Naiying Du

Dr. Naiying Du

Energy, Mining and Environment Research Center, National Research Council / Government of Canada, M-12, Rm 239,1200 Montreal Road, Ottawa, ON K1A 0R6, Canada

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in Macromolecules
Verified
Journal Article
Open access
MGMichael Guiver
Michael Guiver
MYMohamed Yahia
Mohamed Yahia
MDMauro M. Dal-Cin
Mauro M. Dal-Cin
GRGilles P. Robertson
Gilles P. Robertson
SGSadaf Saeedi Garakani
Sadaf Saeedi Garakani
NTNaser Tavajohi
Naser Tavajohi
We report a side group modification strategy to tailor the structure of a polymer of intrinsic microporosity (PIM-1). PIM-1 with an average of ∼50% of the repeat units converted to tetrazole is prepared, and a subsequent reaction then introduces three types of pseudo-ionic liquid tetrazole-like structures (PIM-1-ILx). The presence of pseudo-ionic liquid functional groups in the PIM-1 structure increases gas selectivities for O2/N2 and CO2/N2, while it decreases pure-gas permeabilities. The overall gas separation performance of PIM-1-ILx is close to the 2008 Robeson upper bound. Since the tetrazoles are versatile groups for building a wide variety of ionic liquids, the modification method can be expanded to explore a broad spectrum of functional groups.

24 January 2024 in Membranes
Verified
Journal Article
Open access
PDF file
PIPavlo Ignatusha
Pavlo Ignatusha
Haiqing LinHaiqing Lin
Haiqing Lin
NKNoé Kapuscinsky
Noé Kapuscinsky
LSLudmila Scoles
Ludmila Scoles
WMWeiguo Ma
Weiguo Ma
Naiying DuNaiying Du
Naiying Du
Direct air capture (DAC) is an emerging negative CO2 emission technology that aims to introduce a feasible method for CO2 capture from the atmosphere. Unlike carbon capture from point sources, which deals with flue gas at high CO2 concentrations, carbon capture directly from the atmosphere has proved difficult due to the low CO2 concentration in ambient air. Current DAC technologies mainly consider sorbent-based systems; however, membrane technology can be considered a promising DAC approach since it provides several advantages, e.g., lower energy and operational costs, less environmental footprint, and more potential for small-scale ubiquitous installations. Several recent advancements in validating the feasibility of highly permeable gas separation membrane fabrication and system design show that membrane-based direct air capture (m-DAC) could be a complementary approach to sorbent-based DAC, e.g., as part of a hybrid system design that incorporates other DAC technologies (e.g., solvent or sorbent-based DAC). In this article, the ongoing research and DAC application attempts via membrane separation have been reviewed. The reported membrane materials that could potentially be used for m-DAC are summarized. In addition, the future direction of m-DAC development is discussed, which could provide perspective and encourage new researchers’ further work in the field of m-DAC.

28 November 2022 in Membranes
Verified
Journal Article
Open access
PDF file
LLLin Li
Lin Li
BYBen Yu
Ben Yu
KDKrystal Davis
Krystal Davis
AKAaron King
Aaron King
MDMauro Dal-Cin
Mauro Dal-Cin
Naiying DuNaiying Du
Naiying Du
The increasing demand for neodymium (Nd) permanent magnets in electric motors has revived research interest of Nd recovery and separation from other rare earth elements (REEs). Typically, Nd/La separation is necessary for Nd recovery from primary ores and secondary resource recycling. This research used a flat sheet-supported liquid membrane (FSSLM) with different extractant-acid systems to extract Nd from a Nd/La mixture. The recovery and separation of Nd/La with 204P-H2SO4, 507P-HCl, and TBP-HNO3 were discussed. The results showed effective Nd recovery and promising Nd/La selectivity could be achieved in the 507P-HCl system, compared to 204P-H2SO4 and TBP-HNO3. The addition of citric acid to the feed solution was effective for pH buffering but did not improve the Nd transport or Nd/La selectivity. Long-term stability of the 507P-HCl extractant system was demonstrated by extending the processing time from 6 h to 6 days.