To compare different parameters of the sphericity index of the ablation zone following microwave ablation (MWA) on cirrhotic- and healthy-liver parenchyma in a series of patients treated with the same MWA system. Institutional database research identified 46 patients (77 lesions) who underwent MWA. “Cirrhotic liver group” (CLG) included 35 hepatocellular carcinoma lesions; “healthy liver group” (HLG) included 42 metastatic lesions. The long axis (LAD), short axis 1 (SAD-1) and 2 (SAD-2), the mean SAD-1 and SAD-2 (mSAD) diameter (in mm) and the mean sphericity (mSPH) index of the ablation zones were evaluated for each treated lesion in both groups from baseline to follow-up. A mixed model analysis of variance reported significant main effect of group on SAD-1 (p = 0.023), SAD-2 (p = 0.010) and mSAD (p = 0.010), with HLG showing lower values compared to CLG. No differences were detected on the LAD (pFDR = 0.089; d = 0.45), and mSPH (pFDR = 0.148, d = 0.40) between the two groups. However, a significant main effect of time was found on LAD (p < 0.001), SAD-1 (p < 0.001), SAD-2 (p < 0.001) and mSAD (p < 0.001), with decreased values in all indices at follow-up compared to baseline. A significant group by time interaction was observed on mSPH (p = 0.044); HLG had significantly lower mSPH at follow-up where CLG did not show any significant change. Our findings indicate that although in cirrhotic liver short axis diameter of the MWA zone seems to be significantly longer, this has no effect on the sphericity index which showed no significant difference between cirrhotic vs. healthy liver lesions. On the contrary, on one month follow-up ablation zones tend to become significant more ellipsoid in healthy whilst remains stable in cirrhotic liver.
Prostate cancer (PCa) is the most common malignancy in men. Precise grading is crucial for the effective treatment approaches of PCa. Machine learning (ML) applied to biparametric Magnetic Resonance Imaging (bpMRI) radiomics holds promise for improving PCa diagnosis and prognosis. This study investigated the efficiency of seven ML models to diagnose the different PCa grades, changing the input variables. Our studied sample comprised 214 men who underwent bpMRI in different imaging centers. Seven ML algorithms were compared using radiomic features extracted from T2-weighted (T2W) and diffusion-weighted (DWI) MRI, with and without the inclusion of Prostate-Specific Antigen (PSA) values. The performance of the models was evaluated using the receiver operating characteristic curve analysis. The models’ performance was strongly dependent on the input parameters. Radiomic features derived from T2WI and DWI, whether used independently or in combination, demonstrated limited clinical utility, with AUC values ranging from 0.703 to 0.807. However, incorporating the PSA index significantly improved the models’ efficiency, regardless of lesion location or degree of malignancy, resulting in AUC values ranging from 0.784 to 1.00. There is evidence that ML methods, in combination with radiomic analysis, can contribute to solving differential diagnostic problems of prostate cancers. Also, optimization of the analysis method is critical, according to the results of our study.
Background and Objectives: The aim of the present study was to report the safety and efficacy of percutaneous navigation under local anesthesia for computed tomography-guided microwave ablation of malignant liver lesions located in the hepatic dome. Patients with primary and secondary malignant liver lesions located in the hepatic dome who underwent percutaneous computed tomography-guided microwave ablation using a computer-assisted navigation system under local anesthesia were prospectively evaluated. The primary objective was technical success. Materials and Methods: The sample consisted of 10 participants (16 lesions) with a mean age of 60.60 years (SD = 9.25 years) and a mean size of 20.37 ± 7.29 cm, and the mean follow-up time was 3.4 months (SD = 1.41) months. Results: Primary technical success was 93.75%. Tumor remnant was noticed at one month follow-up in a single metastatic lesion, which was re-treated with an ablation session, and no tumor remnant was depicted in the subsequent imaging follow-up (secondary technical success 100%). Grade I self-limited complications (according to the CIRSE classification system) included small pleural effusion (n = 1) and minor bleeding post antenna removal (n = 1) requiring nothing but observation. Conclusions: the findings of the present study indicate that percutaneous navigation under local anesthesia is a safe and efficacious approach for computed tomography-guided microwave ablation of malignant liver lesions located in the hepatic dome. Large randomized controlled studies are warranted to observe treatment effectiveness and compare the results with those of other options.
