Anna Vaskuri

Dr. Anna Vaskuri

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2023 in Superconductor Science and Technology
Verified
Journal Article
Open access
RJRóbert Jurčo
Róbert Jurčo
AVAnna Vaskuri
Anna Vaskuri
BCBenoit CURE
Benoit CURE
ADAlexey Dudarev
Alexey Dudarev
MMMatthias Mentink
Matthias Mentink
We have developed a high-temperature superconducting (HTS) flux pump using high-power metal-oxide-semiconductor field-effect transistors (MOSFETs) for switching. For its primary coil, two commercial transformers are utilized, each consisting of two copper coils wound on a single iron core, which enables changing the load current over primary current ratio (101 or 194) between the primary and secondary coils. Full-wave rectification is achieved with two half-wave secondary circuits, each of them having six HTS one-turn coils to lower the resistance. Each secondary coil is composed out of nickel-reinforced BSCCO tapes, where 12 MOSFETs have been soldered in parallel straight to the tapes and controlled with analog electronics. Secondary coils are clamped to custom-made copper-stabilized HTS current leads. A support structure for keeping the HTS coils in place was 3D-printed using cryogenic-compatible composite material PETG-CF20. Resistances of the two secondary circuits were measured to be 4 μ Ω and 7 μ Ω at 77 K with a total critical current of 980 A. We successfully ramped up a 50 µH Conductor on Round Core solenoid at 77 K using our HTS flux pump with 50 Hz AC voltage source. We achieved a maximal load current of 900 A and exceeded the 715 A critical current of the solenoid. During the thermal runaway of the magnet, the increased load voltage limits the maximum load current supplied by the flux pump.

1 July 2021 in Optics Express
Verified
Journal Article
Open access
PDF file
AVAnna Vaskuri
Anna Vaskuri
MSMichelle S. Stephens
Michelle S. Stephens
NTNathan A. Tomlin
Nathan A. Tomlin
MSMatthew T. Spidell
Matthew T. Spidell
CYChristopher S. Yung
Christopher S. Yung
JLJohn H. Lehman
John H. Lehman
We have developed a planar absolute radiometer for room temperature (PARRoT) that will replace the legacy C-series calorimeter as the free-space continuous-wave laser power detector standard at the National Institute of Standards and Technology (NIST). This instrument will lower the combined relative expanded measurement uncertainty (k = 2) from 0.84 % to 0.13 %. PARRoT’s performance was validated by comparing its response against a transfer standard silicon trap detector traceable to NIST’s primary standard laser optimized cryogenic radiometer (LOCR) and against the C-series calorimeter. On average, these comparisons agreed to better than 0.008 % and 0.05 %, respectively.

9 February 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
NDN. Deelen
N. Deelen
BCBenoit CURE
Benoit CURE
ADA. Dudarev
A. Dudarev
MMM. Mentink
M. Mentink
AVAnna Vaskuri
Anna Vaskuri
Particle physics experiments make use of magnetic fields up to $4 \,\mathrm{T}$ to bend electrically charged particles such that their charge and momentum can be determined. The particle energy measurement requires a low amount of material, or material that is highly transparent to particles inside the calorimeter volume. The conflict between the small volume of space reserved for a magnet and having a field of several teslas inside the detector is often resolved by using superconducting magnets. Up to now, large particle physics detector magnets have been constructed with low temperature superconductors, but there are clear benefits from using high temperature superconductors in future particle physics detector designs, such as allowing for an elevated operating temperature and the reduced amount of superconductor needed. In addition to the HTS material itself, additional material is needed to support the Lorentz forces, and to temporarily carry the current in case of a quench since these magnets are always one-of-a-kind and they need to operate reliably and without damage in case of a failure scenario. The stabilizer has to be a low-density material for high particle transparency, such as aluminium. Since the density of the superconductor is a factor of 4 higher than the density of aluminium, a reduction of superconducting material also means an improvement of the particle transparency: the density of a material is directly related to its particle transparency. This paper presents a conceptual design for high temperature superconducting detector magnets and a study of the type of aluminium stabilizer used.

