Paweł Zawadzki

Mr. Paweł Zawadzki

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2022 in Renewable Energy
Verified
Journal Article
Closed access
ABAndrzej Boduch
Andrzej Boduch
KMKrzysztof Mik
Krzysztof Mik
Rui CastroRui Castro
Rui Castro
PZPaweł Zawadzki
Paweł Zawadzki

22 September 2023 in Atmospheric Environment
Verified
Journal Article
Open access
AHAmirhossein Hassani
Amirhossein Hassani
SBSebastian Bykuć
Sebastian Bykuć
PSPhilipp Schneider
Philipp Schneider
PZPaweł Zawadzki
Paweł Zawadzki
PCPatryk Chaja
Patryk Chaja
NCNúria Castell
Núria Castell

27 August 2022 in Renewable Energy
Verified
Journal Article
Closed access
KMKrzysztof Mik
Krzysztof Mik
PZPaweł Zawadzki
Paweł Zawadzki
JTJan Tarłowski
Jan Tarłowski
SBSebastian Bykuć
Sebastian Bykuć

16 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
KMKrzysztof Mik
Krzysztof Mik
PZPaweł Zawadzki
Paweł Zawadzki
JTJan Tarłowski
Jan Tarłowski
MBMarcin Bugaj
Marcin Bugaj
PGPiotr Grygiel
Piotr Grygiel
SBSebastian Bykuć
Sebastian Bykuć
Dynamic growth of photovoltaic capacity in Poland encourages many entities to invest in photovoltaic systems. However, in the case of buildings with low roof-bearing capacity it can be problematic or even impossible to mount conventional PV modules due to their relatively high weight. Hence, the use of lightweight PV modules is a potential solution. In this paper four different prototype silicon lightweight modules of novel structure manufactured by the Xdisc S.A have been investigated in terms of their electrical and thermal features. The measurements showed that all prototypes have efficiency exceeding 19.5% and power in range of 214 to 242 Wp at standard test conditions. Their area density is about 3.5 kg/m2 which is typical for lightweight modules. In turn, the Power-to-Weight Ratio exceeds 40 W/kg threshold and in one case reaches almost 58 W/kg. Thanks to the measurements, the prototypes could be modelled in PVsyst (PVsyst SA, Satigny, Switzerland). The performed simulations of an example PV system revealed that installations based on prototypes have comparable performance to a conventional installation. Nevertheless, at current prices they are less profitable than the standard system and it shows the need for future cost reductions in the manufacturing process. The proposed materials selection may be the starting point for search of inexpensive substitutes of these materials which still conserve modules high performance. A system based on the prototypes can still prove advantageous when simplicity and promptness outweigh higher initial costs.

13 June 2025 in Energy Reports
Verified
Journal Article
Open access
BABahman Ahmadi
Bahman Ahmadi
GHGerwin Hoogsteen
Gerwin Hoogsteen
PZPaweł Zawadzki
Paweł Zawadzki
MGMarco E. T. Gerards
Marco E. T. Gerards
WRWeronika Radziszewska
Weronika Radziszewska
JHJohann Hurink
Johann Hurink

4 July 2025 in Air Quality, Atmosphere & Health
Verified
Journal Article
Open access
PDF file
VSVasileios Salamalikis
Vasileios Salamalikis
AHAmirhossein Hassani
Amirhossein Hassani
PZPaweł Zawadzki
Paweł Zawadzki
SBSebastian Bykuć
Sebastian Bykuć
Nuria CastellNuria Castell
Nuria Castell
Fine particulates observed indoors exhibit high variability, influenced by both indoor emission sources and the infiltration of outdoor particles through open spaces and the incomplete building insulation. This study examines the relationship between indoor and outdoor PM2.5 levels in Legionowo, Poland, using data from low-cost air quality sensors operated by citizens. The indoor PM2.5 was lower than outdoor levels (median PM2.5: 1.9–17.3 μg m–3 indoors and 6.7–27.9 μg m–3 outdoors), with occasional peaks attributed to potential indoor emission sources. Statistical analysis identified emission events—particularly during cooking and household-heating periods—occurring more frequently from October to April. During this period, nearly 17% of indoor PM2.5 measurements were attributed to indoor emission sources after 18:00 LT, representing a 7% increase compared to the May–September period. In the absence of indoor sources, outdoor particles accounted for 29% to 75% of indoor concentrations, highlighting the significance of infiltration. This research emphasizes how citizen-generated data using low-cost sensors, after post-processing, can provide decision-ready information as for example outdoor particles’ infiltration factors for each building. The knowledge of the infiltration factor enables the determination of the contribution of indoor and outdoor sources to each resident’s exposure to airborne PM. This information can help decision-makers in devising interventions such as prioritizing indoor ventilation, reducing indoor activities resulting in increased exposure, and addressing outdoor pollution sources.