Purpose. To retrospectively evaluate the effectiveness of intra-articular application of Sluijter-Teixera Poisson pulsed radiofrequency (STP PRF) in knee osteoarthritis symptomatic patients with chronic pain refractory to conservative therapies. Materials and Methods. Institutional database research of two centers identified 39 cases of knee osteoarthritis patients treated with intra-articular STP PRF. Pain prior and one-week and one-, three-, six-, and twelve-month post-STP PRF was compared by means of a numeric visual scale (NVS) questionnaire. Cardiovascular and Interventional Radiological Society of Europe (CIRSE) classification system was used for complications reporting. Mean patient age was 71.59 ± 11.99 years, mean body mass index was 30.23 ± 4.69, and male/female ratio was 9/30. Results. Mean baseline pain score was 8.31 ± 1.70 NVS units. This was reduced to a mean value of 0.90 ± 1.50 NVS units one-week post-RF, 1.08 ± 1.53 at one month, 1.54 ± 1.88 at three months, 2.33 ± 2.17 at six months, and 3.23 ± 2.23 at 12 months of follow-up . Pain decrease of more than 4 NVS units was noticed in 35/39 knees (89.7%) at first week, 36/39 knees (92.3%) at first month, 35/39 knees (89.7%) at three months, 32/39 knees (82.1%) at six months, and 25/39 knees (64.1%) at one year. There was no recurrence during the follow-up. No complication was observed. Conclusions. Percutaneous, intra-articular application of STP PRF is an effective and safe technique for chronic pain reduction in patients with knee osteoarthritis. Results seem to be reproducible and long lasting with significant patient satisfaction at 12-month follow-up.
11 July 2022 in Egyptian Journal of Radiology and Nuclear Medicine
Background: Liver lobe anatomic variations are uncommon and may often cause clinical difficulties. We present a trauma patient with a previously unreported (to our knowledge) hepatic morphology, which was initially misdiagnosed as a possible perisplenic hematoma, leading to unnecessary further investigations. Case presentation: A 32-year-old male patient was brought to our hospital’s emergency department following a low-energy motor vehicle accident. The patient was ambulatory, had a GCS of 15/15, and appeared hemodynamically stable with normal hematocrit (Hct)/hemoglobin (Hb) blood counts. No clinical signs/symptoms of bleeding were noted, and no significant complaints were documented, besides minor left flank tenderness with overlying abrasions. The patient's past medical history was insignificant. FAST (Focused Assessment with Sonography for Trauma) scan performed gave the impression of a crescent-shaped hypoechoic lesion/collection medially to the spleen, raising suspicion of a perisplenic hematoma. Subsequent computed tomography (CT) scan displayed no trauma-related findings, while the suspected hematoma was seen to correspond to variant left hepatic lobe morphology. Conclusion: The “hiding beaver tail liver” (HBTL) is a hepatic morphology variant encountered when the lateral part of the left liver lobe (beaver’s tail) extends across the midline and lies medially to the visceral surface of the spleen, following an acute angulation (in hiding). As it can mimic true pathology, familiarity with this morphology is crucial to avoid false diagnosis and unnecessary investigations.
About Me
Radiology Resident
2nd Department of Radiology Dpt, University General Hospital "ATTIKON"
Medical School, National and Kapodistrian University of Athens
Radiology Resident
2nd Department of Radiology Dpt, University General Hospital "ATTIKON"
Medical School, National and Kapodistrian University of Athens