Vincent Van den Bosch

Vincent Van den Bosch

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in JMIR Serious Games
Verified
Journal Article
Open access
MUMax Ulbrich
Max Ulbrich
VBVincent Van den Bosch
Vincent Van den Bosch
ABAndrea Bönsch
Andrea Bönsch
LGLennart Johannes Gruber
Lennart Johannes Gruber
MOMark Ooms
Mark Ooms
BPBehrus Puladi
Behrus Puladi
Background: As an integral part of computer-assisted surgery, virtual surgical planning (VSP) leads to significantly better surgery results, such as for oral and maxillofacial reconstruction with microvascular grafts of the fibula or iliac crest. It is performed on a 2D computer desktop screen (DS) based on preoperative medical imaging. However, in this environment, VSP is associated with shortcomings, such as a time-consuming planning process and the requirement of a learning process. Therefore, a virtual reality (VR)–based VSP application has great potential to reduce or even overcome these shortcomings due to the benefits of visuospatial vision, bimanual interaction, and full immersion. However, the efficacy of such a VR environment has not yet been investigated. Objective: This study aimed to demonstrate the possible advantages of a VR environment through a substep of VSP, specifically the segmentation of the fibula (calf bone) and os coxae (hip bone), by conducting a training course in both DS and VR environments and comparing the results. Methods: During the training course, 6 novices were taught how to use a software application in a DS environment (3D Slicer) and in a VR environment (Elucis) for the segmentation of the fibula and os coxae, and they were asked to carry out the maneuvers as accurately and quickly as possible. Overall, 13 fibula and 13 os coxae were segmented for each participant in both methods (VR and DS), resulting in 156 different models (78 fibula and 78 os coxae) per method (VR and DS) and 312 models in total. The individual learning processes in both environments were compared using objective criteria (time and segmentation performance) and self-reported questionnaires. The models resulting from the segmentation were compared mathematically (Hausdorff distance and Dice coefficient) and evaluated by 2 experienced radiologists in a blinded manner. Results: A much faster learning curve was observed for the VR environment than the DS environment (β=.86 vs β=.25). This nearly doubled the segmentation speed (cm3/min) by the end of training, leading to a shorter time (P<.001) to reach a qualitative result. However, there was no qualitative difference between the models for VR and DS (P=.99). The VR environment was perceived by participants as more intuitive and less exhausting, and was favored over the DS environment. Conclusions: The more rapid learning process and the ability to work faster in the VR environment could save time and reduce the VSP workload, providing certain advantages over the DS environment.

25 March 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SLSven Loosen
Sven Loosen
VBVincent Van den Bosch
Vincent Van den Bosch
JGJoão Gorgulho
João Gorgulho
MSMaximilian Schulze-Hagen
Maximilian Schulze-Hagen
JKJennis Kandler
Jennis Kandler
Christoph RoderburgChristoph Roderburg
Christoph Roderburg
Background: Immune checkpoint inhibitors (ICIs) represent a new therapeutic standard for an increasing number of tumor entities. Nevertheless, individual response and outcome to ICI is very heterogeneous, and the identification of the ideal ICI candidate has remained one of the major issues. Sarcopenia and the progressive loss of muscle mass and strength, as well as muscular fat deposition, have been established as negative prognostic factors for a variety of diseases, but their role in the context of ICI therapy is not fully understood. Here, we have evaluated skeletal muscle composition as a novel prognostic marker in patients undergoing ICI therapy for solid malignancies. Methods: We analyzed patients with metastasized cancers receiving ICI therapy according to the recommendation of the specific tumor board. Routine CT scans before treatment initialization and during ICI therapy were used to assess the skeletal muscle index (L3SMI) as well as the mean skeletal muscle attenuation (MMA) in n = 88 patients receiving ICI therapy. Results: While baseline L3SMI and MMA values were unsuitable for predicting the individual response and outcome to ICI therapy, longitudinal changes of the L3SMI and MMA (∆L3SMI, ∆MMA) during ICI therapy turned out to be a relevant marker of therapy response and overall survival. Patients who responded to ICI therapy at three months had a significantly higher ∆L3SMI compared to non-responders (−3.20 mm2/cm vs. 1.73 mm2/cm, p = 0.002). Moreover, overall survival (OS) was significantly lower in patients who had a strongly decreasing ∆L3SMI (<−6.18 mm2/cm) or a strongly decreasing ∆MMA (<−0.4 mm2/cm) during the first three month of ICI therapy. Median OS was only 127 days in patients with a ∆L3SMI of below −6.18 mm2/cm, compared to 547 days in patients with only mildly decreasing or even increasing ∆L3SMI values (p < 0.001). Conclusion: Both progressive sarcopenia and an increasing skeletal muscle fat deposition are associated with poor response and outcome to ICI therapy, which might help to guide treatment decisions during ICI therapy.

