Optical coherence tomography (OCT) is a noninvasive diagnostic method that offers a view into the superficial layers of the skin in vivo in real-time. An infrared broadband light source allows the investigation of skin architecture and changes up to a depth of 1 to 2 mm with a resolution between 15 and 3 μm, depending on the system used. Thus OCT enables evaluation of skin lesions, especially nonmelanoma skin cancers and inflammatory diseases, quantification of skin changes, visualization of parasitic infestations, and examination of other indications such as the investigation of nails. OCT provides a quick and useful diagnostic imaging technique for a number of clinical questions and is a valuable addition or complement to other noninvasive imaging tools such as dermoscopy, high-frequency ultrasound, and confocal laser scan microscopy.
Optical coherence tomography (OCT) represents a non-invasive imaging technology, which may be applied to the diagnosis of non-melanoma skin cancer and which has recently been shown to improve the diagnostic accuracy of basal cell carcinoma. Technical developments of OCT continue to expand the applicability of OCT for different neoplastic and inflammatory skin diseases. Of these, dynamic OCT (D-OCT) based on speckle variance OCT is of special interest as it allows the in vivo evaluation of blood vessels and their distribution within specific lesions, providing additional functional information and consequently greater density of data. In an effort to assess the potential of D-OCT for future scientific and clinical studies, we have therefore reviewed the literature and preliminary unpublished data on the visualization of the microvasculature using D-OCT. Information on D-OCT in skin cancers including melanoma, as well as in a variety of other skin diseases, is presented in an atlas. Possible diagnostic features are suggested, although these require additional validation.
Background Even though progress has been made, the detection of melanoma still poses a challenge. In light of this situation, the Nevisense electrical impedance spectroscopy (EIS) system (SciBase AB, Stockholm, Sweden) was designed and shown to have the potential to be used as an adjunct diagnostic tool for melanoma detection. Objectives To assess the effectiveness and safety of the Nevisense system in the distinction of benign lesions of the skin from melanoma with electrical impedance spectroscopy. Methods This multicentre, prospective, and blinded clinical study was conducted at five American and 17 European investigational sites. All eligible skin lesions in the study were examined with the EIS‐based Nevisense system, photographed, removed by excisional biopsy and subjected to histopathological evaluation. A postprocedure clinical follow‐up was conducted at 7 ± 3 days from the initial measurement. A total of 1951 patients with 2416 lesions were enrolled into the study; 1943 lesions were eligible and evaluable for the primary efficacy end point, including 265 melanomas – 112 in situ and 153 invasive melanomas with a median Breslow thickness of 0·57 mm [48 basal cell carcinomas (BCCs) and seven squamous cell carcinomas (SCCs)]. Results The observed sensitivity of Nevisense was 96·6% (256 of 265 melanomas) with an exact one‐sided 95% lower confidence bound estimated at 94·2% and an observed specificity of 34·4%, and an exact two‐sided 95% confidence bound estimated at 32·0–36·9%. The positive and negative predictive values of Nevisense were 21·1% and 98·2%, respectively. The observed sensitivity for nonmelanoma skin cancer was 100% (55 of 48 BCCs and seven SCCs) with an exact two‐sided 95% confidence bound estimated at 93·5–100·0%. Conclusions Nevisense is an accurate and safe device to support clinicians in the detection of cutaneous melanoma.
Background The diagnostic criteria for basal cell carcinoma (BCC) using optical coherence tomography (OCT) have been described previously, but the clinical value of these findings remains unknown. Objectives To investigate the diagnostic value of OCT for BCC in a typical clinical setting. The primary efficacy end point was a diagnosis of BCC for each lesion. Secondary end points were the diagnosis of other possible conditions. Methods This was an observational, prospective, multicentre study in which consecutive patients with nonpigmented pink lesions suspicious for BCC underwent clinical assessment, dermoscopy and OCT, with the diagnosis recorded at each stage. Once all diagnoses had been recorded, the histological results were disclosed. In total 164 patients with 256 lesions were recruited. Histology was missing for 21 lesions, leaving 235 lesions in 155 patients for analysis. Results Sixty per cent of lesions (141 of 235) were identified as BCC by histology. A slight increase of sensitivity was noted following OCT, which did not reach statistical significance. The specificity increased significantly from 28·6% by clinical assessment to 54·3% using dermoscopy and to 75·3% with the addition of OCT (P < 0·001). The positive predictive value for the diagnosis of BCC using OCT was 85·2% [95% confidence interval (CI) 78·6–90·4], and the negative predictive value was 92·1% (95% CI 83·6–97·0). The accuracy of diagnosis for all lesions increased from 65·8% with clinical evaluation to 76·2% following additional dermoscopy and to 87·4% with the addition of OCT. Conclusions OCT significantly improved the diagnostic specificity for BCC compared with clinical assessment and dermoscopy alone.
About Me
Noninvasive Imaging of skin tumors, early diagnosis, treatment monitoring
Noninvasive Imaging of skin tumors, early diagnosis, treatment monitoring