ANDRE GONCALVES Prospero

Dr. ANDRE GONCALVES Prospero


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2017 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
CQCaio C. Quini
Caio C. Quini
ABAndris Bakuzis
Andris Bakuzis
PFPatrícia Fidelis-De-Oliveira
Patrícia Fidelis-De-Oliveira
GMGustavo M. Moretto
Gustavo M. Moretto
JMjose Ricardo Arruda Miranda
jose Ricardo Arruda Miranda
We introduce and demonstrate that the AC biosusceptometry (ACB) technique enables real-time monitoring of magnetic nanoparticles (MNPs) in the bloodstream. We present an ACB system as a simple, portable, versatile, non-invasive, and accessible tool to study pharmacokinetic parameters of MNPs, such as circulation time, in real time. We synthesized and monitored manganese doped iron oxide nanoparticles in the bloodstream of Wistar rats using two different injection protocols. Aiming towards a translational approach, we also simultaneously evaluated cardiovascular parameters, including mean arterial pressure, heart rate, and episodes of arrhythmia in order to secure the well-being of all animals. We found that serial injections increased the circulation time compared with single injections. Immediately after each injection, we observed a transitory drop in arterial pressure, a small drop in heart rate, and no episodes of arrhythmia. Although some cardiovascular effects were observed, they were transitory and easily recovered in both protocols. These results indicate that the ACB system may be a valuable tool for in vivo, real-time MNP monitoring that allows associations with other techniques, such as pulsatile arterial pressure and electrocardiogram recordings, helping ensuring the protocol safety, which is a fundamental step towards clinical applications.

1 May 2017 in Nanomedicine: Nanotechnology, Biology and Medicine
Verified
Journal Article
Closed access
CQCaio C. Quini
Caio C. Quini
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
MCMarcos F.F. Calabresi
Marcos F.F. Calabresi
GMGustavo M. Moretto
Gustavo M. Moretto
NZNicholas Zufelato
Nicholas Zufelato
JMJose R.A. Miranda
Jose R.A. Miranda

14 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
GSGuilherme Soares
Guilherme Soares
JFJoão V. C. Faria
João V. C. Faria
LPLeonardo A. Pinto
Leonardo A. Pinto
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
GPGabriele M. Pereira
Gabriele M. Pereira
JMjose Ricardo Arruda Miranda
jose Ricardo Arruda Miranda
Once administered in an organism, the physiological parameters of magnetic nanoparticles (MNPs) must be addressed, as well as their possible interactions and retention and elimination profiles. Alternating current biosusceptometry (ACB) is a biomagnetic detection system used to detect and quantify MNPs. The aims of this study were to evaluate the biodistribution and clearance of MNPs profiles through long-time in vivo analysis and determine the elimination time carried out by the association between the ACB system and MnFe2O4 nanoparticles. The liver, lung, spleen, kidneys, and heart and a blood sample were collected for biodistribution analysis and, for elimination analysis, and over 60 days. During the period analyzed, the animal’s feces were also collectedd. It was possible to notice a higher uptake by the liver and the spleen due to their characteristics of retention and uptake. In 60 days, we observed an absence of MNPs in the spleen and a significant decay in the liver. We also determined the MNPs’ half-life through the liver and the spleen elimination. The data indicated a concentration decay profile over the 60 days, which suggests that, in addition to elimination via feces, there is an endogenous mechanism of metabolization or possible agglomeration of MNPs, resulting in loss of ACB signal intensity.

24 January 2020 in Molecular Pharmaceutics
Verified
Journal Article
Closed access
ASAilton A. Sousa-Junior
Ailton A. Sousa-Junior
SMSebastião Mendanha
Sebastião Mendanha
MCMarcus S. Carrião
Marcus S. Carrião
GCGustavo Capistrano
Gustavo Capistrano
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
ABAndris Bakuzis
Andris Bakuzis

1 March 2018 in Anais da Academia Brasileira de Ciências
Verified
Journal Article
Open access
PDF file
SCSabrina G. Cherelli
Sabrina G. Cherelli
MSMaria Márcia èreira Sartori
Maria Márcia èreira Sartori
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
ABAdriano W. Ballarin
Adriano W. Ballarin
This study evaluated the quality of heartwood and sapwood from mature trees of three species of Eucalyptus, by means of the qualification of their proportion, determination of basic and apparent density using non-destructive attenuation of gamma radiation technique and calculation of the density uniformity index. Six trees of each species (Eucalyptus grandis - 18 years old, Eucalyptus tereticornis - 35 years old and Corymbia citriodora - 28 years old) were used in the experimental program. The heartwood and sapwood were delimited by macroscopic analysis and the calculation of areas and percentage of heartwood and sapwood were performed using digital image. The uniformity index was calculated following methodology which numerically quantifies the dispersion of punctual density values of the wood around the mean density along the radius. The percentage of the heartwood was higher than the sapwood in all species studied. The density results showed no statistical difference between heartwood and sapwood. Differently from the density results, in all species studied there was statistical differences between uniformity indexes for heartwood and sapwood regions, making justifiable the inclusion of the density uniformity index as a quality parameter for Eucalyptus wood.

1 April 2019 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
OBOswaldo Baffa
Oswaldo Baffa
RMR.H. Matsuda
R.H. Matsuda
SAS. Arsalani
S. Arsalani
APANDRE GONCALVES Prospero
ANDRE GONCALVES Prospero
JMJ.R.A. Miranda
J.R.A. Miranda
RWR.T. Wakai
R.T. Wakai