康祐 秦

Dr. 康祐 秦

Kyushu University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2020 in Mass Spectrometry
Verified
Journal Article
Open access
PDF file
KNKohta Nakatani
Kohta Nakatani
YIYoshihiro Izumi
Yoshihiro Izumi
康秦康祐 秦
康祐 秦
TBTAKESHI BAMBA
TAKESHI BAMBA
The rapid development of next-generation sequencing techniques has enabled single-cell genomic and transcriptomic analyses, which have revealed the importance of heterogeneity in biological systems. However, analytical methods to accurately identify and quantify comprehensive metabolites from single mammalian cells with a typical diameter of 10–20 μm are still in development. The aim of this study was to develop a single-cell metabolomic analytical system based on highly sensitive nano-liquid chromatography tandem mass spectrometry (nano-LC/MS/MS) with multiple reaction monitoring. A packed nano-LC column (3-μm particle-size pentafluorophenylpropyl particles of dimensions 100 μm × 180 mm) was prepared using a slurry technique. The optimized nano-LC/MS/MS method showed 3–132-fold (averaged value, 26-fold) greater sensitivity than semimicro-LC/MS/MS, and the detection limits of several hydrophilic metabolites, including amino acids and nucleic acid related metabolites were in the sub-fmol range. By combining live single-cell sampling and nano-LC/MS/MS, we successfully detected 18 relatively abundant hydrophilic metabolites (16 amino acids and 2 nucleic acid related metabolites) from single HeLa cells (n = 22). Based on single-cell metabolic profiles, the 22 HeLa cells were classified into three distinct subclasses, suggesting differences in metabolic function in cultured HeLa cell populations. Our single-cell metabolomic analytical system represents a potentially useful tool for in-depth studies focused on cell metabolism and heterogeneity.

31 October 2019 in Metabolites
Verified
Journal Article
Open access
PDF file
YIYoshihiro Izumi
Yoshihiro Izumi
FMFumio Matsuda
Fumio Matsuda
Akiyoshi HirayamaAkiyoshi Hirayama
Akiyoshi Hirayama
KIKazutaka Ikeda
Kazutaka Ikeda
KYKita Yoshihiro
Kita Yoshihiro
Yoshiya OdaYoshiya Oda
Yoshiya Oda
Background: One of the current problems in the field of metabolomics is the difficulty in integrating data collected using different equipment at different facilities, because many metabolomic methods have been developed independently and are unique to each laboratory. Methods: In this study, we examined whether different analytical methods among 12 different laboratories provided comparable relative quantification data for certain metabolites. Identical samples extracted from two cell lines (HT-29 and AsPc-1) were distributed to each facility, and hydrophilic and hydrophobic metabolite analyses were performed using the daily routine protocols of each laboratory. Results: The results indicate that there was no difference in the relative quantitative data (HT-29/AsPc-1) for about half of the measured metabolites among the laboratories and assay methods. Data review also revealed that errors in relative quantification were derived from issues such as erroneous peak identification, insufficient peak separation, a difference in detection sensitivity, derivatization reactions, and extraction solvent interference. Conclusion: The results indicated that relative quantification data obtained at different facilities and at different times would be integrated and compared by using a reference materials shared for data normalization.

18 October 2024 in Nature Structural & Molecular Biology
Verified
Journal Article
Open access
PDF file
YMYugo Miyata
Yugo Miyata
KTKatsuya Takahashi
Katsuya Takahashi
YLYongchan Lee
Yongchan Lee
CSCheryl S. Sultan
Cheryl S. Sultan
RKRisa Kuribayashi
Risa Kuribayashi
KSKatsumori Segawa
Katsumori Segawa
Phospholipids are asymmetrically distributed in the plasma membrane (PM), with phosphatidylcholine and sphingomyelin abundant in the outer leaflet. However, the mechanisms by which their distribution is regulated remain unclear. Here, we show that transmembrane protein 63B (TMEM63B) functions as a membrane structure-responsive lipid scramblase localized at the PM and lysosomes, activating bidirectional lipid translocation upon changes in membrane curvature and thickness. TMEM63B contains two intracellular loops with palmitoylated cysteine residue clusters essential for its scrambling function. TMEM63B deficiency alters phosphatidylcholine and sphingomyelin distributions in the PM. Persons with heterozygous mutations in TMEM63B are known to develop neurodevelopmental disorders. We show that V44M, the most frequent substitution, confers constitutive scramblase activity on TMEM63B, disrupting PM phospholipid asymmetry. We determined the cryo-electron microscopy structures of TMEM63B in its open and closed conformations, uncovering a lipid translocation pathway formed in response to changes in the membrane environment. Together, our results identify TMEM63B as a membrane structure-responsive scramblase that controls PM lipid distribution and we reveal the molecular basis for lipid scrambling and its biological importance.

