This work presents the simulation of a steam generator or water-tube boiler through the implementation in MATLAB® for a proposed mathematical model. Mass and energy balances for the three main components of the boiler—the drum, the riser and down-comer tubes—are presented. Three alternative solutions to the ordinary differential equation (ODE) were studied, based on Runge–Kutta 4th order method, Heun’s method, and MATLAB function Ode45. The best results were obtained using MATLAB® function Ode45 based on the Runge–Kutta 4th Order Method. The error was less than 5% for the simulation of the steam pressure in the drum, the total volume of water in the boiler, and the mixture quality in relation to what was reported.
This paper summarizes a bibliographic review of the main articles published in recent years in the power cycles area, with special emphasis on working fluid mixtures. Likewise, the most relevant theoretical fundaments for performing the mathematical modeling of this class of working fluids and, therefore, obtaining their thermodynamic properties, as well as the experimental methods used in the characterization of the phase equilibrium that allow obtaining the adjustment parameters are covered in this article.
1 October 2019 in Journal of Physics: Conference Series
The formulation of a mathematical model that allows simulating the operation of chemisorption refrigeration systems that use medium and low temperature thermal sources such as waste heat and have the purpose of increasing the energy efficiency of industrial and/or residential applications, is a prerequisite to design and facilitate the use of these systems. Such model is described here and is intended to evaluate the heat transfer inside of chemisorption reactor for refrigeration system that can operate with a metallic salt (sorbent) mixed with expanded graphite and NH3 as refrigerant fluid (adsorbate). The effectiveness of the model is validated through experimental results obtained for a SrCl2/NH3 pair allowing to postulate, a kinetic and thermal model that can be adapted to sorbent/adsorbate pairs of the same type operating under various conditions and thus quantify how operational variables affect the performance parameters of these systems. To this end, the impact of the cycle time and reactor radius on the specific cooling power (SCP) and the coefficient of performance (COP) is measured, concluding that these operational variables exert effects of an opposite nature on the SCP and COP of the system.
1 December 2020 in Journal of Physics: Conference Series
In the research work, an isokinetic sampling of the evaluation of pollutant emissions to the atmosphere generated by a Hoffman continuous kiln was carried out in samples with two dosages, one composed of 100% clay and the other with 70% clay and 30% calcium carbonate. The methods for the evaluation of pollutant emissions in stationary sources were used and 3 runs were performed, and in each run 4 measurements were made every 15 minutes. The results in the emissions of the firing using calcium carbonate with respect to the samples composed of 100% clay reduced the discharges to the atmosphere by 7.30% in particulate matter, 20.18% in nitrogen oxides, 21.65% in sulfur dioxide, and 15.35% and 8.89% in hydrochloric and hydrofluoric acid respectively. The concentration of particulate material emitted to the environment in the two firing processes does not meet the permissible emission standard of less than 250 mg/mm3, while the other pollutants comply with Colombian environmental regulations. The use of fluxes for the manufacture of bricks reduced the concentrations of gases emitted into the environment decreasing possible health effects such as acute respiratory disease, eye irritation, and aggravation of heart disease.
1 November 2020 in Journal of Physics: Conference Series
Chemisorption cooling is a type of technology that facilitates energy saving and produces less environment impact than that produced by vapor compression cooling systems. The advantages or disadvantages of these systems can be explored from mathematical models through which the impact of different working pairs as well as construction and operating parameters on these cooling systems can be described. In this sense, the impact of design variables on performance coefficient of a chemisorption refrigeration system that uses sodium bromide and ammonia as working pairs are evaluated from a mathematical model that describes the heat transfer into the system. The results indicate that the cycle time affects favorably the coefficient of performance as well as the apparent specific density of the sorbent and the reactor radius. Although the coefficient of performance values is low when compared to vapor compression cooling systems, the system can be operated by low temperature thermal sources, found in thermal solar collectors or flue gases, and it can increase the energy efficiency of industrial or residential applications.