The directional and long-range droplet transportation is of great importance in microfluidic systems. However, it usually requires external energy input. Here we designed a wettability gradient surface that can drive droplet motion by structural topography. The surface has a wettability gradient range of over 150° from superhydrophobic to hydrophilic, which was achieved by etching silicon nanopillars and adjusting the area of hydrophilic silicon dioxide plane. We conducted force analysis to further reveal the mechanism for droplet self-propulsion, and found that the nanostructures are critical to providing a large driving force and small resistance force. Theoretical calculation has been used to analyze the maximal self-propulsion displacement on different gradient surfaces with different volumes of droplets. On this basis, we designed several surfaces with arbitrary paths, which achieved directional and long-range transportation of droplet. These results clarify a driving mechanism for droplet self-propulsion on wettability gradient surfaces, and open up new opportunities for long-range and directional droplet transportation in microfluidic system.
Conventional spectrometer designs necessitate a compromise between their resolution and sensitivity, especially as device and detector dimensions are scaled down. Here, we report on a miniaturizable spectrometer platform where light throughput onto the detector is instead enhanced as the resolution is increased. This planar, CMOS-compatible platform is based around metasurface encoders designed to exhibit photonic bound states in the continuum, where operational range can be altered or extended simply through adjusting geometric parameters. This system can enhance photon collection efficiency by up to two orders of magnitude versus conventional designs; we demonstrate this sensitivity advantage through ultralow-intensity fluorescent and astrophotonic spectroscopy. This work represents a step forward for the practical utility of spectrometers, affording a route to integrated, chip-based devices that maintain high resolution and SNR without requiring prohibitively long integration times.
Flexible pressure sensors play a significant role in wearable devices and electronic skin. Iontronic pressure sensors with high sensitivity, wide measurement range, and high resolution can meet requirements. Based on the significant deformation characteristics of alveoli to improve compressibility, and the ability of the arch to disperse vertical pressure into horizontal thrust to increase contact area, a graded hollow ball arch (GHBA) microstructure is proposed, greatly improving sensitivity. The fabrication of GHBA ingeniously employs a double‐sided structure. One side uses mold casting to create convex structures, while the other utilizes the evaporation of moisture during the curing process to form concave structures. At the same time, a novel side‐by‐side package structure is proposed, ensuring pressure on flexible substrate is maximally transferred to the GHBA microstructure. Within the range of 0.2 Pa–300 kPa, the iontronic pressure sensor achieves a maximum sensitivity of 10 420.8 kPa−1, pressure resolution of 0.1% under the pressure of 100 kPa, and rapid response/recovery time of 40/35 ms. In wearable devices, it is capable of monitoring dumbbell curl exercises and wirelessly correcting sitting positions. In electronic skin, it can non‐contactly detect the location of the wind source and achieve object classification prediction when combined with the CNN model.
Triboelectric nanogenerators (TENGs) have excellent properties in harvesting tiny environmental energy and self-powered sensor systems with extensive application prospects. Here, we report a high sensitivity self-powered wind speed sensor based on triboelectric nanogenerators (TENGs). The sensor consists of the upper and lower two identical TENGs. The output electrical signal of each TENG can be used to detect wind speed so that we can make sure that the measurement is correct by two TENGs. We study the influence of different geometrical parameters on its sensitivity and then select a set of parameters with a relatively good output electrical signal. The sensitivity of the wind speed sensor with this set of parameters is 1.79 μA/(m/s) under a wind speed range from 15 m/s to 25 m/s. The sensor can light 50 LEDs at the wind speed of 15 m/s. This work not only advances the development of self-powered wind sensor systems but also promotes the application of wind speed sensing.
The emergence of microhemispherical resonant gyroscopes, which integrate the advantages of exceptional stability and long lifetime with miniaturization, has afforded new possibilities for the development of whole-angle gyroscopes. However, existing methods used for manufacturing microhemispherical resonant gyroscopes based on MEMS technology face the primary drawback of intricate and costly processing. Here, we report the design, fabrication, and characterization of the first 3D-printable microhemispherical shell resonator for a Coriolis vibrating gyroscope. We remarkably achieve fabrication in just two steps bypassing the dozen or so steps required in traditional micromachining. By utilizing the intricate shaping capability and ultrahigh precision offered by projection microstereolithography, we fabricate 3D high-aspect-ratio resonant structures and controllable capacitive air gaps, both of which are extremely difficult to obtain via MEMS technology. In addition, the resonance frequency of the fabricated resonators can be tuned by electrostatic forces, and the fabricated resonators exhibit a higher quality factor in air than do typical MEMS microhemispherical resonators. This work demonstrates the feasibility of rapidly batch-manufacturing microhemispherical shell resonators, paving the way for the development of microhemispherical resonator gyroscopes for portable inertial navigation. Moreover, this particular design concept could be further applied to increase uptake of resonator tools in the MEMS community.