Giovanni Bortolan

Dr. Giovanni Bortolan

orcid

Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 1985 in Fuzzy Sets and Systems
Verified
Journal Article
Closed access
GBGiovanni Bortolan
Giovanni Bortolan
RDR. Degani
R. Degani

1 April 1988 in International Journal of Approximate Reasoning
Verified
Journal Article
Closed access
RDRosanna Degani
Rosanna Degani
GBGiovanni Bortolan
Giovanni Bortolan

20 January 2005 in Physiological Measurement
Verified
Journal Article
Closed access
ICI Christov
I Christov
IJI Jekova
I Jekova
GBGiovanni Bortolan
Giovanni Bortolan
An analysis of electrocardiographic pattern recognition parameters for premature ventricular contraction (PVC) and normal (N) beat classification is presented. Twenty-six parameters were defined: 11 x 2 for the two electrocardiogram (ECG) leads, width of the complex and three parameters derived from a single-plane vectorcardiogram (VCG). Some of the parameters include amplitudes of maximal positive and maximal negative peaks, area of absolute values, area of positive values, area of negative values, number of samples with 70% higher amplitude than that of the highest peak, amplitude and angle of the QRS vector in a VCG plane. They were measured for all heartbeats annotated as N or PVC in all 48 ECG recordings of the MIT-BIH arrhythmia database. Two reference sets for the Kth nearest-neighbours rule were used-global and local. The classification indices obtained with the global reference set were 75.4% specificity and 80.9% sensitivity. Using the local reference set we increased the specificity to 96.7% and the sensitivity to 96.9%. The achieved specificity and sensitivity are comparable with, and greater than, the results reported in the literature.

1 March 2007 in Medical Engineering & Physics
Verified
Journal Article
Closed access
IJIrena Jekova
Irena Jekova
GBGiovanni Bortolan
Giovanni Bortolan
ICI. Christov
I. Christov
The most common way to diagnose cardiac dysfunctions is the ECG signal analysis, usually starting with the assessment of the QRS complex as the most significant wave in the electrocardiogram. Many methods for automatic heartbeats classification have been applied and reported in the literature but the use of different ECG features and the training and testing on different datasets, makes their direct comparison questionable. This paper presents a comparative study of the learning capacity and the classification abilities of four classification methods--Kth nearest neighbour rule, neural networks, discriminant analysis and fuzzy logic. They were applied on 26 morphological parameters, which include information of amplitude, area, interval durations and the QRS vector in a VCG plane and were tested for five types of ventricular complexes--normal heart beats, premature ventricular contractions, left and right bundled branch blocks, and paced beats. One global, one basic and two local learning sets were used. A small-sized learning set, containing the five types of QRS complexes collected from all patients in the MIT-BIH database, was used either with or without applying the leave one out rule, thus representing the global and the basic learning set, respectively. The local learning sets consisted of heartbeats only from the tested patient, which were taken either consecutively or randomly. Using the local learning sets the assessed methods achieved high accuracies, while the small size of the basic learning set was balanced by reduced classification ability. Expectedly, the worst results were obtained with the global learning set.

12 August 2004 in Physiological Measurement
Verified
Journal Article
Closed access
ICI Christov
I Christov
GBGiovanni Bortolan
Giovanni Bortolan
Detection and classification of ventricular complexes from a limited number of ECG leads is of considerable importance in critical care or operating room patient monitoring. Beat-to-beat detection allows the heart rhythm evolution to be followed and various types of arrhythmia to be recognized. A quantitative analysis is proposed of pattern recognition parameters for classification of normal QRS complexes and premature ventricular contractions (PVC). Twenty-six parameters have been defined: the width of the QRS complex, three vectorcardiogram parameters and 11 from two ECG leads. These parameters include: amplitudes of positive and negative peaks, area of positive and negative waves, various time-interval durations, amplitude and angle of the QRS vector, etc. They are measured for all QRS complexes annotated as 'normals' and 'PVCs' from the 48 ECG recordings of the MIT-BIH arrhythmia database. Neural networks (NN) are shown to be a useful instrument for the analysis of large quantities of parameters. Separate ranking of any parameter and homogeneous group ranking (amplitude, area, interval, slope and vector) were performed. From the two ECG leads, the first three ranked parameter groups for clustering of PVCs are amplitude, slope and interval, while for N clustering they are vector, amplitude and area. Considering the entire parameter set, we obtained N = 99.7% correct detection of normal QRS complexes and PVC = 98.5% of premature ventricular complexes. The study also shows that simultaneous analysis of two ECG channels yields better accuracy compared to using a single channel: the improvement is 0.1% in the classification of N beats and 4.5% for PVC beats.

1 January 1996 in Journal of Electrocardiology
Verified
Journal Article
Closed access
GBGiovanni Bortolan
Giovanni Bortolan
CBChristian Brohet
Christian Brohet
SFSergio Fusaro
Sergio Fusaro