Bart Dierickx

Bart Dierickx

orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2000 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
SKS. Kavadias
S. Kavadias
BDBart Dierickx
Bart Dierickx
DSD. Scheffer
D. Scheffer
AAA. Alaerts
A. Alaerts
DUD. Uwaerts
D. Uwaerts
JBJ. Bogaerts
J. Bogaerts
CMOS image sensors with logarithmic response are attractive devices for applications where a high dynamic range is required. Their strong point is the high dynamic range. Their weak point is the sensitivity to pixel parameter variations introduced during fabrication. This gives rise to a considerable fixed pattern noise (FPN) that deteriorates the image quality unless pixel calibration is used. In the present work a technique to remove the FPN by employing on-chip calibration is introduced, where the effect of threshold voltage variations in pixels is cancelled. An image sensor based on an active pixel structure with five transistors has been designed, fabricated, and tested. The sensor consists of 525/spl times/525 pixels measuring 7.5 /spl mu/m/spl times/10 /spl mu/m, and is fabricated in a 0.5-/spl mu/m CMOS process. The measured dynamic range is 120 dB while the FPN is 2.5% of the output signal range.

24 February 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
KSKunal Sahasrabuddhe
Kunal Sahasrabuddhe
AKAamir A Khan
Aamir A Khan
ASAditya Pratap Singh
Aditya Pratap Singh
TSTyler Michael Stern
Tyler Michael Stern
YNYeena Ng
Yeena Ng
MAMatthew R Angle
Matthew R Angle
Objective. Decoding neural activity has been limited by the lack of tools available to record from large numbers of neurons across multiple cortical regions simultaneously with high temporal fidelity. To this end, we developed the Argo system to record cortical neural activity at high data rates. Approach. Here we demonstrate a massively parallel neural recording system based on platinum-iridium microwire electrode arrays bonded to a CMOS voltage amplifier array. The Argo system is the highest channel count in vivo neural recording system, supporting simultaneous recording from 65 536 channels, sampled at 32 kHz and 12-bit resolution. This system was designed for cortical recordings, compatible with both penetrating and surface microelectrodes. Main results. We validated this system through initial bench testing to determine specific gain and noise characteristics of bonded microwires, followed by in-vivo experiments in both rat and sheep cortex. We recorded spiking activity from 791 neurons in rats and surface local field potential activity from over 30 000 channels in sheep. Significance. These are the largest channel count microwire-based recordings in both rat and sheep. While currently adapted for head-fixed recording, the microwire-CMOS architecture is well suited for clinical translation. Thus, this demonstration helps pave the way for a future high data rate intracortical implant.

1 January 1992 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
ESE. Simoen
E. Simoen
BDBart Dierickx
Bart Dierickx
CCC.L. Claeys
C.L. Claeys
GDG.J. Declerck
G.J. Declerck

10 March 2003 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
JBJ. Bogaerts
J. Bogaerts
BDBart Dierickx
Bart Dierickx
GMG. Meynants
G. Meynants
DUD. Uwaerts
D. Uwaerts
A 512/spl times/512 CMOS active pixel sensor (APS) was designed and fabricated in a standard 0.5-/spl mu/m technology. The radiation tolerance of the sensor has been evaluated with Co-60 and proton irradiation with proton energies ranging from 11.7 to 59 MeV. The most pronounced radiation effect is the increase of the dark current. However, the total ionizing dose-induced dark current increase is orders of magnitude smaller than in standard devices. It behaves logarithmically with dose and anneals at room temperature. The dark current increase due to proton displacement damage is explained in terms of the nonionizing energy loss of the protons. The fixed pattern noise does not increase with total ionizing dose. Responsivity changes are observed after Co-60 and proton irradiation, but a definitive cause has not yet been established.

1 January 1997 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
DSD. Scheffer
D. Scheffer
BDBart Dierickx
Bart Dierickx
GMG. Meynants
G. Meynants

1 July 1988 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
BDBart Dierickx
Bart Dierickx
LWL. Warmerdam
L. Warmerdam
ESE.R. Simoen
E.R. Simoen
JVJ. Vermeiren
J. Vermeiren
CCC. Claeys
C. Claeys