The effect of escape of X-ray fluorescence from scintillator elemental components on the detector energy resolution is investigated from a spectroscopic standpoint, for monolithic and pixelated crystals. Along with these, any other emissions in a given region of interest were also considered. In present spectral evaluations a range of ratios between the areas of the peaks (XRFesc) to (XRFesc + photoelectric) has been a priori set from 0-50%, according to literature indications, by 10% steps. At the upper extremes of these ratio values, maximum worsening in energy resolution values just below 40%, just above 10% and just below 10% have been estimated for the interest regions of Tc-99 and F-18e Cs-137, respectively. The inter-crystal XRF-escape is suggested to be considered among the effects producing image blurring in segmented scintillators due to the spread of events between neighbor pixels
A catalog of values of predicted energies of the K-XRF escape-peaks from compounds, used for radiation detectors, is presented for given incident gamma-rays suited for nuclear molecular medicine and low-energy spectrometry. The information relating to the compounds adds to that relating to the individual natural elements recently posted [RSC2025a]. The results of powerfunctions best-fit of XRF energy values vs. Z are listed in Table 1 for Kα2 orbital and Kedge. These expressions, allow simple calculations, avoiding the development of complex software. An extensive literature survey has been carried out mainly considering text-books, review articles and research reports. A final number compounds (Nc) equal to 729 has been obtained, whose distribution per number of constituting elements (Ne) is reported in Table 2. The predicted energy peaks are arranged in Tables 3 to 7 per Ne in the range from 2 to 8, showing the average value of 3.92 elements per compound. The catalog is conceived for nuclear molecular medicine and gamma-ray spectrometry where such peaks need to be recognized and their underlying area known in order to allow quantitative information.
The present paper introduces the so-called scintillators footprints, made of schemes showing XRF-escape peaks and their relative emission intensities in the energy range of interest for nuclear medicine SPECT and PET. A footprint describes the suitability of a scintillator for quantitative investigation with the best possible detectabilility. Sixteen scintillation materials have been identified in Literature, characterized by effective atomic number ranging between 22 to 75. The footprints of NaI:Tl and BGO, confirm the best suitability for quantitative spectral analisys at 140.5 keV and 511 keV, respectively. Moreover, for the low-Z eff scintillators like CaF 2 and CMSM, the XRF-escape effect is foresee irrelevant even at 140.5 keV, due to the small energy value of X-ray fluorescences.
The present work deals with a 10 × 10 array of (Lu0.7Y0.3)AP:Ce 2 × 2 × 10 mm3 pixels, manufactured by Crytur (Cz), that has been utilized in a previous paper. The crystal-array has been coupled to an 8 × 8 anodes H10966 model Hamamatsu (Jp) Position-Sensitive Photo Multiplier Tube (PSPMT) connected to electronics for single events scintillation read-out. The response of such a detector has been studied under Co-57, or Ba-133, or Cs-137 gamma-ray emissions, as well as with Lu-176 self-activity only. The present work is aimed at characterizing the individual crystal-pixels’ single-event responses in terms of pulse-height and of spreads of the 2-D charge-distributions. In particular, the charge-spread characterization pointed out several defects in the crystal-array assembly, not detected by usual pulse-height studies. The diagnostic method based on charge-spread analysis seems also well suited for scintillation array characterizations for gamma-ray detectors studies, as well as for quality controls of such pixelated devices during the lifetime of systems in the field of radionuclide medical imaging (SPECT and PET). The method is also appropriate for other applications where gamma-ray spectroscopy is required, like nuclear physics, astrophysics, astroparticle physics, homeland security, and non-proliferation.
The present paper introduces the so-called scintillator footprints, consisting of plots showing XRF-escape peaks and their relative emission intensities in the energy range of interest for nuclear medicine SPECT and PET. A footprint describes the suitability of a scintillator for quantitative investigation with the best possible detectability. Sixteen scintillation materials have been identified in the literature, characterized by effective atomic numbers Zeff ranging between 22 and 75. The footprints of NaI:Tl and BGO, confirm the best suitability for quantitative spectral analysis in SPECT and PET, at 140.5 keV and 511 keV, respectively. Moreover, for the low-Zeff scintillators like CaF2 and CMSM, the XRF-escape effect is to predict irrelevant even at 140.5 keV due to the small energy value of X-ray fluorescence.