Conventional vector current control scheme has been widely used in grid-connected inverter systems. However, it suffers from severe power limitation issues under weak grids. This article reveals that the coupling effect between the power delivery and the voltage at the point of common coupling causes the static power limit, which only depends on physical parameters of the system. When the stability of the control scheme is considered, negative resistance characteristics of the phase-locked loop (PLL) mainly result in the small-signal stability limit, which is called the dynamic power limit in this article. Because the small-signal stability limit can be improved by using different control methods, it attracts lots of research attention. In this article, a simplified d – q small-signal impedance model is introduced to show the destabilizing factors. Then, an initial small-signal impedance reshaping method is proposed to counteract the major destabilizing factor caused by the PLL. Based on the initial impedance reshaping method, an improved control scheme is proposed. Through exhaustive mathematical analysis, it is proved that the dynamic power limit can be extended almost to the static power limit by using this proposed method. Finally, simulation and experimental results verify the effectiveness of the proposed method.
24 August 2022 in IEEE Transactions on Industrial Electronics
As the capacity of renewable energy generation increases, grid-forming (GFM) inverters are deemed as promising solutions for low inertia power grids. However, power-electronic-based inverters have limited overcurrent capability, so additional overcurrent protection schemes are necessary. More importantly, the stability should not be jeopardized by using additional overcurrent protection schemes. However, GFM inverters with the conventional current reference limiting method tend to be unstable under large grid disturbances such as grid frequency drop. To address this problem, this article proposes a virtual power angle limiting method. The main idea of this method is to limit the output power by limiting the power angle instead of directly limiting the current reference. Thus, the power synchronization control law is still satisfied when the overcurrent protection is triggered, so that the stability can be maintained. Besides, after redesigning the power angle limiting value, the proposed method is also suitable for grid voltage sag cases. A significant advantage of the proposed method is that the output current can be limited automatically during grid voltage sag or frequency drop events without the need of fault detection or tuning control structures and parameters. Simulation and experimental results have verified the effectiveness of the proposed method.
Conventional dual-loop grid-forming (GFM) inverters tend to be unstable when connecting to a stronger grid with a small grid inductance. Virtual inductance methods can increase the equivalent inductance to enhance stability. However, the impact of virtual inductance on the small-signal stability of GFM inverters is still absent in existing research. Hence, the stabilities of two virtual inductance methods (i.e. admittance method and impedance method) are compared initially in this paper. It is revealed that the stability range of the virtual admittance method is wider than that of the virtual impedance method. Besides, for the virtual admittance method, the stability is mainly influenced by the value of virtual admittance. A complex-value single-input single-output (SISO) small-signal model is proposed in this paper to find the critical stable value of the virtual admittance, which is not only simple but almost as accurate as the multiple-input multiple-output (MIMO) model. Finally, simulation results verify the effectiveness of theoretical analysis.
As the capacity of wind power generation increases, grid-forming (GFM) wind turbine generators are deemed as promising solutions to support the system frequency for future low inertia power grids. So far, the GFM converter with a nearly ideal dc voltage source has been studied thoroughly. However, when the GFM converter is applied to wind power applications, there are some realistic problems and challenges, such as coordinating wind turbine control and GFM control, limited energy to support the grid, variable wind speed, etc. These problems still need more discussion. In this paper, an overview of challenges and potential solutions of GFM converters applied to wind power generation systems are provided, where different energy reserving schemes, GFM control schemes, and overcurrent protection schemes are compared and discussed. Finally, a few perspectives on future trends are shared according to the authors’ knowledge.
Continuously expanding deployments of distributed power generation systems are transforming conventional centralized power grids into mixed distributed electrical networks. The higher penetration and longer distance from the renewable energy source to the main power grid result in lower grid strength, which stimulates the power limitation problem. Aimed at this problem, case studies of inductive and resistive grid impedance with different grid strengths have been carried out to evaluate the maximum power transfer capability of grid-connected inverters. It is revealed that power grids with a higher short circuit ratio (SCR) or lower resistance-inductance ratio (R/X) provide higher power transfer capability. Moreover, under the resistive grid conditions, a higher voltage at the point of common coupling (PCC) is beneficial to increase the power transfer capability. Based on mathematical analysis, the maximum power curves in the inductive and resistive grids can be found. Moreover, a performance index is proposed in this paper to quantify the performance of the system with different parameter values. Finally, the effectiveness of the analysis is verified by simulation.
26 March 2024 in Nature Reviews Electrical Engineering