24 June 2022 in CardioVascular and Interventional Radiology
Verified
Journal Article
Open access
PDF file
VBVincent Van den Bosch
Vincent Van den Bosch
HSHizirwan Shukri Salim
Hizirwan Shukri Salim
NCNjin-Zu Chen
Njin-Zu Chen
OSOtto Stroosma
Otto Stroosma
PBPhilipp Bruners
Philipp Bruners
PIPeter Isfort
Peter Isfort
Purpose: To investigate the feasibility of a novel augmented reality system for CT-guided liver interventions and to compare it with free-hand interventions in a phantom setting. Methods and materials: A newly developed augmented reality interface was used, with projection of CT-imaging in multiplanar reconstruction and live rendering of the needle position, a bull`s eye view of the needle trajectory and a visualization of the distance to the target. Punctures were performed on a custom-made abdominal phantom by three interventional radiologists with different levels of expertise. Time and needle placement accuracy were measured. Two-tailed Wilcoxon signed rank test (p < 0.05) was performed to evaluate intraparticipant difference. Results: Intraparticipant puncture times were significantly shorter for each operator in the augmented reality condition (< 0.001 for the resident, < 0.001 for the junior staff member and 0.027 for the senior staff member). The junior staff member had an improvement in accuracy of 1 mm using augmented reality (p 0.026); the other two participants showed no significant improvement regarding accuracy. Conclusion: In this small series, it appears that the novel augmented reality system may improve the speed of CT-guided punctures in the phantom model compared to the free-hand procedure while maintaining a similar accuracy.

7 March 2024 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
CMClaire Melchior
Claire Melchior
PIPeter Isfort
Peter Isfort
TBTill Braunschweig
Till Braunschweig
Max Johannes Hendrikus WitjesMax Johannes Hendrikus Witjes
Max Johannes Hendrikus Witjes
VBVincent Van den Bosch
Vincent Van den Bosch
BPBehrus Puladi
Behrus Puladi
Objective: The gold standard of oral cancer (OC) treatment is diagnostic confirmation by biopsy followed by surgical treatment. However, studies have shown that dentists have difficulty performing biopsies, dental students lack knowledge about OC, and surgeons do not always maintain a safe margin during tumor resection. To address this, biopsies and resections could be trained under realistic conditions outside the patient. The aim of this study was to develop and to validate a porcine pseudotumor model of the tongue. Methods: An interdisciplinary team reflecting various specialties involved in the oncological treatment of head and neck oncology developed a porcine pseudotumor model of the tongue in which biopsies and resections can be practiced. The refined model was validated in a final trial of 10 participants who each resected four pseudotumors on a tongue, resulting in a total of 40 resected pseudotumors. The participants (7 residents and 3 specialists) had an experience in OC treatment ranging from 0.5 to 27 years. Resection margins (minimum and maximum) were assessed macroscopically and compared beside self-assessed margins and resection time between residents and specialists. Furthermore, the model was evaluated using Likert-type questions on haptic and radiological fidelity, its usefulness as a training model, as well as its imageability using CT and ultrasound. Results: The model haptically resembles OC (3.0 ± 0.5; 4-point Likert scale), can be visualized with medical imaging and macroscopically evaluated immediately after resection providing feedback. Although, participants (3.2 ± 0.4) tended to agree that they had resected the pseudotumor with an ideal safety margin (10 mm), the mean minimum resection margin was insufficient at 4.2 ± 1.2 mm (mean ± SD), comparable to reported margins in literature. Simultaneously, a maximum resection margin of 18.4 ± 6.1 mm was measured, indicating partial over-resection. Although specialists were faster at resection (p < 0.001), this had no effect on margins (p = 0.114). Overall, the model was well received by the participants, and they could see it being implemented in training (3.7 ± 0.5). Conclusion: The model, which is cost-effective, cryopreservable, and provides a risk-free training environment, is ideal for training in OC biopsy and resection and could be incorporated into dental, medical, or oncologic surgery curricula. Future studies should evaluate the long-term training effects using this model and its potential impact on improving patient outcomes.

