Thanh-Long Le

Prof. Thanh-Long Le

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2021 in Fluids
Verified
Journal Article
Open access
PDF file
TLThanh-Long Le
Thanh-Long Le
DHDuc-Thong Hong
Duc-Thong Hong
In this study, numerical computation is used to investigate the hydrodynamic characteristics of a torpedo-shaped underwater glider. The physical model of a torpedo-shaped underwater glider is developed by Myring profile equations and analyzed by the computational fluid dynamics approach. The Navier–Stokes equations and the energy equation coupled with the appropriate boundary conditions are solved numerically by using Comsol Multiphysics software. The numerical results contribute to the major part of reducing the effects of fluid flow on the glider’s profile and make the underwater glider more hydrodynamically efficient. The drag and lift forces acting on the underwater glider are enhanced by a higher velocity and a larger angle of attack of the underwater glider. Since the obtained results show a good observation with the experimental works, the need and the practicality of using CFD in the glider design process are proven.

8 September 2020 in Numerical Heat Transfer, Part A: Applications
Verified
Journal Article
Closed access
TLThanh-Long Le
Thanh-Long Le
JCJyh-Chen Chen
Jyh-Chen Chen
Bich Huy NguyenBich Huy Nguyen
Bich Huy Nguyen
The main objective of this paper is to numerically investigate the transient forward and backward thermocapillary motion of a water droplet in a microchannel occupied by the hexadecane oil. The top and bottom walls of the microchannel are kept at the ambient temperature. Two heat sources activated periodically are put on the front side and rear one of the droplet in a microchannel, respectively. When the heat source is activated, two vortices are formed inside a water droplet and the oil flow passes over the droplet in the microchannel. The forward and backward thermocapillary migration caused by two periodic heat sources results in the thermocapillary stress gradient along the fee interface which drives a water droplet to move to the cold side of the open channel. The mechanism of a droplet migration behavior is consistent with the previous experimental observation. The water droplet first accelerates rapidly, and then decelerates significantly at various intervals. The dynamic contact angle is significantly altered owing to the pressure change exerting on the hexadecane/water interface during the actuation process. The velocity of a water droplet is enlarged by a higher heating power and a larger microchannel height.

3 October 2022 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
TLThanh-Long Le
Thanh-Long Le
TNTan Tien Tien Nguyen
Tan Tien Tien Nguyen
TKTrung Tin Kieu
Trung Tin Kieu
Airborne infection isolation (AII) rooms are used to accommodate patients with highly infectious diseases and keep the released pathogens to limit the risk of cross-infection. This paper proposes a concept for an AII room made from two shipping containers to handle the scarcity of hospital beds when the COVID-19 disease spreads over the world. The proposed system consists of the main isolation room, anteroom, and toilet as well as other functional areas. In addition, the main isolation room was modeled with important components such as a supply air vent, exhaust air, a patient, and a bed. The computational fluid dynamics (CFD) approach based on the finite volume method (FVM) is used to solve the three-dimensional governing equations. The CO2 concentration was used to determine the infectious contaminant concentration of the air in the room. Therefore, the infectious control could be evaluated by the air change per hour (ACH). The numerical results show that the room temperature is maintained at 24°C, which is appropriate for people in the room. The laminar airflow extends downward to the floor after leaving the supply air vent on the ceiling, creating circulating patterns throughout the room. When evaluating the effectiveness of ventilation systems to remove airborne contaminants based on different ACH numbers, the CO2 concentration in the room was reduced to 581ppm, 477ppm, and 438ppm in the cases of 12 ACH, 24 ACH, and 48 ACH, respectively. As a result, the greater the number of air change per hour, the greater the performance for contaminant removal. It served as the foundation for assessing and optimizing the ventilation system of the portable negative pressure room.

20 January 2024 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
DTDuc Tran
Duc Tran
CLChih-Kuang Lin
Chih-Kuang Lin
PTPi-Cheng Tung
Pi-Cheng Tung
JHJeng-Rong Ho
Jeng-Rong Ho
TLThanh-Long Le
Thanh-Long Le

10 April 2025 in Results in Engineering
Verified
Journal Article
Open access
HVHoang-Phuong Vu
Hoang-Phuong Vu
TLThanh-Long Le
Thanh-Long Le
NNNhat-Anh Ngo
Nhat-Anh Ngo
TVThi-Hong-Nhi Vuong
Thi-Hong-Nhi Vuong
TTThien-Hau Tran
Thien-Hau Tran
QTQuang-Lam Tran
Quang-Lam Tran

13 May 2022 in Heat Transfer
Verified
Journal Article
Closed access
THThong Duc Hong
Thong Duc Hong
QNQuan Thien Phan Nghiem
Quan Thien Phan Nghiem
TLTam Thanh Le
Tam Thanh Le
TTTrung Minh Huu Tran
Trung Minh Huu Tran
TLThanh-Long Le
Thanh-Long Le