Junghoon Lee

Dr. Junghoon Lee


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2015 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
BSBiswajit Saha
Biswajit Saha
WTWei Quan Toh
Wei Quan Toh
Erjia LiuErjia Liu
Erjia Liu
STShu Beng Tor
Shu Beng Tor
DHDavid E Hardt
David E Hardt
JLJunghoon Lee
Junghoon Lee
Micro/nano hot-embossing and injection molding are two promising manufacturing processes for the mass production of workpieces bearing micro/nanoscale features. However, both the workpiece and micro/nano-mold are susceptive to structural damage due to high thermal stress, adhesion and friction, which occur at the interface between the workpiece and the mold during these processes. Hence, major constraints of micro/nano-molds are mainly attributed to improper replication and their inability to withstand a prolonged sliding surface contact because of high sidewall friction and/or high adhesion. Consequently, there is a need for proper surface coating as it can improve the surface properties of micro/nano-molds such as having a low friction coefficient, low adhesion and low wear rate. This review deals with the physical, mechanical and tribological properties of various surface coatings and their impact on the replication efficiency and lifetime of micro/nano-molds that are used in micro/nano hot-embossing and injection molding processes.

31 March 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DKDorsaf Kerfahi
Dorsaf Kerfahi
BTBinu M Tripathi
Binu M Tripathi
DSDharmesh Singh
Dharmesh Singh
HKHyoki Kim
Hyoki Kim
SLSujin Lee
Sujin Lee
JAJonathan M Adams
Jonathan M Adams
Carbon nanotubes (CNTs) are widely used in industry, but their environmental impacts on soil microbial communities are poorly known. In this paper, we compare the effect of both raw and acid treated or functionalized (fCNTs) multi-walled carbon nanotubes (MWCNTs) on soil bacterial communities, applying different concentrations of MWCNTs (0 µg/g, 50 µg/g, 500 µg/g and 5000 µg/g) to a soil microcosm system. Soil DNA was extracted at 0, 2 and 8 weeks and the V3 region of the 16S rRNA gene was PCR-amplified and sequenced using paired-end Illumina bar-coded sequencing. The results show that bacterial diversity was not affected by either type of MWCNT. However, overall soil bacterial community composition, as illustrated by NMDS, was affected only by fMWCNT at high concentrations. This effect, detectable at 2 weeks, remained equally strong by 8 weeks. In the case of fMWCNTs, overall changes in relative abundance of the dominant phyla were also found. The stronger effect of fMWCNTs could be explained by their intrinsically acidic nature, as the soil pH was lower at higher concentrations of fMWCNTs. Overall, this study suggests that fMWCNTs may at least temporarily alter microbial community composition on the timescale of at least weeks to months. It appears, by contrast, that raw MWCNTs do not affect soil microbial community composition.

4 February 2014 in Microbial Ecology
Verified
Journal Article
Closed access
PDF file
DKDorsaf Kerfahi
Dorsaf Kerfahi
JHJason Hall-Spencer
Jason Hall-Spencer
BTBinu M. Tripathi
Binu M. Tripathi
MMMarco Milazzo
Marco Milazzo
JLJunghoon Lee
Junghoon Lee
JAJonathan M. Adams
Jonathan M. Adams

16 April 2018 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
SBSangwoong Baek
Sangwoong Baek
EJEunyong Jeon
Eunyong Jeon
KPKyoung Sub Park
Kyoung Sub Park
KYKyung-Hwan Yeo
Kyung-Hwan Yeo
JLJunghoon Lee
Junghoon Lee
The measurement of xylem sap flow is essential to understanding plant physiology in agriculture. Advanced hydroponics, for instance, would require sap flow measurement to observe the plant reaction to environmental variables, such as sunlight, humidity, and soil water content. However, most conventional approaches for sap flow measurement have been limited to large woody plants. Plants grown in hydroponics, e.g., tomatoes and bell peppers, are smaller and softer, and can hardly survive the invasion of thick thermal probes for flow speed measurement. This report presents a microneedle thermal probe that can be implanted into a small plant for the measurement of sap flow through the xylem. A microscale single hot wire on a single probe is used to benefit from small-scale physics in a simple configuration. The single probe enables minimally invasive measurement with a small thermal impact on plant tissues. We show that the Granier method can be modified to use the single hot wire as a heater and a temperature sensor simultaneously. Tests with a tomato stem result in a universal calibration model that can be applied to the same species. We demonstrate routine measurements of sap flow in a greenhouse tomato tree over a month, opening up the possibility for production scale application. [2018-0006]

4 August 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
HJHanyung Jung
Hanyung Jung
CCChang Ve Cheah
Chang Ve Cheah
NJNamjo Jeong
Namjo Jeong
JLJunghoon Lee
Junghoon Lee
We report direct printing and photo-thermal reduction of graphite oxide (GO) to obtain a highly porous pattern of interdigitated electrodes, leading to a supercapacitor on a flexible substrate. Key parameters optimized include the amount of GO delivered, the suitable photo-thermal energy level for effective flash reduction, and the substrate properties for appropriate adhesion after reduction. Tests with supercapacitors based on the printed-reduced GO showed performance comparable with commercial supercapacitors: the energy densities were 1.06 and 0.87 mWh/cm3 in ionic and organic electrolytes, respectively. The versatility in the architecture and choice of substrate makes this material promising for smart power applications.

20 July 2017 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
EJEunyong Jeon
Eunyong Jeon
SCSeungyul Choi
Seungyul Choi
KYKyung-Hwan Yeo
Kyung-Hwan Yeo
KPKyoung Sub Park
Kyoung Sub Park
MRMitesh L Rathod
Mitesh L Rathod
JLJunghoon Lee
Junghoon Lee
Impedance measurement is a widely used technique for monitoring ion species in various applications. In plant cultivation, the impedance system is used to measure the electrical conductivity (EC) of nutrient solutions. Recent research has shown that the quality and quantity of horticultural crops, e.g. tomato, can be optimized by controlling the salinity of nutrient solutions. However, understanding the detailed response of a plant to a nutrient solution is not possible until the fruit is fully grown or by sacrificing the stem. To overcome this issue, horticultural crop cultivation requires real-time monitoring of the EC inside the stem. Using this data, the growth model of a plant could be constructed, and the response of the plant to external environment determined. In this paper, we propose an implantable microneedle device equipped with a micro-patterned impedance measurement system for direct measurement of the EC inside the tomato stem. The fabrication process includes silicon-based steps such as microscale deposition, photolithography, and a deep etching process. Further, microscale fabrication enables all functional elements to fulfill the area budget and be very accurate with minimal plant invasion. A two-electrode geometry is used to match the measurement condition of the tomato stem. Real-time measurement of local sap condition inside the plant in which real-time data for tomato sap EC is obtained after calibration at various concentrations of standard solution demonstrate the efficacy of the proposed device.