1 February 2022 in Metabolites
Verified
Journal Article
Open access
PDF file
SNShin Nishiumi
Shin Nishiumi
YIYoshihiro Izumi
Yoshihiro Izumi
Akiyoshi HirayamaAkiyoshi Hirayama
Akiyoshi Hirayama
MTMasatomo Takahashi
Masatomo Takahashi
MNMotonao Nakao
Motonao Nakao
TBTAKESHI BAMBA
TAKESHI BAMBA
In mass spectrometry-based metabolomics, the differences in the analytical results from different laboratories/machines are an issue to be considered because various types of machines are used in each laboratory. Moreover, the analytical methods are unique to each laboratory. It is important to understand the reality of inter-laboratory differences in metabolomics. Therefore, we have evaluated whether the differences in analytical methods, with the exception sample pretreatment and including metabolite extraction, are involved in the inter-laboratory differences or not. In this study, nine facilities are evaluated for inter-laboratory comparisons of metabolomic analysis. Identical dried samples prepared from human and mouse plasma are distributed to each laboratory, and the metabolites are measured without the pretreatment that is unique to each laboratory. In these measurements, hydrophilic and hydrophobic metabolites are analyzed using 11 and 7 analytical methods, respectively. The metabolomic data acquired at each laboratory are integrated, and the differences in the metabolomic data from the laboratories are evaluated. No substantial difference in the relative quantitative data (human/mouse) for a little less than 50% of the detected metabolites is observed, and the hydrophilic metabolites have fewer differences between the laboratories compared with hydrophobic metabolites. From evaluating selected quantitatively guaranteed metabolites, the proportion of metabolites without the inter-laboratory differences is observed to be slightly high. It is difficult to resolve the inter-laboratory differences in metabolomics because all laboratories cannot prepare the same analytical environments. However, the results from this study indicate that the inter-laboratory differences in metabolomic data are due to measurement and data analysis rather than sample preparation, which will facilitate the understanding of the problems in metabolomics studies involving multiple laboratories.

14 May 2025 in Communications Chemistry
Verified
Journal Article
Open access
YOYoichi Otsuka
Yoichi Otsuka
KKKazuya Kabayama
Kazuya Kabayama
AMAyane Miura
Ayane Miura
MTMasatomo Takahashi
Masatomo Takahashi
康秦康祐 秦
康祐 秦
MTMichisato Toyoda
Michisato Toyoda
The development of analytical technology that allows investigation of the diversity of cells that form biological tissues based on molecular information is important to elucidate the heterogeneity of cells and pathological mechanisms. Here, we present a proof-of-concept demonstration of single-cell mass spectrometry imaging (SC-MSI) via tapping-mode scanning probe electrospray ionization (t-SPESI), which is an atmospheric-pressure sampling ionization technique. We developed a novel t-SPESI unit that can be used in combination with an inverted fluorescence microscope and basic technologies to extract components from microregions of cells and measure ions with high sensitivity. We performed multimodal (fluorescence, lipid ion, and topographic) imaging of two types of HeLa cells labeled with fluorescent dyes and chemically fixed and showed the potential for subcellular-scale analysis of both cell structure and chemical composition. Furthermore, we evaluated the lipid species by comparing the SC-MSI results with those of supercritical fluid chromatography tandem mass spectrometry. The technical advancement presented here is effective for distinguishing cell types based on the signal intensity of lipid ions in single cells and investigating differences in the subcellular localization of lipids in different types of cells.

28 August 2022 in Metabolites
Verified
Journal Article
Open access
PDF file
YSYuki Soma
Yuki Soma
YIYoshihiro Izumi
Yoshihiro Izumi
TSTakehiko Shimohira
Takehiko Shimohira
MTMasatomo Takahashi
Masatomo Takahashi
YIYuri Imado
Yuri Imado
TBTAKESHI BAMBA
TAKESHI BAMBA
Pre-column fluorescent derivatization has been used for the fast quantification of amino acids using high-performance liquid chromatography (HPLC) systems. However, it generally requires an offline in-vial derivatization process with multiple derivatization reagents. The offline derivatization requires the same number of reaction vials as the number of sample vials for use as a reaction chamber for the derivatization reaction in an autosampler. Therefore, the number of samples analyzed per batch using the pre-column derivatization method is halved. To benefit from the pre-column derivatization method, we transformed the derivatization process from an offline chamber process to an online in-needle process (in-needle Pre-column Derivatization for Amino acids Quantification; iPDAQ). Fluorescent derivatization in the injection needle obviated the need for vacant vials as reaction chambers. Consequently, the throughput per batch improved up to two times, and the consumption of derivatization reagents was reduced to less than one-tenth of that in the conventional vial method. We demonstrated to separate and quantify the amino acids in various biological samples. Herein, we presented a novel HPLC-based amino acid quantification method that enables the continuous analysis of a large number of samples. The iPDAQ facilitates accurate amino acid quantification due to the automation of derivatization and achieves improvement in the throughput and reduction of analysis labor.