Vinayak J. Bhat

Mr. Vinayak J. Bhat

Leibniz IPHT
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SVSahitya Vegesna
Sahitya Vegesna
VBVinayak J. Bhat
Vinayak J. Bhat
DBDanilo Bürger
Danilo Bürger
JDJan Dellith
Jan Dellith
ISIlona Skorupa
Ilona Skorupa
HSHeidemarie Schmidt
Heidemarie Schmidt
A novel small signal equivalent circuit model is proposed in the inversion regime of metal/(ZnO, ZnMnO, and ZnCoO) semiconductor/Si3N4 insulator/p-Si semiconductor (MSIS) structures to describe the distinctive nonlinear frequency dependent capacitance (C-F) and conductance (G-F) behaviour in the frequency range from 50 Hz to 1 MHz. We modelled the fully depleted ZnO thin films to extract the static dielectric constant (εr) of ZnO, ZnMnO, and ZnCoO. The extracted enhancement of static dielectric constant in magnetic n-type conducting ZnCoO (εr ≥ 13.0) and ZnMnO (εr ≥ 25.8) in comparison to unmagnetic ZnO (εr = 8.3–9.3) is related to the electrical polarizability of donor-type bound magnetic polarons (BMP) in the several hundred GHz range (120 GHz for CdMnTe). The formation of donor-BMP is enabled in n-type conducting, magnetic ZnO by the s-d exchange interaction between the electron spin of positively charged oxygen vacancies $${V}_{o}^{+}$$Vo+ in the BMP center and the electron spins of substitutional Mn2+ and Co2+ ions in ZnMnO and ZnCoO, respectively. The BMP radius scales with the Bohr radius which is proportional to the static dielectric constant. Here we show how BMP overlap can be realized in magnetic n-ZnO by increasing its static dielectric constant and guide researchers in the field of transparent spintronics towards ferromagnetism in magnetic, n-ZnO.

24 August 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
VBVinayak J. Bhat
Vinayak J. Bhat
DBDaniel Blaschke
Daniel Blaschke
EMElke Müller
Elke Müller
RERalf Ehricht
Ralf Ehricht
HSHeidemarie Schmidt
Heidemarie Schmidt
We present a novel and easy approach using a silicon-based impedance chip to determine the concentration of the given aqueous buffer solution. An accurate determination of the post-dilution concentration of the buffers is necessary for ensuring optimal buffer capacity, pH stability, and to assess solution reproducibility. In this study, we focused on phosphate buffer as the test liquid to achieve precise post-dilution concentration determinations. The impedance chip consisting of a top gold ring electrode, where a test volume of 20 μL to 30 μL of phosphate buffer was introduced for impedance measurements within the frequency range of 40 Hz to 1 MHz. For impedance investigation, we used phosphate buffers with three different pH values, and the impedance was measured after diluting the phosphate buffers to a concentration of 1.00 M, 0.75 M, 0.50 M, 0.25 M, 0.10 M, 0.05 M, and 0.01 M. In order to analyze the distinctive changes in the measured impedance, an equivalent circuit was proposed and modeled. From the impedance modeling, we report that the circuit parameter RAu/Si showed exponential dependence on the concentration of phosphate buffer and no dependence on the pH values of the phosphate buffer and on the added volume inside the ring electrode. The proposed silicon-based impedance chip is quick and uses reduced liquid volume for post-dilution concentration measurements of buffers and has perspective applications in the pharmaceutical and biological domains for regulating, monitoring, and quality control of the buffers.

Verified
Journal Article
Open access
PDF file
VBVinayak J. Bhat
Vinayak J. Bhat
SVSahitya Vegesna
Sahitya Vegesna
KKKiani Kiani
Kiani Kiani
XZXianyue Zhao
Xianyue Zhao
DBDaniel Blaschke
Daniel Blaschke
HSHeidemarie Schmidt
Heidemarie Schmidt
Using two different types of impedance biochips (PS5 and BS5) with ring top electrodes, a distinct change of measured impedance has been detected after adding 1–5 µL (with dead or live Gram-positive Lysinibacillus sphaericus JG-A12 cells to 20 µL DI water inside the ring top electrode. We relate observed change of measured impedance to change of membrane potential of L. sphaericus JG-A12 cells. In contrast to impedance measurements, optical density (OD) measurements cannot be used to distinguish between dead and live cells. Dead L. sphaericus JG-A12 cells have been obtained by adding 0.02 mg/mL of the antibiotics tetracycline and 0.1 mg/mL chloramphenicol to a batch with OD0.5 and by incubation for 24 h, 30 °C, 120 rpm in the dark. For impedance measurements, we have used batches with a cell density of 25.5 × 108 cells/mL (OD8.5) and 270.0 × 108 cells/mL (OD90.0). The impedance biochip PS5 can be used to detect the more resistive and less capacitive live L. sphaericus JG-A12 cells. Also, the impedance biochip BS5 can be used to detect the less resistive and more capacitive dead L. sphaericus JG-A12 cells. An outlook on the application of the impedance biochips for high-throughput drug screening, e.g., against multi-drug-resistant Gram-positive bacteria, is given.