Christopher Kittel

Dr. Christopher Kittel


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2021 in Cancers
Verified
Journal Article
Open access
PDF file
MOMichael Oertel
Michael Oertel
CKChristopher Kittel
Christopher Kittel
JMJonas Martel
Jonas Martel
JMJan-Henrik Mikesch
Jan-Henrik Mikesch
MGMarco Glashoerster
Marco Glashoerster
Hans Theodor EichHans Theodor Eich
Hans Theodor Eich
Total body irradiation (TBI) is an essential part of various conditioning regimens prior to allogeneic stem cell transplantation, but is accompanied by relevant (long-term) toxicities. In the lungs, a complex mechanism induces initial inflammation (pneumonitis) followed by chronic fibrosis. The hereby presented analysis investigates the occurrence of pulmonary toxicity in a large patient collective and correlates it with data derived from normal tissue complication probability (NTCP) calculations. The clinical data of 335 hemato-oncological patients undergoing TBI were analyzed with a follow-up of 85 months. Overall, 24.8% of all patients displayed lung toxicities, predominantly pneumonia and pulmonary obstructions (13.4% and 6.0%, respectively). NTCP calculations estimated median risks to be 20.3%, 0.6% and 20.4% for overall pneumonitis (both radiological and clinical), symptomatic pneumonitis and lung fibrosis, respectively. These numbers are consistent with real-world data from the literature and further specify radiological and clinical apparent toxicity rates. Overall, the estimated risk for clinical apparent pneumonitis is very low, corresponding to the probability of non-infectious acute respiratory distress syndrome, although the underlying pathophysiology is not identical. Radiological pneumonitis and lung fibrosis are expected to be more common but require a more precise documentation by the transplantation team, radiologists and radiation oncologists.

9 August 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SSSergiu Scobioala
Sergiu Scobioala
CKChristopher Kittel
Christopher Kittel
Khaled ElsayadKhaled Elsayad
Khaled Elsayad
KKKai Kroeger
Kai Kroeger
MOMichael Oertel
Michael Oertel
Hans Theodor EichHans Theodor Eich
Hans Theodor Eich
Comparing radiation treatment plans by using the same safety margins and dose objectives for all techniques, to ascertain the optimal radiation technique for the stereotactic body radiotherapy (SBRT) of low-risk prostate cancer. Treatment plans for 27 randomly selected patients were compared using intensity-modulated (IMRT) techniques as Sliding Window (SW), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT), as well as Cyber Knife (CK) system. The target dose was calculated to 36.25 Gy delivered in five fractions over 1 week. Dosimetric indices for target volume and organs at risk (OAR) as well as normal tissue complication probability (NTCP) of late rectal and urinary bladder toxicities were analyzed. The CK provided lower homogeneity in the target volume, but higher values for most of the conformity indices compared to the IMRT approaches. The SW demonstrated superior rectum sparing at medium-to-high dose range (V18 Gy - V32.6 Gy) compared to other techniques (p < 0.05). The whole urinary bladder experienced the best shielding by SW and VMAT at the medium dose (V18 Gy, p < 0.05 versus CK), however we obtained no relevant differences between techniques at the high dose. Generally, the CK demonstrated significantly superior rectum and bladder exposure at V18 Gy as compared to HT, SW, and VMAT. For the rectum, mean NTCP values were significantly superior for HT (NTCP = 2.3%, p < 0.05), and for urinary bladder, the NTCP showed no significant advantages for any technique. No absolute dosimetric advantage was revealed to choose between CK or IMRT techniques for the SBRT of low-grade prostate cancer. Using the same safety margins and dose objectives, IMRT techniques demonstrated superior sparing of the rectum and bladder at a medium dose compared to CK. Comparing different IMRT approaches SW displayed superior rectum sparing at a medium-to-high dose range, whereas both SW and RA revealed superior bladder sparing compared to HT. HT demonstrated a significantly lower NTCP outcome compared to CK or IMRT techniques regarding the rectum. Radiation plans can be optimized further by an individual modification of dose objectives independent of the treatment plan strategy.

