This article presents the problems of powering wireless sensor networks operating in the structures of the Internet of Things (IoT). This issue was discussed on the example of a universal end node in IoT technology containing RFID (Radio Frequency Identification) tags. The basic methods of signal transmission in these types of networks are discussed and their impact on the basic requirements such as range, transmission speed, low energy consumption, and the maximum number of devices that can simultaneously operate in the network. The issue of low power consumption of devices used in IoT solutions is one of the main research objects. The analysis of possible communication protocols has shown that there is a possibility of effective optimization in this area. The wide range of power sources available on the market, used in nodes of wireless sensor networks, was compared. The alternative possibilities of powering the network nodes from Energy Harvesting (EH) generators are presented.
2 October 2013 in IEEE Instrumentation & Measurement Magazine
The advent of low cost microcontrollers and the development of DSP technology, intelligent data collection and processing, wireless communication, sharing of system resources, and self-identification has made distributed measurement systems extremely efficient, adaptive, and user friendly. These technologies and systems, however, require energy when operating in off-the-grid conditions, especially in environment monitoring. In such cases, a measurement subsystem of low energy consumption and a hybrid power station equipped with sources of renewable energy is the only reasonable solution.
22 March 2011 in IEEE Instrumentation & Measurement Magazine
There are many methods used for flow measurement. Among them, the electromagnetic method is unique because it is able to conduct measurements in open channels that carry polluted liquids with variable and axially asymmetric velocity profiles. This type of channel is encountered in sewage treatment plants and irrigation systems. The electromagnetic method of flow measurement is also used when the relationship between flow and liquid level is unknown. This paper concentrates on some aspects of designing an electromagnetic flow meter for an artificial channel with a rectangular cross-section a situation often encountered in wastewater treatment plants or irrigation systems.
8 October 2007 in IEEE Instrumentation & Measurement Magazine
This paper proposes a universal magnetic circuit for resolvers with different speed ratios. A resolver is an electromechanical transducer that converts the angular position of a rotor into an electric signal. The analysis and test results led to the conclusion that by using an appropriate magnetic material and assuring high-precision manufacturing it is possible to obtain high-precision resolvers with electrical error well below 1 minute of arc. Also it was proved that by using a single type of magnetic circuit it is possible to create multipole, two-speed resolvers. This system is used to improve both accuracy and resolution of angle measurement.
1 December 2005 in IEEE Instrumentation & Measurement Magazine
It would be great if the parts used in a traditional hip replacement lasted forever, but they don't. The surgery performed when the parts need to be repaired is called revision hip arthroplasty. The best method of revision is decided by one of three situations: injury, change in the joint components, or severe loss of bone stock. Orthopedic surgeons have observed that soon after revision surgery, when the patient is walking, the joint may become loose from displacement of the acetabulum, or it becomes too stiff or nonweight bearing. The implant may experience unsuccessful results because of rejection or poor rebuilding of tissues. There is an increasing number of unsuccessful operations, and the possible causes are being investigated in many research centers. The causes may be material defects, excessive wear of polyethylene elements, loosening of the artificial acetabulum, or wrong surgical techniques. Considering the significant cost of revision hip arthroplasty, long-lasting functionality of the prosthesis would lead to considerable savings.