Lei Sun

Prof. Dr. Lei Sun

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in iScience
Verified
Journal Article
Open access
ZQZhihai Qiu
Zhihai Qiu
JGJinghui Guo
Jinghui Guo
SKShashwati Kala
Shashwati Kala
JZJiejun Zhu
Jiejun Zhu
QXQuanxiang Xian
Quanxiang Xian
LSLei Sun
Lei Sun
Ultrasound brain stimulation is a promising modality for probing brain function and treating brain disease non-invasively and with high spatiotemporal resolution. However, the mechanism underlying its effects remains unclear. Here, we examine the role that the mouse piezo-type mechanosensitive ion channel component 1 (Piezo1) plays in mediating the in vitro effects of ultrasound in mouse primary cortical neurons and a neuronal cell line. We show that ultrasound alone could activate heterologous and endogenous Piezo1, initiating calcium influx and increased nuclear c-Fos expression in primary neurons but not when pre-treated with a Piezo1 inhibitor. We also found that ultrasound significantly increased the expression of the important proteins phospho-CaMKII, phospho-CREB, and c-Fos in a neuronal cell line, but Piezo1 knockdown significantly reduced this effect. Our findings demonstrate that the activity of mechanosensitive ion channels such as Piezo1 stimulated by ultrasound is an important contributor to its ability to stimulate cells in vitro.

25 April 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
JZJiejun Zhu
Jiejun Zhu
QXQuanxiang Xian
Quanxiang Xian
XHXuandi Hou
Xuandi Hou
KWKin Fung Wong
Kin Fung Wong
TZTingting Zhu
Tingting Zhu
LSLei Sun
Lei Sun
Transcranial low-intensity ultrasound is a promising neuromodulation modality, with the advantages of noninvasiveness, deep penetration, and high spatiotemporal accuracy. However, the underlying biological mechanism of ultrasonic neuromodulation remains unclear, hindering the development of efficacious treatments. Here, the well-known Piezo1 was studied through a conditional knockout mouse model as a major mediator for ultrasound neuromodulation ex vivo and in vivo. We showed that Piezo1 knockout (P1KO) in the right motor cortex of mice significantly reduced ultrasound-induced neuronal calcium responses, limb movement, and muscle electromyogram (EMG) responses. We also detected higher Piezo1 expression in the central amygdala (CEA), which was found to be more sensitive to ultrasound stimulation than the cortex was. Knocking out the Piezo1 in CEA neurons showed a significant reduction of response under ultrasound stimulation, while knocking out astrocytic Piezo1 showed no-obvious changes in neuronal responses. Additionally, we excluded an auditory confound by monitoring auditory cortical activation and using smooth waveform ultrasound with randomized parameters to stimulate P1KO ipsilateral and contralateral regions of the same brain and recording evoked movement in the corresponding limb. Thus, we demonstrate that Piezo1 is functionally expressed in different brain regions and that it is an important mediator of ultrasound neuromodulation in the brain, laying the ground for further mechanistic studies of ultrasound.

26 March 2007 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Qifa ZhouQifa Zhou
Qifa Zhou
XXXiaochen Xu
Xiaochen Xu
EGEmanuel J. Gottlieb
Emanuel J. Gottlieb
LSLei Sun
Lei Sun
JCJonathan M. Cannata
Jonathan M. Cannata
KSK. Kirk Shung
K. Kirk Shung
High-frequency needle ultrasound transducers with an aperture size of 0.4 mm were fabricated using lead magnesium niobate-lead titanate (PMN-33%PT) as the active piezoelectric material. The active element was bonded to a conductive silver particle matching layer and a conductive epoxy backing through direct contact curing. An outer matching layer of parylene was formed by vapor deposition. The active element was housed within a polyimide tube and a 20-gauge needle housing. The magnitude and phase of the electrical impedance of the transducer were 47 Omega and -38deg, respectively. The measured center frequency and -6 dB fractional bandwidth of the PMN-PT needle transducer were 44 MHz and 45%, respectively. The two-way insertion loss was approximately 15 dB. In vivo high-frequency, pulsed-wave Doppler patterns of blood flow in the posterior portion and in vitro ultrasonic backscatter microscope (UBM) images of the rabbit eye were obtained with the 44-MHz needle transducer

