This paper proposes a practical calibration solution for estimating the boresight and lever-arm parameters of the sensors mounted on a Mobile Mapping System (MMS). On our MMS devised for conducting the calibration experiment, three network video cameras, one mobile laser scanner, and one Global Navigation Satellite System (GNSS)/Inertial Navigation System (INS) were mounted. The geometric relationships between three sensors were solved by the proposed calibration, considering the GNSS/INS as one unit sensor. Our solution basically uses the point cloud generated by a 3-dimensional (3D) terrestrial laser scanner rather than using conventionally obtained 3D ground control features. With the terrestrial laser scanner, accurate and precise reference data could be produced and the plane features corresponding with the sparse mobile laser scanning data could be determined with high precision. Furthermore, corresponding point features could be extracted from the dense terrestrial laser scanning data and the images captured by the video cameras. The parameters of the boresight and the lever-arm were calculated based on the least squares approach and the precision of the boresight and lever-arm could be achieved by 0.1 degrees and 10 mm, respectively.
Geometric correction of SAR satellite imagery is the process to adjust the model parameters that define the relationship between ground and image coordinates. To achieve sub-pixel geolocation accuracy, the adoption of the appropriate geometric correction model and parameters is important. Until now, various geometric correction models have been developed and applied. However, it is still difficult for general users to adopt a suitable geometric correction models having sufficient precision. In this regard, this paper evaluated the orbit-based and time-offset-based models with an error simulation. To evaluate the geometric correction models, Radarsat-1 images that have large errors in satellite orbit information and TerraSAR-X images that have a reportedly high accuracy in satellite orbit and sensor information were utilized. For Radarsat-1 imagery, the geometric correction model based on the satellite position parameters has a better performance than the model based on time-offset parameters. In the case of the TerraSAR-X imagery, two geometric correction models had similar performance and could ensure sub-pixel geolocation accuracy.
In this paper, we propose a method to regenerate Rational Polynomial Coefficients (RPCs) using KOMPSAT-3A imagery and to reduce the geolocation error using minimum ground control points (GCPs). To estimate the new RPCs, the physical sensor model fitted to KOMPSAT-3A imagery was utilized and virtual GCPs over the study area were created. The size of the virtual grid used was 20x20x20. To remove the sensor-related errors in physical sensor model, three different image correction models (image coordinate translation model, shift and drift model, and affine transformation model) were additionally applied. We evaluated our proposed method in two areas within Korea, one in urban (Seoul) and one in rural (Goheung) areas. The results showed that there was a significant improvement after applying the suggested approach in the two areas. The image coordinate translation model is suggested in terms of GCP requirement and expected errors estimated from the error propagation analysis using Gauss–Markov Model (GMM).
31 December 2015 in Journal of the Korean Society of Hazard Mitigation
When a new spaceborne imaging mission is launched and operated, the generation of the rational function model (RFM), which simplifies the geometric relationship between the ground targets and image coordinates, is one of the important mechanisms to unify the image data with the other geospatial datasets. In this paper, the performance of the generated RFM for the KOMPSAT-5 satellite imagery was evaluated. High-resolution KOMPSAT-5 images whose spatial resolutions are about 1 meter were used for the experiments. During the RFM generation process, the general least squares adjustment and the Tikhonov regularization with the L-curve optimization were applied to initialize and optimize the RFM coefficients. From the physical sensor model for KOMPSAT-5, virtual grids were created and utilized as the control points for generating the RFM. Furthermore, appropriate sizes of virtual grids and the number of elevation layers were proposed. As a result of the experiments, an RFM having a precision better than 10−9 pixels could be generated from a virtual grid of 10 × 10 × 5. Moreover, the reference coordinate system of the control points did not significantly affect the performance of the RFM generation process.