27 September 2016 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SSSergiu Scobioala
Sergiu Scobioala
CKChristopher Kittel
Christopher Kittel
NWNicolas Wissmann
Nicolas Wissmann
UHUwe Haverkamp
Uwe Haverkamp
MCMohammed Channaoui
Mohammed Channaoui
Hans Theodor EichHans Theodor Eich
Hans Theodor Eich
Comparing radiation treatment plans to ascertain the optimal intensity-modulated radiation technique for low-risk prostate cancer. Treatment plans for 20 randomly selected patients were generated using the same dose objectives. A dosimetric comparison was performed between various intensity-modulated techniques, including protons. All treatment plans provided conventional treatment with 79.2Gy. Dosimetric indices for the target volume and organs at risk (OAR), including homogeneity index and four conformity indices were analyzed. No statistically significant differences between techniques were observed for homogeneity values. Dose distributions showed significant differences at low-to-medium doses. At doses above 50Gy all techniques revealed a steep dose gradient outside the planning target volume (PTV). Protons demonstrated superior rectum sparing at low-to-higher doses (V10-V70, P < .05) and bladder sparing at low-to-medium doses (V10–V30, P < .05). Helical tomotherapy (HT) provided superior rectum sparing compared to Sliding Window (SW) and Rapid Arc (RA) (V10–V70, P < .05). SW displayed superior bladder sparing compared to HT and RA (V10–V50, P < .05). Protons generated significantly higher femoral heads exposure and HT had superior sparing of those. All techniques are able to provide a homogeneous and highly conformal dose distribution. Protons demonstrated superior sparing of the rectum and bladder at a wide dose spectrum. The radiation technique itself as well as treatment planning algorithms result in different OAR sparing between HT, SW and RA, with superior rectum sparing by HT and superior bladder sparing by SW. Radiation plans can be further optimized by individual modification of dose objectives dependent on treatment plan strategy.

26 August 2021 in Cancers
Verified
Journal Article
Open access
PDF file
LSLaith Samhouri
Laith Samhouri
MMMohamed Meheissen
Mohamed Meheissen
AIAhmad Khalil Ibrahimi
Ahmad Khalil Ibrahimi
AAAbdellatif Almousa
Abdellatif Almousa
MZMomen Zeineddin
Momen Zeineddin
Hans Theodor EichHans Theodor Eich
Hans Theodor Eich
Background: Central neurocytoma (CN) is a rare tumor accounting for <0.5% of all intracranial tumors. Surgery ± radiotherapy is the mainstay treatment. This international multicentric study aims to evaluate the outcomes of CNs patients after multimodal therapies and identify predictive factors. Patients and methods: We retrospectively identified 33 patients with CN treated between 2005 and 2019. Treatment characteristics and outcomes were assessed. Results: All patients with CN underwent surgical resection. Radiotherapy was delivered in 19 patients. The median radiation dose was 54 Gy (range, 50–60 Gy). The median follow-up time was 56 months. The 5-year OS and 5-year PFS were 90% and 76%, respectively. Patients who received radiotherapy had a significantly longer PFS than patients without RT (p = 0.004) and a trend towards longer OS. In addition, complete response after treatments was associated with longer PFS (p = 0.07). Conclusions: Using RT seems to be associated with longer survival rates with an acceptable toxicity profile.

31 May 2018 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
SSSergiu Scobioala
Sergiu Scobioala
CKChristopher Kittel
Christopher Kittel
PNPhilipp Niermann
Philipp Niermann
HWHeidi Wolters
Heidi Wolters
KSKatharina Helene Susek
Katharina Helene Susek
HEHans Theodor Eich
Hans Theodor Eich

19 March 2021 in Cancers
Verified
Journal Article
Open access
PDF file
Gabriele ReinartzGabriele Reinartz
Gabriele Reinartz
ABAndrea Baehr
Andrea Baehr
CKChristopher Kittel
Christopher Kittel
MOMichael Oertel
Michael Oertel
UHUwe Haverkamp
Uwe Haverkamp
Hans Theodor EichHans Theodor Eich
Hans Theodor Eich
Successful studies on radiation therapy for gastric lymphoma led to a decrease in planning target volume (PTV) and radiation dose with low toxicities, maintaining excellent survival rates. It remains unclear as to which effects are to be expected concerning dose burden on organs at risk (OAR) by decrease in PTV vs. dose and whether a direct impact on toxicity might be expected. We evaluated 72 radiation plans, generated prospectively for a cohort of 18 patients who were treated for indolent gastric lymphoma in our department. As a prospective work, four radiation plans with different radiation doses and target volumes (40 Gy-involved field, 40 Gy-involved site, 30 Gy-involved field, 30 Gy-involved site) were generated for each patient. Mean dose burden on adjacent organs was compared between the planning groups. Cohort toxicity data served to estimate parameters for the Lyman–Kutcher–Burman (LKB) model for normal tissue complication probability (NTCP). These were used to anticipate adverse events for OAR. Literature parameters were used to estimate high-grade toxicities of OAR. Decrease of dose and/or PTV led to median dose reductions between 0.13 and 5.2 Gy, with a significant dose reduction on neighboring organs. Estimated model parameters for liver, spleen, and bowel toxicity were feasible to predict cohort toxicities. NTCP for the endpoints elevated liver enzymes, low platelet count, and diarrhea ranged between 15.9 and 22.8%, 27.6 and 32.4%, and 21.8 and 26.4% for the respective four plan variations. Field and dose reduction highly impact dose burden and NTCP for OAR during stomach radiation. Our estimated LKB model parameters offer a good approximation for low-grade toxicities in abdominal organs with modern radiation techniques.