Miho Seike

Dr. Miho Seike

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
MSMiho Seike
Miho Seike
NKNobuyoshi Kawabata
Nobuyoshi Kawabata
MHMasato Hasegawa
Masato Hasegawa

1 April 2017 in Safety Science
Verified
Journal Article
Closed access
MSMiho Seike
Miho Seike
NKNobuyoshi Kawabata
Nobuyoshi Kawabata
MHMasato Hasegawa
Masato Hasegawa

1 July 2017 in Fire Safety Journal
Verified
Journal Article
Closed access
MSMiho Seike
Miho Seike
NKNobuyoshi Kawabata
Nobuyoshi Kawabata
MHMasato Hasegawa
Masato Hasegawa

1 March 2019 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
MSMiho Seike
Miho Seike
NKNobuyoshi Kawabata
Nobuyoshi Kawabata
MHMasato Hasegawa
Masato Hasegawa
TKTaisuke Kobayashi
Taisuke Kobayashi

1 October 2019 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MSMiho Seike
Miho Seike
NKNobuyoshi Kawabata
Nobuyoshi Kawabata
MHMasato Hasegawa
Masato Hasegawa
HTHirato Tanaka
Hirato Tanaka

8 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
PTPOWEI TUNG
POWEI TUNG
CHChung Hung-Chieh
Chung Hung-Chieh
NKNobuyoshi Kawabata
Nobuyoshi Kawabata
MSMiho Seike
Miho Seike
MHMasato Hasegawa
Masato Hasegawa
TSTzu-Sheng Shen
Tzu-Sheng Shen
Japan and Europe have adopted significantly different ventilation modes with regard to traffic conditions (with or without congestion). This study focuses on the smoke behavior of different ventilation modes by conducting a 3D CFD analysis of smoke distribution and CO concentration variation and then comparing these modes based on two groups (relatively low target velocity: 0 and 1 m/s; relatively high target velocity: 2 and 3 m/s). The considered fire size is 30 MW for four longitudinal gradients (0, 2, 4, and 6%). In the simulation results, velocities of both 0 and 1 m/s reveal good performance in maintaining the stratification of smoke and ensuring the safety of the environment in 10 min in the occurrence of traffic jams. However, in 15 min, the smoke conditions change. Thus, it is difficult to distinguish which ventilation mode (0 and 1 m/s) shows relatively better performance during traffic congestion. When traffic is uncongested, the comparison of Um = 2 and 3 m/s reveals that a target velocity of Um = 2 m/s (lower than critical velocity) can also prevent the risk of smoke on the upstream side because no descending phenomenon is observed. Moreover, Um = 2 m/s causes the relatively slow propagation of descending smoke, increasing the possibility of evacuation once a second traffic incident occurs on the downstream side of the fire source.