Annas Fauzy

Mr. Annas Fauzy


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2023 in ACS Omega
Verified
Journal Article
Open access
AFAnnas Fauzy
Annas Fauzy
GCGuan Bang Chen
Guan Bang Chen
TLTa-Hui Lin
Ta-Hui Lin

5 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
AFAnnas Fauzy
Annas Fauzy
CYCheng-Dar Yue
Cheng-Dar Yue
CTChien-Cheng Tu
Chien-Cheng Tu
TLTa-Hui Lin
Ta-Hui Lin
Countries worldwide must dramatically reduce their emissions to achieve the goal of limiting temperature increases in line with the Paris Agreement. Involving developing countries in global actions on emission reduction will greatly enhance the effectiveness of global warming mitigation. This study investigated the feasibility of establishing a wind farm at four onshore and three offshore sites in Indonesia. Installing wind turbines with the highest hub height, largest rotor diameter, and lowest cut-in and rated wind speed in an identified area off Wetar Island presented the highest time-based availability and a capacity factor of 46%, as well as the highest power-based availability at 76%. The levelized cost of electricity at 0.082 USD/kWh was comparable to that of power generated from fossil fuels, which ranges from 0.07 to 0.15 USD/kWh in Indonesia. Increasing the feed-in-tariff for wind power from the current 0.08 USD/kWh would provide sufficient incentive for investment. Moving subsidies from fossil fuels toward renewables would facilitate the transition to low-carbon renewables without increasing the financial burden on the country.

23 June 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
AFAnnas Fauzy
Annas Fauzy
GCGuan Bang Chen
Guan Bang Chen
TLTa-Hui Lin
Ta-Hui Lin

6 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
AFAnnas Fauzy
Annas Fauzy
GCGuan Bang Chen
Guan Bang Chen
TLTa-Hui Lin
Ta-Hui Lin
Carbon monoxide (CO) is classified as a simple fuel that contains one carbon and one oxygen atom. The oxidation of CO with an oxidizer is relatively unusual, with the oxidation of CO having a slow reaction time. The addition of a small amount of “hydrogenous” species, such as H2, H2O, and CH4, will substantially increase the reaction time. This study numerically investigated and compared the effects of different hydrogenous species addition on the premixed CO/air flames, which act as the initiation of a CO/air flame, on the adiabatic flame temperature, laminar flame speed, and heat release rates at standard conditions (298 K and 1 atm pressure) using San Diego Mechanism. The results showed that the addition of critical hydrogenous species distinguished the difference between dry and wet CO/air oxidation, in which different hydrogenous species have an identical critical value. Adding different hydrogenous species and different addition ratios has an indistinguishable adiabatic flame temperature, while adding CH4 has a higher laminar flame speed distribution compared with H2 and H2O addition, respectively. Furthermore, the laminar flame speed positively correlates with the net heat release rate, which adding CH4 has a noticeable increase on the net heat release rate. Adding more hydrogenous species makes the reactant more reactive and moves the reaction zone upstream. Finally, the dominant reactions to the heat release rate are identical in different hydrogenous species addition, where R23: CO + O (+M) ⇌ CO2 (+M) becomes the most contributed reaction.

19 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MWMing-Hsun Wu
Ming-Hsun Wu
AFAnnas Fauzy
Annas Fauzy
HWHsin-Yi Wu
Hsin-Yi Wu
Co-firing methane with ammonia can decarbonize high temperature industrial processes, yet the fuel-bound nitrogen in NH3 introduces a substantial NOX penalty under pre-blended operation. This study examines ammonia lancing, the separate injection of NH3 into the plume of an established methane flame, in a 100 kW pilot-scale furnace with a commercial burner. The ammonia fuel fraction (xNH3 = 0 to 0.38) and the axial injection position (L/Db = 0 to 2.0) were varied at a fixed thermal input of 76 kW and equivalence ratio of 0.95, with pre-blending as the baseline. Lancing produced a two-zone flame structure, with a methane swirl core anchored at the burner exit and a downstream ammonia reaction zone formed by two opposed jet flames from lances angled at 45° toward the furnace axis. At xNH3 = 0.19, where the pre-blend NOX peaks, lancing reduced NOX by 60, 73, and 88% at L/Db = 0, 0.6, and ≥ 1.5, respectively. The reduction was accompanied by increases in N2O and CO, largest at L/Db ≥ 1.5 and the highest ammonia fractions, where N2O reached approximately twice the pre-blend value and CO exceeded 1000 ppm. A firing rate sweep at L/Db = 1.5 and xNH3 = 0.28 showed that N2O fell by 32% as the near burner temperature rose by 61 K, while NO increased but stayed nearly a factor of 8 below the pre-blend value. Ammonia slip remained below the FTIR detection limit of near 1.5 ppm for xNH3 ≤ 0.28 and became significant only at xNH3 = 0.38. A favorable operating window was identified for the investigated system at L/Db ≤ 0.6 with xNH3 ≤ 0.28, in which NOX is reduced by 60 to 73% and the total greenhouse gas emission remains close to the pure methane baseline.