Winfried Amoaku

Dr. Winfried Amoaku

Division of Ophthalmology and Visual Sciences, B Floor, Eye and ENT Building, Queen’s Medical Centre, University of Nottingham, Nottingham NG7 2UH, UK

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2015 in Eye
Verified
Journal Article
Closed access
PDF file
Winfried AmoakuWinfried Amoaku
Winfried Amoaku
UCU Chakravarthy
U Chakravarthy
RGR Gale
R Gale
MGM Gavin
M Gavin
FGF Ghanchi
F Ghanchi
YYY Yang
Y Yang

1 June 2020 in Eye
Verified
Journal Article
Closed access
PDF file
Winfried AmoakuWinfried Amoaku
Winfried Amoaku
FGFaruque Ghanchi
Faruque Ghanchi
CBClare Bailey
Clare Bailey
SBSanjiv Banerjee
Sanjiv Banerjee
SBSomnath Banerjee
Somnath Banerjee
HMHemal Mehta
Hemal Mehta

7 May 2004 in Eye
Verified
Journal Article
Closed access
CNC T Ntim-Amponsah
C T Ntim-Amponsah
Winfried AmoakuWinfried Amoaku
Winfried Amoaku
SOS Ofosu-Amaah
S Ofosu-Amaah
RER K Ewusi
R K Ewusi
RIR Idirisuriya-Khair
R Idirisuriya-Khair
MAM Adu-Darko
M Adu-Darko

17 March 2022 in Eye
Verified
Journal Article
Closed access
PDF file
LNLuke Nicholson
Luke Nicholson
STStephen J. Talks
Stephen J. Talks
Winfried AmoakuWinfried Amoaku
Winfried Amoaku
KTKatherine Talks
Katherine Talks
SSSobha Sivaprasad
Sobha Sivaprasad

1 May 2006 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
HSH Shahid
H Shahid
PHP Hossain
P Hossain
Winfried AmoakuWinfried Amoaku
Winfried Amoaku
Retinal vein occlusions (RVO) are the second commonest sight threatening vascular disorder. Despite its frequency treatments for RVO are unsatisfactory and include several that have not been tested by large, well designed, prospective, randomised controlled trials. There is also the lack of long term follow up in many of the available small uncontrolled studies, and the timings of interventions are haphazard. This review aims to evaluate the current knowledge relating to the pathogenesis, suggested treatments for the different types of RVO, and their complications. Isovolaemic haemodilution is of limited benefit and should be avoided in patients with concurrent cardiovascular, renal, or pulmonary morbidity. Evidence to date does not support any therapeutic benefit from radial optic neurotomy, optic nerve decompression, or arteriovenous crossing sheathotomy on its own. Vitrectomy combined with intravenous thrombolysis may offer promise for central RVO. Similarly, vitrectomy combined with arteriovenous sheathotomy intravenous tissue plasminogen activator may offer benefits for branch RVO. RVOs occur at significantly high frequency to allow future prospective randomised controlled studies to be conducted to evaluate the role of different therapeutic modalities singly or in combination.

1 November 2016 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
MMMarco U. Morales
Marco U. Morales
SSSaker Saker
Saker Saker
CWCraig Wilde
Craig Wilde
CPCarlo Pellizzari
Carlo Pellizzari
APAristophanes Pallikaris
Aristophanes Pallikaris
Winfried AmoakuWinfried Amoaku
Winfried Amoaku
Purpose: The purpose of this study was to establish a normal reference database for fixation stability measured with the bivariate contour ellipse area (BCEA) in the Macular Integrity Assessment (MAIA) microperimeter. Methods: Subjects were 358 healthy volunteers who had the MAIA examination. Fixation stability was assessed using two BCEA fixation indices (63% and 95% proportional values) and the percentage of fixation points within 1° and 2° from the fovea (P1 and P2). Statistical analysis was performed with linear regression and Pearson's product moment correlation coefficient. Results: Average areas of 0.80 deg2 (min = 0.03, max = 3.90, SD = 0.68) for the index BCEA@63% and 2.40 deg2 (min = 0.20, max = 11.70, SD = 2.04) for the index BCEA@95% were found. The average values of P1 and P2 were 95% (min = 76, max = 100, SD = 5.31) and 99% (min = 91, max = 100, SD = 1.42), respectively. The Pearson's product moment test showed an almost perfect correlation index, r = 0.999, between BCEA@63% and BCEA@95%. Index P1 showed a very strong correlation with BCEA@63%, r = −0.924, as well as with BCEA@95%, r = −0.925. Index P2 demonstrated a slightly lower correlation with both BCEA@63% and BCEA@95%, r = −0.874 and −0.875, respectively. Conclusions: The single parameter of the BCEA@95% may be taken as accurately reporting fixation stability and serves as a reference database of normal subjects with a cutoff area of 2.40 ± 2.04 deg2 in MAIA microperimeter. Translational Relevance: Fixation stability can be measured with different indices. This study originates reference fixation values for the MAIA using a single fixation index.