The behavior of different mooring line materials has a significant influence on the behavior of the mooring system and, consequently, the dynamic responses of the floating platform. Although there have been previous studies on FPSOs and their mooring systems, the influence of mooring line failure scenarios associated with different mooring materials has received less attention, particularly for turret-moored FPSOs with taut moorings. Thus, this paper investigates the behavior of different mooring line materials in intact, single-line, and double-line damaged conditions on the hydrodynamic responses of the FPSO, restoring behavior, mooring, and riser tensions considering wave conditions in the Gulf of Mexico. Mooring lines including Aramid, HMPE, polyester, and steel wire were considered in the middle segment, which was the segment of interest in this study. The restoring forces of the mooring system were found to increase with increasing mooring stiffness, and a higher stiffness resulted in a higher loss of restoring force in the case of single-line failure. In all cases, the submerged weight and material stiffness had a significant influence on dynamic responses, mooring tension, transient responses, riser tension, and especially on the ability of the mooring system to resist the case of single-line failure. Each material was observed to behave differently in each degree of freedom (DOF), showing the necessity to pay close attention to the selection of mooring material for specific objectives.
The Jacket platform needs gas and diesel to run its turbines, and in the end, they produce catastrophic emissions annually. The environmental concerns regarding these platforms have forced us to utilize an alternative source of energy that is sustainable and clean. In this study 51 locations, are of interest where oil and gas activities are in progress at present in the shape of a jacket platform or pipelines. The significant wave height and wave period scatter diagram data are collected from the platforms in the South China Sea. The linear wave theory is used to find the wave power. The given time period is converted into an equivalent time period first before wave energy is determined. The study shows that location no. 20 is the ideal location to deploy the wave energy converter Pelamis P2 with a potential mean wave power of 6.61 kW/m A single unit of Pelamis P2 can produce on an average electricity output of 91.37 kW/m including, the losses and machine efficiencies, whereas a wave farm can generate an average output of 62 GWh/yr. The electricity supply of 70.3 % of the minimum and 14.1 % of the maximum energy demand, while using only wave energy converter. If hybrid wind and wave energy system is used, then energy production will increase. The results show that the wave farm could also reduce the use of natural gas up to 17.6E06 m 3 /year, avoiding the emission of 12000 tonnes of CO and 54000 tonnes of NOx annually, and can save up to RM 20 billion annually with the reduction of natural gas emissions.
11 April 2018 in IOP Conference Series: Earth and Environmental Science
Four reinforced concrete rooms are used in this study, with varying floor areas, openings, and fuel loads. These rooms are office, Classroom, computer, and chemical laboratories of institutional buildings. The time versus Eurocode (EC) parametric fire relationship is determined and compared with ISO 834 and ASTM 119. The performance of the slab is evaluated based on the EC target reliability index of 3.8 for 50 years design period using the First Order Reliability Method (FORM). The probability of failure and structural reliability of each fire compartment at different fire duration is determined. Variables used were concrete compressive strength, a reduction factor of concrete compressive strength, steel yield strength, concrete cover, slab depth, unit width, and area of steel reinforcement provided. The reliability is determined at each 30 minutes fire duration for all fire compartments. The starting point is ambient temperature, then after every thirty minutes until the time when the maximum gas temperature is reached. The fire compartments were able to show fire resistance for two hours and then started to drop over time. Yield strength reduction factor, concrete cover, and area of reinforcement respectively were the most significant variables to determine the reliability index. The structure was able to withhold fire until two hours with a reliability of more than 3.8after that, the slab reliability was less than the target reliability and will need a repair.