13 December 2022 in CVIR Endovascular
Verified
Journal Article
Open access
PDF file
VBVincent Van den Bosch
Vincent Van den Bosch
FBFrédéric De Beukelaer
Frédéric De Beukelaer
PIPeter Isfort
Peter Isfort
SKSebastian Keil
Sebastian Keil
CKChristiane K. Kuhl
Christiane K. Kuhl
FPFederico Pedersoli
Federico Pedersoli
Background: Repositioning of dislocated port systems’ catheters is usually performed with a pigtail catheter and/or a goose snare. In case of an inaccessible port catheter tip due to thrombosis, this classic approach may be not successful. For these cases, we describe a long loop bailout technique with bifemoral access. Technique: Via a right transfemoral access, a first attempt to reposition the dislodged port catheter using pigtail catheter and goose snare was performed. After an unsuccessful attempt and delineation of thrombosis of the catheter tip, the contralateral femoral vein was subsequently punctured and a sheath was placed. Through both vascular sheaths, pigtail catheter and goose wire were advanced distally to the catheter. The guidewire in the pigtail catheter was snared, thus creating a “Long loop” configuration. Pulling down both catheters simultaneously with improved stability allowed to detach the catheter tip from the vessel wall and replacement into the superior vena cava was possible. Refinement of catheter tip position was done using the goose snare. This technique was applied on 5 patients with dislodged port catheters in the jugular vein (2/5), the innominate vein (1/5), the subclavian vein (1/5) and the azygos vein (1/5) with a technical success of 100%. No complications were observed. Conclusion: The Long loop technique can be used as salvage approach to reposition a dislodged catheter in case of failure with pigtail catheter and goose snare.

7 September 2022 in Research Square
Verified
Preprint
Open access
PDF file
VBVincent Van den Bosch
Vincent Van den Bosch
FBFrédéric De Beukelaer
Frédéric De Beukelaer
PIPeter Isfort
Peter Isfort
SKSebastian Keil
Sebastian Keil
CKChristiane K. Kuhl
Christiane K. Kuhl
FPFederico Pedersoli
Federico Pedersoli
Background Repositioning of dislocated port systems’ catheters is usually performed with a pigtail catheter and/or a goose snare. In case of an inaccessible port catheter tip due to thrombosis, this classic approach may be not successful. For these cases, we describe a long loop bailout technique with bifemoral access. Technique Via a right transfemoral access, a first attempt to reposition the dislodged port catheter using pigtail catheter and goose snare was performed. After an unsuccessful attempt and delineation of thrombosis of the catheter tip, the contralateral femoral vein was subsequently punctured and a sheath was placed. Through both vascular sheaths, pigtail catheter and goose wire were advanced distally to the catheter. The guidewire in the pigtail catheter was snared, thus creating a “Long loop” configuration. Pulling down both catheters simultaneously with improved stability allowed to detach the catheter tip from the vessel wall and replacement into the superior vena cava was possible. Refinement of catheter tip position was done using the goose snare . This technique was applied on 5 patients with dislodged port catheters in the jugular vein (2/5), the innominate vein (1/5), the subclavian vein (1/5) and the azygos vein (1/5) with a technical success of 100%. No complications were observed. Conclusion The Long loop technique can be used as salvage approach to reposition a dislodged catheter in case of failure with pigtail catheter and goose snare.