Marco Xavier Rivera González

Dr. Marco Xavier Rivera González

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MGMarco Xavier Rivera González
Marco Xavier Rivera González
NFNazario Felix
Nazario Felix
ILIsabel López
Isabel López
JZJuan Sebastián Ochoa Zambrano
Juan Sebastián Ochoa Zambrano
AMAndrés Miranda-Martínez
Andrés Miranda-Martínez
CMceferino maestu
ceferino maestu
A novel compact device with spectrum analyzer characteristics has been designed, which allows the measuring of the maximum power received in multiple narrow frequency bands of 300 kHz, recording the entire spectrum from 78 MHz to 6 GHz; the device is capable of measuring the entire communications spectrum and detecting multiple sources of electromagnetic fields using the same communications band. The proposed device permits the evaluation of the cross-talk effect that, in conventional exposimeters, generates a mistake estimation of electromagnetic fields. The device was calibrated in an anechoic chamber for far-fields and was validated against a portable spectrum analyzer in a residential area. A strong correlation between the two devices with a confidence higher than 95% was obtained; indicating that the device could be considered as an important tool for electromagnetic field studies.

13 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AMAndrés Miranda-Martínez
Andrés Miranda-Martínez
MGMarco Xavier Rivera González
Marco Xavier Rivera González
MZMichael Zeinoun
Michael Zeinoun
LCLuis Carvajal-Ahumada
Luis Carvajal-Ahumada
JOJose Javier Serrano Olmedo
Jose Javier Serrano Olmedo
Viscosity variation in human fluids, such as Synovial Fluid (SF) or Cerebrospinal Fluid (CSF), can be used as a diagnostic factor; however, the sample volume obtained for analysis is usually small, making it difficult to measure its viscosity. On the other hand, Quartz Crystal Resonators (QCR) have been used widely in sensing applications due to their accuracy, cost, and size. This work provides the design and validation of a new viscosity measurement system based on quartz crystal resonators for low volume fluids, leading to the development of a sensor called “ViSQCT” as a prototype for a new medical diagnostic tool. The proposed method is based on measuring the resonance frequency at the crystal’s maximum conductance point through a frequency sweep, where crystals with 10 MHz fundamental resonance frequency were used. For validation purposes, artificial fluids were developed to simulate SFs and CFs in healthy and pathological conditions as experiment phantoms. A commercial QCR based system was also used for validation since its methodology differs from ours. A conventional rotational viscometer was used as a reference for calibration purposes. ViSQCT demonstrates the capability to measure the sample’s viscosity differentiation between healthy and pathological fluid phantoms and shows that it can be used as a basis for a diagnostic method of several pathologies related to the studied biological fluids. However, some performance differences between both QCR-based systems compared to the reference system deserves further investigation.

22 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
LCLuis Carvajal
Luis Carvajal
MGMarco Xavier Rivera González
Marco Xavier Rivera González
OSOscar Leonardo Herrera Sandoval
Oscar Leonardo Herrera Sandoval
JOJose Javier Serrano Olmedo
Jose Javier Serrano Olmedo
The main objective of this article is to demonstrate through experimental means the capacity of the quartz crystal resonator (QCR) to characterize biological samples of aqueous dilutions of hyaluronic acid according to their viscosity and how this capacity may be useful in the potential diagnosis of arthritic diseases. The synovial fluid is viscous due to the presence of hyaluronic acid, synthesized by synovial lining cells (type B), and secreted into the synovial fluid thus making the fluid viscous. In consequence, aqueous dilutions of hyaluronic acid may be used as samples to emulate the synovial fluid. Due to the viscoelastic and pseudo-plastic behavior of hyaluronic acid, it is necessary to use the Rouse model in order to obtain viscosity values comparable with viscometer measures. A Fungilab viscometer (rheometer) was used to obtain reference measures of the viscosity in each sample in order to compare them with the QCR prototype measures.

