Bryan Karney

Prof. Bryan Karney

Department of Civil & Mineral Engineering, University of Toronto, 35 St. George St., Toronto, ON M5S 1A4, Canada
orcid

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in Journal of Hydro-environment Research
Verified
Journal Article
Closed access
ACAndrew F. Colombo
Andrew F. Colombo
PLPedro Lee
Pedro Lee
Bryan KarneyBryan Karney
Bryan Karney

1 November 2002 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
ACAndrew F. Colombo
Andrew F. Colombo
Bryan KarneyBryan Karney
Bryan Karney
Leaky distribution systems are costly in terms of lost water, potentially adverse water quality effects, and the energy consumed in supplying the leaks. To characterize the energy effectiveness of a leaky segment in a single pipe, several dimensionless parameters are analytically derived, which relate the leak size and location to its associated energy burden and water loss. The computer program EPANET is used to simulate the energy costs of leaks on representative distribution networks. In particular, analysis is performed to illustrate the influence of total system demand, leak location, and topological complexity. Furthermore, the connection between water loss and energy costs illustrates the potential importance of energy costs when pipes are leaky. The impact of leaks on water age is also evaluated through simulation and via a dimensionless expression relating leak size and location to residence time.

1 August 2015 in Journal of Fluids and Structures
Verified
Journal Article
Closed access
SLShuaijun Li
Shuaijun Li
Bryan KarneyBryan Karney
Bryan Karney
GLGongmin Liu
Gongmin Liu

1 July 2000 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
Bruno BrunoneBruno Brunone
Bruno Brunone
Bryan KarneyBryan Karney
Bryan Karney
MMMichele Mecarelli
Michele Mecarelli
MFMarco Ferrante
Marco Ferrante
Transient conditions in closed conduits have traditionally been modeled as 1D flows with the implicit assumption that velocity profile and friction losses can be accurately predicted using equivalent 1D velocities. Although more complex fluid models have been suggested, there has been little direct experimental basis for selecting one model over another. This paper briefly reviews the significance of the 1D assumption and the historical approaches proposed for improving the numerical modeling of transient events. To address the critical need for better data, an experimental apparatus is described, and preliminary measurements of velocity profiles during two transient events caused by valve operation are presented. The velocity profiles recorded during these transient events clearly show regions of flow recirculation, flow reversal, and an increased intensity of fluid turbulence. The experimental pressures are compared to a water hammer model using a conventional quasi-steady representation of head loss an...


1 December 2007 in Journal of Infrastructure Systems
Verified
Journal Article
Closed access
ARAlina I. Racoviceanu
Alina I. Racoviceanu
Bryan KarneyBryan Karney
Bryan Karney
CKChristopher A. Kennedy
Christopher A. Kennedy
ACAndrew F. Colombo
Andrew F. Colombo
Given the rising concerns over scarce energy resources and global climate change, life-cycle inventories focusing on energy use and greenhouse gas (GHG) emissions were developed for the City of Toronto municipal water treatment system (WTS). Three processes within the facility use phase of the life cycle were considered: Chemical production, transportation of materials, and water treatment plant operation. The impacts of chemical manufacturing were estimated using the economic input-output life-cycle assessment model, while the inventories for transportation and operational environmental effects were based on data from the GHGenius model and regionally averaged data. Operational burdens, 60% of which are attributed to on-site pumping, accounted for 94% of total energy use and 90% of GHG emissions. By contrast, transportation-related energy use and emissions were deemed insignificant. The normalized energy use of the studied WTS was found to be between 2.3 and 2.5 MJ∕ m3 of water treated. Water conservatio...