28 October 2021 in Optica
Verified
Journal Article
Closed access
AVAnna Vaskuri
Anna Vaskuri
DRDaniel W. Rahn
Daniel W. Rahn
PWPaul A. Williams
Paul A. Williams
JLJohn H. Lehman
John H. Lehman
We have developed an absolute radiometer to measure laser power by means of radiation pressure in a closed control-loop configuration using diamagnetically levitated pyrolytic graphite as the soft spring and gravity as a contactless restoring force. Our approach takes advantage of an extremely low spring stiffness (2.95 mN/m) afforded by diamagnetic levitation above a permanent magnet array and a lock-in amplifier in the feedback loop to attain a 30 m W r m s noise. A horizontally directed laser beam impinges on a highly reflective dielectric stack mirror mounted on the levitating pyrolytic graphite shuttle. The light’s momentum displaces the shuttle, and its position is restored by tilting the magnet array with a piezoelectric actuator. The closed-loop configuration avoids the need for accurate knowledge of the system spring stiffness or environmental dependencies of the diamagnetic levitation. Absolute laser power measured is traceable to the mass of the diamagnetically levitating shuttle system, the local gravitational acceleration, and the interferometrically measured tilt angle of the magnet array. The system is demonstrated with a laser power of 2.7 W, yielding a combined relative expanded uncertainty ( k = 2 ) of 1.9%. The upper limit of measurable power is determined by the range of the piezoelectric actuator, and the minimum power is currently limited by the noise floor that is constrained by air currents.

29 March 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AVAnna Vaskuri
Anna Vaskuri
BCBenoit CURE
Benoit CURE
ADAlexey Dudarev
Alexey Dudarev
MMMatthias Mentink
Matthias Mentink
Within the context of EP R&D, CERN is developing a high-temperature superconducting (HTS) conductor for future superconducting detector magnet projects. The conductor features a Rare-Earth Barium Copper Oxide (REBCO) tapes soldered to a copper-coated high-purity aluminium stabilizer. Critical currents of the 200 mm long straight cable samples measured with various numbers of REBCO tapes at 77 K are consistent with empirical scaling formulas for critical current within 10%. A few percent deviations are expected to arise from the critical current variation along the length of the HTS tape. No degradation was observed after multiple soldering and de-soldering cycles at 165 $^\mathrm{o}$ C with Bi–Sn based solder and after thermal cycling between 77 K and room temperature. However, extreme bending (of 100 mm radius) of the already soldered HTS cable leads to failure of the cable. We repeated the critical current measurements with a 650 mm long cable loop sample with 85 mm bending radius, where the HTS tapes were soldered after the aluminium profile was bent. The critical current of the HTS cable loop was 7% lower than the prediction. Based on the first critical current measurements, the HTS cable preparation method presented in this work results in repeatable quality aluminium-stabilized HTS cable.

14 September 2023 in Metrologia
Verified
Journal Article
Open access
MKMikhail Korpusenko
Mikhail Korpusenko
AVAnna Vaskuri
Anna Vaskuri
FMFarshid Manoocheri
Farshid Manoocheri
EIErkki Ikonen
Erkki Ikonen
We determine experimentally the internal quantum efficiency of a 3-element trap detector made of Hamamatsu S1337 photodiodes and of a predictable quantum efficient detector (PQED) over the wavelength range of 250–500 nm using an electrically calibrated pyroelectric radiometer as reference detector. The PQED is made of specially designed induced junction photodiodes, whose charge-carrier recombination losses are minimized. The determined internal quantum efficiency of PQED is always 1 or larger, whereas the 3-element trap detector has internal quantum efficiency smaller than 1 in the spectral range of 330–450 nm. This finding demonstrates the advantages of PQED photodiodes for studying the quantum yield due to impact ionization by charge carriers in the silicon lattice. For this purpose, we develop an extrapolation model for the charge-carrier recombination losses of the PQED, which allows us to separate the quantum yield from the measured internal quantum efficiency. Measurements of PQED spectral responsivity thus allow to determine the quantum yield in silicon, which can be further used for quantifying the charge-carrier recombination losses in the 3-element trap detector. Numerical values of the latter are from 6% to 2% in the spectral range from 250 nm to 380 nm. Finally, our results are encouraging for the aim of developing the PQED to a primary detector standard also at ultraviolet wavelengths.