Laura Jensen

Dr. Laura Jensen

Charité - Universitätsmedizin Berlin
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2021 in Tomography
Verified
Journal Article
Open access
PDF file
LJLaura Jensen
Laura Jensen
DKDamon Kim
Damon Kim
TEThomas Elgeti
Thomas Elgeti
ISIngo Steffen
Ingo Steffen
BHBernd Hamm
Bernd Hamm
SNSebastian Nagel
Sebastian Nagel
We aimed to evaluate radiomic features’ stability across different region of interest (ROI) sizes in CT and MR images. We chose a phantom with a homogenous internal structure so no differences for a feature extracted from ROIs of different sizes would be expected. For this, we scanned a plastic cup filled with sodium chloride solution ten times in CT and per MR sequence (T1-weighted-gradient-echo and T2-weighted-turbo-inversion-recovery-magnitude). We placed sphere-shaped ROIs of different diameters (4, 8, and 16 mm, and 4, 8, and 16 pixels) into the phantom’s center. Features were extracted using PyRadiomics. We assessed feature stability across ROI sizes with overall concordance correlation coefficients (OCCCs). Differences were tested for significance with the Mann–Whitney U-test. Of 93 features, 87 T1w-derived, 87 TIRM-derived, and 70 CT-derived features were significantly different between ROI sizes. Among MR-derived features, OCCCs showed excellent (>0.90) agreement for mean, median, and root mean squared for ROI sizes between 4 and 16 mm and pixels. We further observed excellent agreement for 10th and 90th percentile in T1w and 10th percentile in T2w TIRM images. There was no excellent agreement among the OCCCs of CT-derived features. In summary, many features indicated significant differences and only few showed excellent agreement across varying ROI sizes, although we examined a homogenous phantom. Since we considered a small phantom in an experimental setting, further studies to investigate this size effect would be necessary for a generalization. Nevertheless, we believe knowledge about this effect is crucial in interpreting radiomics studies, as features that supposedly discriminate disease entities may only indicate a systematic difference in ROI size.

17 September 2021 in Tomography
Verified
Journal Article
Open access
PDF file
DKDamon Kim
Damon Kim
LJLaura Jensen
Laura Jensen
TEThomas Elgeti
Thomas Elgeti
ISIngo Steffen
Ingo Steffen
BHBernd Hamm
Bernd Hamm
SNSebastian Nagel
Sebastian Nagel
Aim was to develop a user-friendly method for creating parametric maps that would provide a comprehensible visualization and allow immediate quantification of radiomics features. For this, a self-explanatory graphical user interface was designed, and for the proof of concept, maps were created for CT and MR images and features were compared to those from conventional extractions. Especially first-order features were concordant between maps and conventional extractions, some even across all examples. Potential clinical applications were tested on CT and MR images for the differentiation of pulmonary lesions. In these sample applications, maps of Skewness enhanced the differentiation of non-malignant lesions and non-small lung carcinoma manifestations on CT images and maps of Variance enhanced the differentiation of pulmonary lymphoma manifestations and fungal infiltrates on MR images. This new and simple method for creating parametric maps makes radiomics features visually perceivable, allows direct feature quantification by placing a region of interest, can improve the assessment of radiological images and, furthermore, can increase the use of radiomics in clinical routine.

15 September 2022 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
LJLaura Jensen
Laura Jensen
DKDamon Kim
Damon Kim
TEThomas Elgeti
Thomas Elgeti
ISIngo G. Steffen
Ingo G. Steffen
LSLars-Arne Schaafs
Lars-Arne Schaafs
SNSebastian N. Nagel
Sebastian N. Nagel
Background: In radiomics studies, differences in the volume of interest (VOI) are often inevitable and may confound the extracted features. We aimed to correct this confounding effect of VOI variability by applying parametric maps with a fixed voxel size. Methods: Ten scans of a cup filled with sodium chloride solution were scanned using a multislice computed tomography (CT) unit. Sphere-shaped VOIs with different diameters (4, 8, or 16 mm) were drawn centrally into the phantom. A total of 93 features were extracted conventionally from the original images using PyRadiomics. Using a self-designed and pretested software tool, parametric maps for the same 93 features with a fixed voxel size of 4 mm3 were created. To retrieve the feature values from the maps, VOIs were copied from the original images to preserve the position. Differences in feature quantities between the VOI sizes were tested with the Mann-Whitney U-test and agreement with overall concordance correlation coefficients (OCCC). Results: Fifty-five conventionally extracted features were significantly different between the VOI sizes, and none of the features showed excellent agreement in terms of OCCCs. When read from the parametric maps, only 8 features showed significant differences, and 3 features showed an excellent OCCC (≥ 0.85). The OCCCs for 89 features substantially increased using the parametric maps. Conclusions: This phantom study shows that converting CT images into parametric maps resolves the confounding effect of VOI variability and increases feature reproducibility across VOI sizes.

