The WAW-TACE dataset contains baseline multiphase abdominal CT images from 233 treatment-naive patients with hepatocellular carcinoma treated with transarterial chemoembolization and includes 377 handcrafted liver tumor masks, automated segmentations of multiple internal organs, extracted radiomics features, and corresponding extensive clinical data. The dataset can be accessed at https://zenodo.org/records/12741586 .
Aim: To determine inter-reader agreement in categorization of imaging features using the Liver Imaging Reporting and Data System (LI-RADS) treatment response (LR-TR) algorithm in patients with hepatocellular carcinoma (HCC) treated with conventional transarterial chemoembolization (cTACE). Methods: Two radiologists used the LR-TR algorithm to assess 112 computed tomography (CT) examinations of 102 patients treated with cTACE. The inter-observer agreement in categorization of LR-TR features was assessed using kappa (κ) statistics. Results: There was substantial inter-observer agreement between the two reviewers using the LR-TR algorithm (κ = 0.70; 95% CI 0.58–0.81). The two reviewers categorized tumors as non-viable in 37 (33.0%) and 39 (34.8%) of 112 examinations, viable in 58 (51.8%) and 62 (55.4%) examinations, and equivocal in 18 (16.1%) and 11 (9.8%) examinations, respectively. There was almost perfect inter-observer agreement for the LR-TR non-viable category (κ = 0.80; 95% CI 0.68–0.92), substantial agreement for the viable category (κ = 0.78 95% CI 0.67–0.90), and fair agreement for the equivocal category (κ = 0.25; 95% CI 0.02–0.49). Conclusion: The LR-TR algorithm conveys high degrees of inter-observer agreement for the assessment of CT imaging features in the viable and non-viable categories. Further refinement of indeterminate features may be necessary to improve the correct categorization of equivocal lesions. Graphic
Objective: Endovascular surgery requires accurate measurement of parameters such as pressure, temperature, and biomarkers within vessels for real-time tissue response monitoring and ensuring targeted therapeutic interventions. However, the availability of small tip-based sensors capable of precise application, for example, navigating an aneurysm's lumen, is limited. With their capabilities for real-time analysis, flexibility, and biocompatibility, optical fiber sensors (OFS) hold promise in addressing this need. This proof-of-concept study investigates the feasibility of OFS in endovascular surgery scenarios. Methods: The sensor is based on a single-mode silica fiber with an interferometric forward-facing thin-film tip. The thin-film materials may be tailored for detecting various physical parameters and, when functionalized, also specific analytes. Materials applied in this sensor are thin metal oxides deposited using magnetron sputtering. A full-scale 3D-printed vascular model was employed to simulate endovascular setup. Results: The experiments showed the high mechanical robustness of the approach, i.e., the sensor maintained functionality while being maneuvered through the endovascular model. The forward-facing tip remained intact and worked adequately, ensuring consistent and stable readouts. Moreover, the fiber showed sufficient flexibility, with no significant bending loss observed during simulations. Finally, the performance of the OFS in bovine serum samples was assessed. The sensor performed well in serum, and the results suggest that low-concentration serum may be used to reduce nonspecific surface interactions. Conclusion: Overall, this OFS system offers a promising solution for endovascular surgery and other biomedical applications, allowing for precise and on-the-spot analysis. Significance: Our study pioneers the feasibility of thin-film interferometric label-free OFS with a forward-facing sensitive area for sensing during endovascular procedures.