Piotr Scislo

Dr. Piotr Scislo

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2016 in Cardiology Journal
Verified
Journal Article
Open access
KZKarol Zbroński
Karol Zbroński
ZHZenon Huczek
Zenon Huczek
DPDominika Puchta
Dominika Puchta
KPKatarzyna Paczwa
Katarzyna Paczwa
JKJanusz Kochman
Janusz Kochman
GOGrzegorz Opolski
Grzegorz Opolski
To compare 7 available risk models in the prediction of 30-day mortality following TAVI. Heart team decision supported by different risk score calculations is advisable to estimate the individual procedural risk before transcatheter aortic valve implantation (TAVI).One-hundred-and-fifty-six consecutive patients (n=156, 48% female, mean age 80.03 ± 8.18 years) who underwent TAVI between March 2010 and October 2014 were included in the study. Thirty-day follow-up was performed and available in each patient. Baseline risk was calculated according to EuroSCORE I, EuroSCORE II, STS, ACEF, Ambler's, OBSERVANT and SURTAVI scores.In receiver operating characteristics (ROC) analysis, neither of the investigated scales was able to distinguish between patients with or without an endpoint with areas under the curve (AUC) not exceeding 0.6, as follows: EuroScore I, AUC 0.55, 95% confidence intervals [CI] 0.47-0.63, P=0.59; EuroScore II, AUC 0.59 [0.51-0.67], P=0.23; STS, AUC 0.55 [0.47-0.63], P=0.52; ACEF, AUC 0.54 [0.46-0.62], P=0.69; Ambler's, AUC 0.54 [0.46-0.62], P=0.70; OBSERVANT, AUC 0.597 [0.52-0.67], P=0.21; SURTAVI, AUC 0.535 [0.45-0.62], P=0.65. SURTAVI model was calibrated best in high risk patients showing coherence between expected and observed mortality (10.8% vs. 9.4%. P=0.982). ACEF demonstrated best classification accuracy (17.5% vs. 6.9%, P=0.053, observed mortality in high vs. non-high risk cohort, respectively).None of investigated risk scales proved to be optimal in predicting 30-day mortality in unselected, real-life population with AS referred to TAVI. This data supports primary role of heart team in decision process of selecting patients for TAVI.

2 September 2019 in Clinical Research in Cardiology
Verified
Journal Article
Open access
PDF file
JKJanusz Kochman
Janusz Kochman
KZKarol Zbroński
Karol Zbroński
ŁKŁukasz Kołtowski
Łukasz Kołtowski
RPRadoslaw Parma
Radoslaw Parma
AOAndrzej Ochała
Andrzej Ochała
GOGrzegorz Opolski
Grzegorz Opolski
Background The aim of this study was to evaluate the outcomes of transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BiAV) stenosis using a mechanically expanded Lotus™ device. The prior experience with first-generation devices showed disappointing results mainly due to increased prevalence of aortic regurgitation (AR) that exceeded those observed in tricuspid stenosis. Methods and results We collected baseline, in-hospital, 30-day and 2-year follow-up data from a prospective, multicentre registry of patients with BiAV undergoing TAVI using Lotus™ valve. Safety and efficacy endpoints were assessed according to VARC-2 criteria. The study group comprised 24 patients. The mean age was 73.5 years and the mean EuroSCORE 2 was 4.35 ± 2.56%. MDCT analysis revealed Type 1 BiAV in 75% of patients. The mean gradient decreased from 60.1 ± 18.3 to 15 ± 6.4 mm Hg, the AVA increased from 0.6 ± 0.19 to 1.7 ± 0.21 cm2. One in-hospital death was observed secondary to aortic perforation. There was no severe AR and the rate of moderate AR equalled 9% at 30 days (n = 2). Device success was achieved in 83% and the 30-day safety endpoint was 17%. In the 2-year follow-up, the overall mortality was 12.5% and the 2-year composite clinical efficacy endpoint was met in 25% of the patients (n = 6) Conclusions The TAVI in selected BiAV patients using the Lotus™ is feasible and characterized by encouraging valve performance and mid-term clinical outcomes. Graphic abstract

1 January 2009
Verified
Journal Article
Closed access
DKDariusz A Kosior
Dariusz A Kosior
JKJanusz Kochanowski
Janusz Kochanowski
PSPiotr Scislo
Piotr Scislo
RPRadosław Piatkowski
Radosław Piatkowski
MPMarek Postula
Marek Postula
GOGrzegorz Opolski
Grzegorz Opolski

1 January 2018 in Archives of Medical Science
Verified
Journal Article
Open access
PSPiotr Scislo
Piotr Scislo
JKJanusz Kochanowski
Janusz Kochanowski
ŁKŁukasz Kołtowski
Łukasz Kołtowski
GOGrzegorz Opolski
Grzegorz Opolski
Introduction: The aim of the study was to determine the utility and safety of three-dimensional contrast low-dose dobutamine echocardiography (3DCLDDE) in the evaluation of myocardial viability early after ST-elevation myocardial infarction (STEMI). Material and methods: We prospectively...

28 March 2021 in Echocardiography
Verified
Journal Article
Closed access
PDF file
PSPiotr Scislo
Piotr Scislo
RPRadosław Piątkowski
Radosław Piątkowski
MBMonika Budnik
Monika Budnik
JKJanusz Kochanowski
Janusz Kochanowski

22 April 2019 in Echocardiography
Verified
Journal Article
Closed access
PDF file
PSPiotr Scislo
Piotr Scislo
KGKajetan Grodecki
Kajetan Grodecki
RWRadosław Wilimski
Radosław Wilimski
BRBartosz Rymuza
Bartosz Rymuza
JKJanusz Kochman
Janusz Kochman
ZHZenon Huczek
Zenon Huczek