Li Zou

Dr. Li Zou

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2024 in Food Research International
Verified
Journal Article
Closed access
RHRuoying Huang
Ruoying Huang
MLMengyan Li
Mengyan Li
ZQZenglin Qu
Zenglin Qu
YLYang Liu
Yang Liu
XLXiaoxing Lu
Xiaoxing Lu
LZLi Zou
Li Zou


21 June 2022 in Food Research International
Verified
Journal Article
Closed access
LZLi Zou
Li Zou
MZManjun Zhang
Manjun Zhang
MLMengyan Li
Mengyan Li
ZXZhiyou Xiao
Zhiyou Xiao
LLLiansheng Ling
Liansheng Ling

24 February 2023 in Talanta
Verified
Journal Article
Closed access
MLMengyan Li
Mengyan Li
NLNian Luo
Nian Luo
XLXiaofei Liao
Xiaofei Liao
LZLi Zou
Li Zou

1 September 2021 in Analytica Chimica Acta
Verified
Journal Article
Closed access
LZLi Zou
Li Zou
CMChuoying Mai
Chuoying Mai
MLMengyan Li
Mengyan Li
YLYufen Lai
Yufen Lai

19 August 2021 in Molecules
Verified
Journal Article
Open access
PDF file
YLYufen Lai
Yufen Lai
LMLi Mengyan
Li Mengyan
XLXiaofei Liao
Xiaofei Liao
LZLi Zou
Li Zou
Abnormal levels of reduced glutathione (GSH) and glutathione reductase (GR) are usually related to a variety of diseases, so it is of great significance to determine the GSH concentration and GR activity. We herein develop a smartphone-assisted colorimetric biosensor for the detection of GSH and GR activity in human serum and mouse liver using hemin/G-quadruplex DNAzyme. Firstly, an obvious color change from colorless to green can be observed, owing to the high peroxidase-like activity of hemin/G-quadruplex DNAzyme toward 2,2′-azino-bis(3-ethylbenzothiozoline-6-sulfonic acid) (ABTS). With the addition of GSH or GR, the H2O2-mediated oxidation of ABTS catalyzed by hemin/G-quadruplex DNAzyme is significantly inhibited, resulting in remarkable color fading. Therefore, the detection of GSH and GR activity can be achieved by observing the color transition or measuring the absorbance at 420 nm. The detection limit was estimated to be as low as 0.1 μM and 10 μU/mL for GSH and GR, respectively. More interestingly, the RGB values of the sensing system can be identified by the smartphone application (APP, color collect), which makes it an ideal format for on-site determination and point-of-care testing (POCT). In addition, the proposed method shows excellent selectivity and acceptable applicability for the determination of GSH concentration and GR activity in human serum samples and mouse liver tissues, which might hold great application potential in clinical diagnosis and drug screening.