is usually manual labeling measurement. Manual volume labeling is a time-consuming and expensive task, but the confidence level ascribed to this method is not absolute. We describe and evaluate a biomimetic brain phantom as an alternative for the manual validation of BVM. Methods: We printed a three-dimensional (3D) brain mold using an MRI of a three-year-old boy diagnosed with Sturge-Weber syndrome. Then we prepared three different mixtures of styrene-ethylene/butylene-styrene gel and paraffin to mimic white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF). The mold was filled by these three mixtures with known volumes. We scanned the brain phantom using two MRI scanners, 1.5 and 3.0 Tesla. Our suggestion is a new challenging model to evaluate the BVM which includes the measured volumes of the phantom compartments and its MRI. We investigated the performance of an automatic BVM, i.e., the expectation–maximization (EM) method, to estimate its accuracy in BVM. Results: The automatic BVM results using the EM method showed a relative error (regarding the phantom volume) of 0.08, 0.03, and 0.13 (±0.03 uncertainty) percentages of the GM, CSF, and WM volume, respectively, which was in good agreement with the results reported using manual segmentation. Conclusions: The phantom can be a potential quantifier for a wide range of segmentation methods.

9 November 2026 in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
Verified
Journal Article
Closed access
BBBruna Lara Berzaghi
Bruna Lara Berzaghi
TGTiago Giraldi
Tiago Giraldi
FJFrancisco Carlos Specian Junior
Francisco Carlos Specian Junior
FGFelipe Wilker Grillo
Felipe Wilker Grillo
DCDario Cecilio-Fernandes
Dario Cecilio-Fernandes
TSThiago Martins Santos
Thiago Martins Santos
Introduction: Simulation-based education is essential for developing procedural competence in ultrasound-guided thoracentesis (USGT). However, few USGT phantoms integrate objective metrics to assess cognitive workload. This study used eye tracking (ET) to quantify cognitive demand and establish preliminary validity evidence for a novel, anatomically variable USGT phantom. Materials and Methods: Thirteen experienced clinicians performed simulated USGT on a modular phantom divided into 4 quadrants of increasing difficulty. Eye-tracking glasses recorded gaze behaviour across 2 areas of interest: the ultrasound monitor and the phantom. Cognitive workload was assessed through fixation and revisitation counts. Postsimulation, participants completed a Likert-scale questionnaire and provided qualitative feedback. Results: The monitor elicited significantly more fixations than the phantom [[91.6 ± 12.4 vs. 38.8 ± 12.4; F(1,87.1) = 20.26, P < 0.001], particularly in the most complex quadrant (Q3). Revisitation counts trended higher on the monitor but were not statistically significant overall ( P = 0.08); however, Q3 showed significantly more revisitations than Q4 ( P = 0.01). Q3 also required the most puncture attempts (2.31 ± 0.40; P = 0.001), aligning with increased cognitive workload. Realism and educational usefulness received high ratings (24/30 and 14.1/15, respectively). Thematic analysis highlighted anatomic fidelity, graduated difficulty, and integration of image acquisition with needle guidance as key strengths. ET revealed quadrant-specific variations in cognitive workload, demonstrating the phantom's structural design potential for progressive, scaffolded training. Fixation and revisitation metrics provided response process validity evidence, linking gaze behaviour to task complexity. Expert feedback confirmed the phantom’s realism and educational value, reinforcing its feasibility as a platform for structured, just-in-time training. Conclusion: ET offers a powerful lens to evaluate cognitive demands in procedural simulation. This study demonstrates how gaze metrics can inform phantom design and assessment, enhancing the fidelity and effectiveness of USGT training.

4 June 2019
Verified
Book Chapter
Closed access
PDF file
FGFelipe Wilker Grillo
Felipe Wilker Grillo
CRC. Rondinoni
C. Rondinoni
AFA. C. S. S. Filho
A. C. S. S. Filho
FSF. H. Simozo
F. H. Simozo
JFJ. A. Farina
J. A. Farina
ACA. A. O. Carneiro
A. A. O. Carneiro