Jon Tschudi

Mr. Jon Tschudi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2021 in Foods
Verified
Journal Article
Open access
PDF file
Jens WoldJens Wold
Jens Wold
marion farrellmarion farrell
marion farrell
PAPetter Vejle Andersen
Petter Vejle Andersen
JTJon Tschudi
Jon Tschudi
Dry matter (DM) content is one of the most important quality features of potatoes. It defines the physical properties of the potatoes and determines what kind of product the potatoes can be used for. This paper presents the results obtained by a novel prototype NIR (near-infrared) instrument designed to measure DM content in single potatoes in process. The instrument is based on interaction measurements to measure deeper into the potatoes. It measures rapidly, up to 50 measurements per second, allowing several moving potatoes to be measured per second. The instrument also enables several interactance distances to be recorded for each measurement. The instrument was calibrated based on three different potato varieties and the calibration measurements were done in a process plant, making the calibration model suitable for in-line use. A good calibration for DM was obtained by partial least squares regression (RMSECV = 0.78% DM, R2 = 0.91). The instrument was tested in-line in the process plant and several batches of potatoes were monitored for the estimation of the DM distribution per batch. Accuracy of DM determination as function of measurement position on the potato was studied, and results indicate that NIR scans along the center part of the potatoes give slightly better results compared to scans taken on either side of the center. Small differences in optical measurement geometry influence the accuracy of the calibration models, underlining the importance of optimizing instrument design for successful measurements.

9 January 2024 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Open access
Jens WoldJens Wold
Jens Wold
PAPetter Vejle Andersen
Petter Vejle Andersen
KAKjersti Aaby
Kjersti Aaby
SRSiv Fagertun Remberg
Siv Fagertun Remberg
AHAnders Hansen
Anders Hansen
JTJon Tschudi
Jon Tschudi
Autonomous field robots are being developed for picking of fruit, where each fruit needs to be individually graded and handled. There is therefore a need for rapid and non-destructive sensing to measure critical fruit quality parameters. In this article we report how total soluble solids (TSS), a measure for total sugar content, can be measured in strawberries in the field by non-contact near-infrared (NIR) interaction spectroscopy. A specially designed prototype system working in the wavelength range 760-1080 nm was tested for this purpose. This novel instrument was compared with a commercial handheld NIR reflection instrument working in the range 900-1600 nm. The instruments were calibrated in the lab using data collected from 200 strawberries of two varieties and tested in a strawberry field on 50 berries in 2022 and 100 berries in 2023. Both systems performed well during calibration with root mean square errors of cross validation for TSS around 0.49 % and 0.57 %, for interaction and reflection, respectively. For prediction of TSS in new berries in 2023, the interaction system was superior, with a prediction error of 1.0 % versus 8.1 % for the reflection system, most likely because interaction probes deeper into the berries. The results suggest that interaction measurements of average TSS are more robust and would most likely require less calibration maintenance compared to reflection measurements. The non-contact feature is important since it reduces the spread of diseases and physical damage to the berries.

24 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JHJie Hou
Jie Hou
SNSiri Schøne Ness
Siri Schøne Ness
JTJon Tschudi
Jon Tschudi
marion farrellmarion farrell
marion farrell
RVRune Veddegjerde
Rune Veddegjerde
RSRunar Strand-Amundsen
Runar Strand-Amundsen
A porcine model was used to investigate the feasibility of using VIS-NIR spectroscopy to differentiate between degrees of ischemia–reperfusion injury in the small intestine. Ten pigs were used in this study and four segments were created in the small intestine of each pig: (1) control, (2) full arterial and venous mesenteric occlusion for 8 h, (3) arterial and venous mesenteric occlusion for 2 h followed by reperfusion for 6 h, and (4) arterial and venous mesenteric occlusion for 4 h followed by reperfusion for 4 h. Two models were built using partial least square discriminant analysis. The first model was able to differentiate between the control, ischemic, and reperfused intestinal segments with an average accuracy of 99.2% with 10-fold cross-validation, and the second model was able to discriminate between the viable versus non-viable intestinal segments with an average accuracy of 96.0% using 10-fold cross-validation. Moreover, histopathology was used to investigate the borderline between viable and non-viable intestinal segments. The VIS-NIR spectroscopy method together with a PLS-DA model showed promising results and appears to be well-suited as a potentially real-time intraoperative method for assessing intestinal ischemia–reperfusion injury, due to its easy-to-use and non-invasive nature.

8 July 2021 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ASAlexey Stepanov
Alexey Stepanov
JTJostein Thorstensen
Jostein Thorstensen
JTJon Tschudi
Jon Tschudi
A number of common eye diseases can be diagnosed using retina images. A prominent example is diabetic retinopathy, which is a leading cause of vision loss in many developed countries.1 Other examples include glaucoma,2 age-related macular degeneration,3 retinopathy of prematurity,4 and malarial retinopathy.5 Early screening of these diseases can simplify treatment and prevent complications leading to blindness.6 Currently, this type of screening is performed at hospitals or other specialized institutions using expensive fundus camera systems that capture high-resolution retina images. In countries where this type of healthcare service is not available for the majority of the population, such screening is simply not possible. Therefore, a compact, handheld, low-cost, and easy-to-use device that enables early screening, would increase the accessibility of this technology and enable widespread early diagnosis.

28 January 2022 in arXiv
Verified
Preprint
Open access
PDF file
TDTim Dunker
Tim Dunker
JTJon Tschudi
Jon Tschudi
marion farrellmarion farrell
marion farrell
We present initial results from measurements of exhaled droplets by two singers during singing, speaking, laughing, and recitation of poetry. We also conducted measurements with a flute, a clarinet, a tuba, and only the tuba's mouthpiece. To be able to image and track droplets, we have developed and built a portable measurement set-up. We have detected droplets with diameters of approximately 50 micrometre and above. We found that for a single subject, the largest amount of droplets are produced during singing, but that laughing can produce a comparable number of droplets. Speaking and recitation of poetry do not produce as many droplets. We repeated exercises at varying distances and found that the number of detected droplets decreased rapidly with increasing distance. Most droplets we detected follow a ballistic trajectory, and hit the ground after a distance of approximately 1 m. In case of the musical instruments, we did not detect droplets exiting a tuba and only few single droplets from a flute and a clarinet. A clarinet usually points downwards, such that droplets follow a downward trajectory and hit the ground after a short distance. The situation was different when the tubist used only the mouthpiece (that is, detached from the tuba) during warm-up while partially blocking the opening with a finger: in this case, many droplets were ejected from the mouthpiece. These followed ballistic trajectories at different speeds, with some droplets exiting the measurement volume. Two important limitations of this study are that (i) the sample size is very small, such that a statistical analysis is beyond our scope; and (ii) that we cannot draw conclusions about a possible risk of infection with COVID-19 when performing any of the said activities.