1 August 2023 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
LJLaura Jensen
Laura Jensen
FLFlorian N. Loch
Florian N. Loch
CKCarsten Kamphues
Carsten Kamphues
MSMehrgan Shahryari
Mehrgan Shahryari
SGStephan R. Marticorena Garcia
Stephan R. Marticorena Garcia
RRRolf Reiter
Rolf Reiter
Background: Although there is growing evidence that functional involvement and structural changes of mesenteric adipose tissue (MAT) influence the course of Crohn’s disease (CD), its viscoelastic properties remain elusive. Therefore, we aimed to investigate the viscoelastic properties of MAT in CD using magnetic resonance elastography (MRE), providing reference values for CD diagnosis. Methods: In this prospective proof-of-concept study, 31 subjects (CD: n=11; healthy controls: n=20) were consecutively enrolled in a specialized care center for inflammatory bowel diseases (tertiary/quaternary care). Inclusion criteria for the CD patients were a clinically and endoscopically established diagnosis of CD based on the clinical record, absence of other concurrent bowel diseases, scheduled surgery for the following day, and age of at least 18 years. Diagnoses were confirmed by histological analysis of the resected bowel the day after MRE. Subjects were investigated using MRE at 1.5-T with frequencies of 40–70 Hz. To retrieve shear wave speed (SWS), volumes of interest (VOIs) in MAT were drawn adjacent to CD lesions (MATCD) and on the opposite side without adjacent bowel lesions in patients (MATCD_Opp) and controls (MATCTRL). The presented study is not registered in the clinical trial platform. Results: A statistically significant decrease in mean SWS of 7% was found for MATCD_Oppvs. MATCTRL (0.76±0.05 vs. 0.82±0.04 m/s, P=0.012), whereas there was a nonsignificant trend with an 8% increase for MATCDvs. MATCD_Opp (0.82±0.07 vs. 0.76±0.05 m/s, P=0.098) and no difference for MATCD vs. MATCTRL. Preliminary area under the receiver operating characteristic curve (AUC) analysis showed diagnostic accuracy in detecting CD to be excellent for SWS of MATCD_Opp [AUC =0.82; 95% confidence interval (CI): 0.64–0.96] but poor for SWS of MATCD (AUC =0.52; 95% CI: 0.34–0.73). Conclusions: This study demonstrates the feasibility of MRE of MAT and presents preliminary reference values for CD patients and healthy controls. Our results motivate further studies for the biophysical characterization of MAT in inflammatory bowel disease.

3 December 2021 in Tomography
Verified
Journal Article
Open access
PDF file
LJLaura Jensen
Laura Jensen
DKDamon Kim
Damon Kim
TEThomas Elgeti
Thomas Elgeti
ISIngo Steffen
Ingo Steffen
BHBernd Hamm
Bernd Hamm
SNSebastian Nagel
Sebastian Nagel
We aimed to evaluate the stability of radiomic features in the liver of healthy individuals across different three-dimensional regions of interest (3D ROI) sizes in T1-weighted (T1w) and T2-weighted (T2w) images from different MR scanners. We retrospectively included 66 examinations of patients without known diseases or pathological imaging findings acquired on three MRI scanners (3 Tesla I: 25 patients, 3 Tesla II: 19 patients, 1.5 Tesla: 22 patients). 3D ROIs of different diameters (10, 20, 30 mm) were drawn on T1w GRE and T2w TSE images into the liver parenchyma (segment V–VIII). We extracted 93 radiomic features from the different ROIs and tested features for significant differences with the Mann–Whitney-U (MWU)-test. The MWU-test revealed significant differences for most second- and higher-order features, indicating a systematic difference dependent on the ROI size. The features mean, median, root mean squared (RMS), 10th percentile, and 90th percentile were not significantly different. We also assessed feature robustness to ROI size variation with overall concordance correlation coefficients (OCCCs). OCCCs across the different ROI-sizes for mean, median, and RMS were excellent (>0.90) in both sequences on all three scanners. These features, therefore, seem robust to ROI-size variation and suitable for radiomic studies of liver MRI.

1 November 2024 in Current Oncology
Verified
Journal Article
Open access
PDF file
LJLaura Jensen
Laura Jensen
DKDamon Kim
Damon Kim
TEThomas Elgeti
Thomas Elgeti
ISIngo Steffen
Ingo Steffen
LSLars-Arne Schaafs
Lars-Arne Schaafs
SNSebastian Nagel
Sebastian Nagel
Prostate Imaging Reporting and Data System version 2.1 (PI-RADS) category 3 lesions are a challenge in the clinical workflow. A better detection of the infrequently occurring clinically significant prostate cancer (csPCa) in PI-RADS 3 lesions is an important objective. The purpose of this study was to evaluate if feature maps calculated from T2-weighted (T2w) 3 Tesla (3T) MRI can help detect csPCa in PI-RADS category 3 lesions. In-house biparametric 3T prostate MRI examinations acquired between January 2019 and June 2023 because of elevated prostate-specific antigen (PSA) levels were retrospectively screened. Inclusion criteria were a PI-RADS 3 lesion and available results of an ultrasound-guided targeted and systematic biopsy. Exclusion criteria were a simultaneous PI-RADS category 4 or 5 lesion and hip replacement. Target lesions with the International Society of Urological Pathology (ISUP) grade group 1 were rated clinically insignificant PCa (ciPCa) and ≥2 csPCa. This resulted in 52 patients being included in the final analysis, of whom 11 (21.1%), 8 (15.4%), and 33 (63.5%) patients had csPCa, ciPCa, and no PCa, respectively, with the latter two groups being combined as non-csPCa. Eight of the csPCas were located in the peripheral zone (PZ) and three in the transition zone (TZ). In the non-csPCa group, 29 were located in the PZ and 12 in the TZ. Target lesions were marked with volumes of interest (VOIs) on axial T2w images. Axial T2w images were then converted to 93 feature maps. VOIs were copied into the maps, and feature quantity was retrieved directly. Features were tested for significant differences with the Mann–Whitney U-test. Univariate models for single feature performance and bivariate models implementing PSA density (PSAD) were calculated. Ten map-derived features differed significantly between the csPCa and non-csPCa groups (AUCs: 0.70–0.84). The diagnostic performance for TZ lesions (AUC: 0.83–1.00) was superior to PZ lesions (AUC: 0.74–0.85). In the bivariate models, performance in the PZ improved with AUCs >0.90 throughout. Parametric feature maps alone and as bivariate models with PSAD can (?) noninvasively identify csPCa in PI-RADS 3 lesions and could serve as a quantitative tool reducing ambiguity in PI-RADS 3 lesions.