1 August 2020 in Cell Reports
Verified
Journal Article
Open access
ZQZhihai Qiu
Zhihai Qiu
SKShashwati Kala
Shashwati Kala
JGJinghui Guo
Jinghui Guo
QXQuanxiang Xian
Quanxiang Xian
JZJiejun Zhu
Jiejun Zhu
LSLei Sun
Lei Sun
Recently developed brain stimulation techniques have significantly advanced our ability to manipulate the brain's function. However, stimulating specific neurons in a desired region without significant surgical invasion remains a challenge. Here, we demonstrate a neuron-specific and region-targeted neural excitation strategy using non-invasive ultrasound through activation of heterologously expressed mechanosensitive ion channels (MscL-G22S). Low-intensity ultrasound is significantly better at inducing Ca2+ influx and neuron activation in vitro and at evoking electromyogram (EMG) responses in vivo in targeted cells expressing MscL-G22S. Neurons in the cerebral cortex or dorsomedial striatum of mice are made to express MscL-G22S and stimulated ultrasonically. We find significant upregulation of c-Fos in neuron nuclei only in the regions expressing MscL-G22S compared with the non-MscL controls, as well as in various other regions in the same brain. Thus, we detail an effective approach for activating specific regions and cell types in intact mouse brains by sensitizing them to ultrasound using a mechanosensitive ion channel.

1 May 2020 in Acta Biomaterialia
Verified
Journal Article
Open access
LSLin Song
Lin Song
GWGuohao Wang
Guohao Wang
XHXuandi Hou
Xuandi Hou
SKShashwati Kala
Shashwati Kala
ZQZhihai Qiu
Zhihai Qiu
LSLei Sun
Lei Sun
Tumor hypoxia is believed to be a factor limiting successful outcomes of oxygen-consuming cancer therapy, thereby reducing patient survival. A key strategy to overcome tumor hypoxia is to increase the prevalence of oxygen at the tumor site. Oxygen-containing microbubbles/nanobubbles have been developed to supply oxygen and enhance the effects of therapies such as radiotherapy and photodynamic therapy. However, the application of these bubbles is constrained by their poor stability, requiring major workarounds to increase their half-lives. In this study, we explore the potential of biogenic gas vesicles (GVs) as a new kind of oxygen carrier to alleviate tumor hypoxia. GVs, which are naturally formed, gas-filled, protein-shelled compartments, were modified on the surface of their protein shells by a layer of liposome. A substantial improvement of oxygen concentration was observed in hypoxic solution, in hypoxic cells, as well as in subcutaneous tumors when lipid-GVs(O2) were added/tail-injected. Significant enhancement of tumor cell apoptosis and necrosis was also observed during photodynamic therapy (PDT) in the presence of lipid-GVs(O2) both in vitro and in vivo. Lipid-GVs(O2) alone induced no obvious change in cell viability in vitro or any apparent pathological abnormalities after mice were tail-injected with them. In all, lipid-GVs exhibited promising performance for intravenous gas delivery, enhanced PDT efficacy and low toxicity, a quality that may be applied to alleviate hypoxia in cancers, as well as hypoxia-related clinical treatments. STATEMENT OF SIGNIFICANCE: The development of stable oxygen-filled micro/nanobubbles capable of delivering oxygen to tumor sites is a major hurdle to enhancing the efficacy of cancer therapy. Currently, micro/nanobubbles are limited by their instability when oxygen is encapsulated, creating a large pressure gradient and surface tension. To improve stability, we modified the surfaces of GVs, a biogenic stable nanoscale hollow structure, as a new class of oxygen carriers. Lipid-coated GVs were found to be stable in solution and effective O2 carriers. This will overcome the limitations of coalescence, short circulation time of synthetic bubbles during application. Our surface-modified GVs demonstrated low toxicity in vitro cell in vivo, while also being able to overcome hypoxia-associated therapy resistance when combined with photodynamic therapy.

1 January 2008 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
LSLei Sun
Lei Sun
CLChing-Ling Lien
Ching-Ling Lien
XXXiaochen Xu
Xiaochen Xu
KSK. Kirk Shung
K. Kirk Shung