Mojtaba Navvab

Dr. Mojtaba Navvab


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in Journal of Green Building
Verified
Journal Article
Open access
JVJatuwat Varodompun
Jatuwat Varodompun
MNMojtaba Navvab
Mojtaba Navvab
In Heating Ventilating and Air Conditioning (HVAC) systems, ventilation strategies impact building energy consumption, occupants' thermal comfort and Indoor Air Quality (IAQ). Ventilation strategies such as Mixing Jet Ventilation (MJV), Displacement Ventilation (DV), and Impinging Jet Ventilation (IJV) are operated on the different principals. MJV relies on dilution, while DV and IJV rely on both dilution and stratification. Due to climatic variation, ventilation strategies must be operated under different cooling and heating load scenarios. Typically, each ventilation strategy controls the indoor environment through a single adequate flow rate with suitable supply parameters such as temperature, pollutant concentration, vapor, velocity, etc. Hence, the indoor thermal and IAQ condition are independently impacted. A room with excellent thermal condition is possible to have poor IAQ. Given this limitation, vast air flow variables, and occupants' activities, the performances evaluation of these strategies are complicated. In this study, three ventilation strategies, MJV, DV, and IJV are thoroughly investigated. The Computational Fluid Dynamics (CFD) simulation was mainly utilized to handle the complexity of this study. The parametric studies of 48 CFD simulations are presented. Referring to ASHRAE RP-1133, the experimental data from a specially built HVAC-IEQ laboratory was used to validate the CFD data. The research results indicate both advantages and disadvantages in all three strategies. In addition, there is no single strategy that can perform excellently in all indexes. Using the well-known index called ventilation effectiveness (VEF), DV performs outstandingly. However, under a newly proposed index called ventilation performances, DV fails because the stratification discomfort exceeds 36% of room area. MJV suffers from low VEF and excessive draft. However, the IAQ of MJV is not as poor as expected. IJV can be an alternative especially for space where sleeping and sitting activities dominate. IJV can conserve HVAC energy, while maintaining good IAQ. Compared to DV, although VEF is lower, stratification discomfort is minimized to 24%–12% (depending on supply velocity). Overall, this study demonstrates that ventilation strategies are the key to enhance IAQ. Therefore, the utilization of an appropriate ventilation strategy might increase, Leadership in Energy and Environmental Design (LEED) score, particularly for Indoor Environmental Quality, Innovation and Design Process, and Energy and Atmospheric categories.

1 October 2006 in LEUKOS
Verified
Journal Article
Closed access
MIMehlika N. Inanici
Mehlika N. Inanici
MNMojtaba Navvab
Mojtaba Navvab

28 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
ASAzadeh Omidfar Sawyer
Azadeh Omidfar Sawyer
MNMojtaba Navvab
Mojtaba Navvab
Dan WeissmanDan Weissman
Dan Weissman
GJGuanzhou Ji
Guanzhou Ji
This concept paper illustrates a new simulation method to assess how building facades distribute light into interior spaces and how data from simulation studies can inform design for better facade performance. Facade photometry, a term developed by the authors, uses annual simulations and localized weather data to create temporally based illuminance and luminance distributions. This photometric chart is a unique signature of a particular facade design measured at a specific point in a specific climate. By linking data from the daylight simulation to the facade, the areas of the facade that need to be adjusted for improved performance are highlighted. Facade photometry is intended to allow designers to easily compare the performance of complex building geometry and daylight control systems, thus becoming an efficient tool to further aid designers in creating highly energy-efficient, high-performance, and comfortable building facades.

1 July 2007 in LEUKOS
Verified
Journal Article
Closed access
CLCecilia Sik Lányi
Cecilia Sik Lányi
Zsolt Tibor KosztyánZsolt Tibor Kosztyán
Zsolt Tibor Kosztyán
BKBalázs Kránicz
Balázs Kránicz
JSJános Schanda
János Schanda
MNMojtaba Navvab
Mojtaba Navvab
Color is becoming a key issue in many e-commerce products. This made it necessary to develop a color course easily accessible from the Internet or distributed on CD-ROM. This article describes the advantages of the electronic approach – compared to class-room demonstrations – to bring the fundamentals of colorimetry to the student with the help of demonstrations.

1 January 2012
Verified
Book Chapter
Closed access
PDF file
THTheodore W. Hall
Theodore W. Hall
MNMojtaba Navvab
Mojtaba Navvab
EMEric Maslowski
Eric Maslowski
SPSean Petty
Sean Petty

19 February 2014 in Lighting Research & Technology
Verified
Journal Article
Open access
MNMojtaba Navvab
Mojtaba Navvab