Biswajit Ray

Dr. Biswajit Ray

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
SSShikha Singh
Shikha Singh
KMKheyanath Mitra
Kheyanath Mitra
ASAparna Shukla
Aparna Shukla
RSRajshree Singh
Rajshree Singh
RGRavi Kumar Gundampati
Ravi Kumar Gundampati
BRBiswajit Ray
Biswajit Ray

16 November 2017 in ACS Biomaterials Science & Engineering
Verified
Journal Article
Closed access
DPDinesh K. Patel
Dinesh K. Patel
SSSudipta Senapati
Sudipta Senapati
PMPunita Mourya
Punita Mourya
MSMadan M. Singh
Madan M. Singh
VAVinod K. Aswal
Vinod K. Aswal
PMPralay Maiti
Pralay Maiti

8 April 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SHSumit Kumar Hira
Sumit Kumar Hira
AMAvnish Kumar Mishra
Avnish Kumar Mishra
BRBiswajit Ray
Biswajit Ray
PMPartha Pratim Manna
Partha Pratim Manna
The present study was motivated by the need to design a safe nano-carrier for the delivery of doxorubicin which could be tolerant to normal cells. PCL63-b-PNVP90 was loaded with doxorubicin (6 mg/ml), and with 49.8% drug loading efficiency; it offers a unique platform providing selective immune responses against lymphoma. In this study, we have used micelles of amphiphilic PCL63-b-PNVP90 block copolymer as nano-carrier for controlled release of doxorubicin (DOX). DOX is physically entrapped and stabilized in the hydrophobic cores of the micelles and biological roles of these micelles were evaluated in lymphoma. DOX loaded PCL63-b-PNVP90 block copolymer micelles (DOX-PCL63-b-PNVP90) shows enhanced growth inhibition and cytotoxicity against human (K-562, JE6.1 and Raji) and mice lymphoma cells (Dalton's lymphoma, DL). DOX-PCL63-b-PNVP90 demonstrates higher levels of tumoricidal effect against DOX-resistant tumor cells compared to free DOX. DOX-PCL63-b-PNVP90 demonstrated effective drug loading and a pH-responsive drug release character besides exhibiting sustained drug release performance in in-vitro and intracellular drug release experiments. Unlike free DOX, DOX-PCL63-b-PNVP90 does not show cytotoxicity against normal cells. DOX-PCL63-b-PNVP90 prolonged the survival of tumor (DL) bearing mice by enhancing the apoptosis of the tumor cells in targeted organs like liver and spleen.

23 June 2011 in Macromolecules
Verified
Journal Article
Closed access
CBChandra Biswas
Chandra Biswas
VPVijay Kumar Patel
Vijay Kumar Patel
NVNiraj Kumar Vishwakarma
Niraj Kumar Vishwakarma
VTVimal K. Tiwari
Vimal K. Tiwari
BMBiswajit Maiti
Biswajit Maiti
BRBiswajit Ray
Biswajit Ray

6 November 2017 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
SSShikha Singh
Shikha Singh
KMKheyanath Mitra
Kheyanath Mitra
RSRajshree Singh
Rajshree Singh
AKArchana Kumari
Archana Kumari
SGSusanta Kumar Sen Gupta
Susanta Kumar Sen Gupta
BRBiswajit Ray
Biswajit Ray
Very recently, we have reported a novel peroxidase mimetic material, brominated graphene (GBR) having ∼3% bromine content, which, in combination with H2O2 and 3,3′,5,5′-tetramethylbenzidine (TMB), has shown the property of S2− ion recognition (Anal. Chem., 2017, 89, 783–791). In the present work, we further have investigated the kinetic assay and colorimetric sensing ability of GBR towards hydrogen peroxide (H2O2) and glucose. The Michaelis–Menten constants (Km) and maximum initial velocities (Vmax) of GBR have been found to be 10.98 mM and 3.60 × 10−8 M s−1, respectively, for H2O2 and 0.83 mM and 0.68 × 10−8 M s−1, respectively, for TMB. A sensor combining TMB and GBR has been fabricated, which, upon addition to H2O2 or glucose with glucose oxidase solution at pH 4.48, showed colorimetrically a significant increase in the oxidation of TMB. The fabricated sensor system has displayed linearity for H2O2 and glucose estimation in the range 0.50–5.00 mM and 40–100 mM, respectively, and the corresponding limits of detection are found to be 0.417 and 28.41 mM, respectively. The present sensor system is also highly reproducible and selective. The results of real samples using this colorimetric method have been found to be comparable with the conventional auto-analyser method.

15 October 2009 in Polymer Bulletin
Verified
Journal Article
Closed access
PDF file
VPVijay Kumar Patel
Vijay Kumar Patel
AMAvnish Kumar Mishra
Avnish Kumar Mishra
NVNiraj Kumar Vishwakarma
Niraj Kumar Vishwakarma
CBChandra Biswas
Chandra Biswas
BRBiswajit Ray
Biswajit Ray