Elwin Vrouwe

Dr. Elwin Vrouwe


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2017 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
MVMartina Viefhues
Martina Viefhues
SSShiwen Sun
Shiwen Sun
DVDonya Valikhani
Donya Valikhani
BNBernd Nidetzky
Bernd Nidetzky
EVElwin Vrouwe
Elwin Vrouwe
Juan M. BolivarJuan M. Bolivar
Juan M. Bolivar
Flow microreactors utilizing immobilized enzymes are of great interest in biocatalysis development. Most of the common devices are permanently closed, single-use systems, which allow limited physical and chemical surface modifications and evaluation methods. In this paper we will present resealable flowcells that overcome these limitations and moreover allow a quick and easy integration of sensor systems, because of the use of modular building blocks. The devices were utilized to study the enzyme activity of glucose oxidase immobilized on chemically modified glass surfaces under flow conditions, employing integrated optical oxygen sensors for on-line monitoring.

2 May 2025 in Science Advances
Verified
Journal Article
Open access
EPElsa Perez-Martin
Elsa Perez-Martin
TBTristan Beranger
Tristan Beranger
LBLaurent Bonnet
Laurent Bonnet
FTFrederic Teppe
Frederic Teppe
ALAlvydas Lisauskas
Alvydas Lisauskas
JTJeremie Torres
Jeremie Torres
Electrodynamic interactions between biomolecules are of potential biological interest for temporal and spatial molecular controls, warranting investigation of their activation through various mechanisms in living systems. Using a light-harvesting protein in the phycobilisome antenna system of red algae, we proved that not only light exposure but also thermal energy alone can trigger attractive electrodynamic interactions up to hundreds of nanometers, sustained by low-frequency collective modes. Activation of such modes and interactions might influence conformational rearrangements and energy transport within the phycobilisome system. This paradigm shift underscores the immense potential of biological systems in exploiting different forms of energy to achieve optimal energy transfer.

8 October 2010 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
GPG. O. F. Parikesit
G. O. F. Parikesit
EVElwin Vrouwe
Elwin Vrouwe
MBM. T. Blom
M. T. Blom
JWJ. Westerweel
J. Westerweel
We present our observation of meta-hydrophobicity, where geometrically patterned surfaces make hydrophilic microchannels exhibit hydrophobic-like behaviors. We analyze the wetting-induced energy decrease that results from the surface geometries and experimentally demonstrate how those geometries can modulate the dynamics of capillary-driven wetting and evaporation-driven drying of microfluidic systems. Our results also show that the modulated wetting dynamics can be employed to generate regulated patterns of microbubbles.

1 December 2017 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
RCR R Carvalho
R R Carvalho
SRS Reuvekamp
S Reuvekamp
HZH Zuilhof
H Zuilhof
MBM T Blom
M T Blom
EVElwin Vrouwe
Elwin Vrouwe
Low-temperature bonding of glass substrates is of great interest in the field of microfluidic-based biosensing, and we study how laser welding could be used for this. This technology allows for the modification of glass channels with temperature-sensitive materials prior to bonding. We study the effects of the welding process by investigation of the thermal degradation of a biotin monolayer and whether it retains the ability to conjugate with fluorescently-labelled streptavidin.