Verified
Journal Article
Open access
PDF file
ILIsabel López
Isabel López
MGMarco Xavier Rivera González
Marco Xavier Rivera González
CMceferino maestu
ceferino maestu
Since the establishment of regulations for exposure to extremely low-frequency (0–300) Hz electromagnetic fields, scientific opinion has prioritised the hypothesis that the most important parameter determining cellular behaviour has been intensity, ignoring the other exposure parameters (frequency, time, mode, waveform). This has been reflected in the methodologies of the in vitro articles published and the reviews in which they are included. A scope review was carried out, grouping a total of 79 articles that met the proposed inclusion criteria and studying the effects of the different experiments on viability, proliferation, apoptosis, oxidative stress and the cell cycle. These results have been divided and classified by frequency, intensity, exposure time and exposure mode (continuous/intermittent). The results obtained for each of the processes according to the exposure parameter used are shown graphically to highlight the importance of a good methodology in experimental development and the search for mechanisms of action that explain the experimental results, considering not only the criterion of intensity. The consequence of this is a more than necessary revision of current exposure protection regulations for the general population based on the reductionist criterion of intensity.

8 March 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
MGMarco Xavier Rivera González
Marco Xavier Rivera González
IMIsabel López de Mingo
Isabel López de Mingo
ARAlexandra Amuneke Ramírez
Alexandra Amuneke Ramírez
CUCeferino Maestú Unturbe
Ceferino Maestú Unturbe
In vitro studies requiring controlled exposure to low-frequency electromagnetic fields employ exposure systems with different geometries and configurations, the Helmholtz configuration being one of the most widely used. This configuration has limitations in the homogeneity of the spatial distribution of the magnetic field intensity values. We present the design, manufacturing, and characterisation of a new coil system, called RILZ configuration, which improves the distribution of magnetic field intensity values in the three dimensions of space for three different heights in comparison with the traditional circular coils in Helmholtz configuration. In addition, a comparative study of the cellular response in CT2A cultures exposed to a magnetic field of 50 Hz and 100 µT for 48 hrs is performed with both exposure systems. The results of the study show reduced values of deviation from the central value of magnetic field intensity using the RILZ coil system. These differences are statistically significant compared to the Helmholtz configuration for the three Cartesian directions: x (p < 0.01), y (p < 0.01), z (p < 0.01). In addition, the intensity values for three different heights are statistically significantly correlated using the RILZ coil system (p < 0.01). The differences in cell behaviour are also statistically significant between the two systems (p < 0.01) and may be directly related to the differences found in the distribution of intensity values between the two systems. This study highlights the importance of the homogeneity of the magnetic field intensity generated by the exposure systems used and offers an effective solution to control the magnetic field exposure parameters in vitro assays.

Verified
Journal Article
Open access
PDF file
ILIsabel López
Isabel López
MGMarco Xavier Rivera González
Marco Xavier Rivera González
MRMilagros Ramos
Milagros Ramos
CMceferino maestu
ceferino maestu
The involvement of magnetic fields in basic cellular processes has been studied for years. Most studies focus their results on a single frequency and intensity. Intensity has long been the central parameter in hypotheses of interaction between cells and magnetic fields; however, frequency has always played a secondary role. The main objective of this study was to obtain a specific frequency that allows a reduction in the viability and proliferation of glioblastoma (CT2A) and neuroblastoma (N2A) cell models. These were compared with an astrocyte cell model (C8D1A) (nontumor) to determine whether there is a specific frequency of response for each of the cell lines used. The CT2A, C8D1A, and N2A cell lines were exposed to a magnetic field of 100 µT and a variable frequency range between 20 and 100 Hz for 24, 48 and 72 h. The results fit a biological window model in which the viability and proliferation of N2A and CT2A cells decrease statistically significantly in a 50 Hz center of value window. In addition, the non-tumor cell model showed different behavior from tumor cell models depending on the applied frequency. These results are promising in the use of magnetic fields for therapeutic purposes.