Zhiqiang Ai

Zhiqiang Ai


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2021 in Processes
Verified
Journal Article
Open access
PDF file
JYJiedong Ye
Jiedong Ye
JLJunshuai Lv
Junshuai Lv
Dongli TanDongli Tan
Dongli Tan
ZAZhiqiang Ai
Zhiqiang Ai
ZFZhiqiang Feng
Zhiqiang Feng
The NH3 uniformity and conversion rate produced by the urea–water solution spray system is an essential factor affecting de-NOx efficiency. In this work, a three-dimensional simulation model was developed with the CFD software and was employed to investigate the effects of two typical injection methods (wall injection and center injection) and three distribution strategies (pre-mixer, post-mixer, pre-mixer, and post-mixer) of two typical mixers on the urea conversion rate and uniformity. The field synergy principle was employed to analyze the heat transfer of different mixer flow fields. The results show that the single mixer has instability in optimizing different injection positions due to different injection methods and injection positions. The dual-mixer is stable in the optimization of the flow field under different conditions. The conclusion of the field synergy theory of the single mixer accords with the simulation result. The Fc of the dual-mixer cases is low, but the NH3 conversion and uniformity index rate are also improved due to the increase in the residence time of UWS.

3 August 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
XHXiaochun Han
Xiaochun Han
XWXuan Wang
Xuan Wang
RLRunze Liu
Runze Liu
JYJunjie Yin
Junjie Yin
ZAZhiqiang Ai
Zhiqiang Ai
LHLI HUI HAO
LI HUI HAO
In this study, an electrochemical immunosensor based on polyaniline/nano-Fe3O4 (PANI/Nano-Fe3O4) nanocomposite (PANI/Nano-Fe3O4/Anti-FLA/BSA/GCE) was developed for the highly sensitive and selective detection of trace levels of fluoranthene (FLA) in marine environments. Fluoranthene antibodies (Anti-FLA) were covalently immobilized on a glassy carbon electrode (GCE) modified with PANI/Nano-Fe3O4 via an EDC/NHS activation strategy, enabling specific recognition of FLA based on the antigen–antibody binding mechanism. The performance of the sensor was systematically optimized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), linear sweep voltammetry (LSV), and differential pulse voltammetry (DPV). The results demonstrated a linear inverse relationship between peak current (Ip) and FLA concentration in the range of 0.5~80 ng/mL, with a regression equation of I = −1.55C + 174.602 (R2 = 0.996). The limit of detection (LOD) was as low as 0.354 ng/mL (S/N = 3). In real seawater sample analysis, spiked recovery tests at three representative sites in the Maowei Sea, Guangxi, yielded recoveries of 95.44%~97.51%, with RSDs below 3%, confirming the sensor’s resistance to matrix interference. The synergistic effect of the porous conductive network of PANI and the high specific surface area of Nano-Fe3O4 significantly amplified the electrochemical signal, while the molecular specificity of the antibody ensured targeted recognition. This sensor provides a novel and effective approach for the on-site rapid detection of polycyclic aromatic hydrocarbon (PAH) pollutants in complex marine environments, offering both high sensitivity and selectivity.