1 January 2018 in Frontiers in Cellular Neuroscience
Verified
Journal Article
Open access
TPThomas Pauwelyn
Thomas Pauwelyn
BMBeatrice Miccoli
Beatrice Miccoli
AVAravinthan Velnayagam
Aravinthan Velnayagam
RBRobert Jan Boom
Robert Jan Boom
MSMaciej Skolimowski
Maciej Skolimowski
VRVeerle Reumers
Veerle Reumers
High-throughput screening is essential for current pharmaceutical drugs development where the number of target compounds to be screened is in the range of 105 – 106 trials and constantly increasing (Macarron et al., 2011). Specifically, cardiotoxicity is one of the main causes of drug rejection and withdrawal from the market. Additionally, current in vitro research based on animal models does not truly predict the response of the human heart (Mathur et al., 2015). Multi-electrodes arrays (MEAs) represent a powerful tool for in vitro electrophysiological studies of both animal or human cardiac models. They allow non-invasive and long-term monitoring of cardiac action potentials, including both extra- and intra-cellular recordings. Therefore, they represent an effective strategy for high-throughput and high-resolution cardiotoxicity studies. To further increase the throughput of MEAs, microfluidic devices can separate the surface of chips into multiple, independent cell culture chambers. Microfluidic devices enable parallelization and automation as well as the reduction of reagents and cell consumption. This leads to a decrease in the final cost of the assay. Nevertheless, the integration of microfluidics on complementary metal-oxide semiconductors (CMOS) integrated circuits presents numerous technological challenges that need to be thoroughly assessed and faced (Huang and Mason, 2013). To overcome these challenges, we developed a novel strategy to integrate a polystyrene (PS)-based microfluidic system on top of a CMOS MEA (Lopez et al., 2018). A thin perforated glass interposer was bonded onto the CMOS MEA, while the PS-based microfluidic system was glued on top. The PS-device determined the height of the microfluidic chamber and their locations. The microfluidic chip separated the chip surface into 16 independent cell culture chambers. Therefore, up to 16 different experiment conditions are possible per device. The microfluidic cell culture chambers (area 0.62 mm^2, height 1.25 mm) are addressed by an individual inlet and an individual outlet. Each chamber contains 1,024 recording electrodes that are grounded by on-chip integrated reference electrodes. Therefore, no external reference electrodes were required. The electrodes in each chamber are independently addressable for individual measurements. The chip architecture allows for 6 different types of measurements on the same chips: extracellular recordings, intracellular recording, constant voltage stimulation, constant current stimulation, impedance monitoring at a fixed frequency and impedance spectroscopy between 10 Hz and 1 MHz (Lopez et al., 2018). At first, we optimized the protocol for the microfluidic culture of rat ventricular cardiomyocytes in prototype devices. In the first-generation prototypes, the CMOS MEA chip was replaced with a transparent glass slide for easier optical access. External syringe pumps controlled the perfusion of fluids through the microfluidic chambers. Flow rates were optimized for each of the steps of the cell culture, including sterilization, coating, seeding, and nutrients delivery. Cardiomyocytes were successfully cultured for up to 9 days in vitro (DIV). Cardiac functionality was confirmed both by visualizing cardiac contractions using phase-contrast microscopy and by lens-free imaging for in situ monitoring. Cell viability was assessed through calcein and Hoechst stainings. Specifically, from the fluorescent staining a cell density of 1640 ± 280 nuclei/mm^2 was measured inside the microfluidic chambers at 2 DIV. In the second-generation prototypes, the glass slide was replaced with a passive high-density MEA. The optimized protocol for culturing microfluidic cardiac cell cultures was successfully transferred and clear extracellular recordings were detected in the electrodes of size 11x11 µm^2 from DIV 3 – 5. An average peak-to-peak voltage amplitude of 601 ± 16 µV was measured at 4 DIV with a beating rate of 51.5 ± 1.1 bpm. Therefore, the presented approach is compatible with Si-based MEAs. Currently, the optimized protocols developed in the prototype device are being applied to a microfluidic system integrated onto the CMOS MEA substrate. As syringe pumps are bulky and not scalable, they will be replaced by embedded peristaltic pumps to internally control the fluids flows. Human induced pluripotent stem-cells will be then used to assess drug toxicity assays exploiting the high-throughput 16 wells configuration. Our approach is compatible with the 96 well plate standard. Moreover, both the number of CMOS MEAs and of microfluidic chambers per system can be extended so to further increase the throughput and reach a 96 wells configuration.

25 November 2025 in Reaction Chemistry & Engineering
Verified
Journal Article
Closed access
PDF file
NCNicolette Czarnievicz
Nicolette Czarnievicz
EVElwin Vrouwe
Elwin Vrouwe
CCCecilia Córdoba-Quintero
Cecilia Córdoba-Quintero
MSMaciej Skolimowski
Maciej Skolimowski
Fernando Lopez-GallegoFernando Lopez-Gallego
Fernando Lopez-Gallego
Microfluidics is a very attractive discipline for implementing more versatile high-throughput screening methods to improve enzymes. However, state-of-the-art microfluidics set-ups are mainly devoted to screening enzymes in solution, while screening of enzyme immobilisation protocols using microfluidics is scarce. In this work, we develop a versatile wall-coated microreactor (WCμR) plate for transaminase screening, integrating up to 32 poly(methyl methacrylate) (PMMA) WCμR functionalised with different metal chelates. The device is validated by screening His-tagged and His-clustered amine transaminase (ATA) variants that result in different orientations, evaluating a total of 30 unique biocatalyst-functionalisation combinations for activity, stability, and immobilisation efficiency. In batch mode reactions, H3A, H2A, and H4 ATA variants from Pseudomonas fluorescens, Chromobacterium violaceum, and Haelomonas elongata, respectively, immobilised on copper-chelates exhibit the highest scores based on fluorometer assays. This WCμR plate can be easily integrated with optical microscopes for spatiotemporal assays. Alternatively, these WCμRs are readily adapted for continuous biotransformation operating as flow microreactors. This capability is tested with a His-tagged ATA immobilised on the microchannels to continuously aminate 5-hydroxymethyl furfural, achieving a specific productivity of 0.49 molHMFA molATA −1 s−1 and a total turnover number of 9 × 103, with a maximum space–time yield (STY) of 0.077 g L−1 d−1. This study highlights the potential of WCμRs for high-throughput enzyme screening and continuous biocatalysis, offering precise control over reaction conditions.