Petr Drexler

Dr. Petr Drexler

Department of Theoretical and Experimental Electrical Engineering, Brno University of Technology, 616 00 Brno, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PDPetr Drexler
Petr Drexler
MČMartin Čáp
Martin Čáp
Pavel FialaPavel Fiala
Pavel Fiala
MSMiloslav Steinbauer
Miloslav Steinbauer
RKRadim Kadlec
Radim Kadlec
LKLubomír Kočiš
Lubomír Kočiš
The paper reports on the solution, principles, and application results related to a system for diagnosing main transformers in power plants via the radiofrequency method. The subject of the diagnostics is the occurrence of partial discharge activity in transformers. The technical solution of the system is characterized in the introductory section of the article. There then follows a description of the operating principle and the implemented novel advanced methods for signal detection and source localization. The results obtained from practical application of the system within the diagnostics of high-power transformers are presented as well. Because ambient electromagnetic disturbance was recognized as a major issue during the system development, novel detection methods were proposed, implemented, and verified. The principal approach utilizes an external radiofrequency sensor to detect outer impulse disturbance and to eliminate disturbance-triggered acquisitions, and it also ensures direct real-time visualization of the desired impulse signals. The ability of weak signal detection was verified via artificial impulse signal injection into the transformer. The developed detection methods were completed with localization techniques for signal source estimation. The desired impulse signal was detected and localized during full operation of the main transformer, despite the presence of strong electromagnetic interference.

30 April 2007 in IEEE Sensors Journal
Verified
Journal Article
Open access
PDPetr Drexler
Petr Drexler
Pavel FialaPavel Fiala
Pavel Fiala
There are some suitable methods for the measurement of ultrashort solitary electromagnetic pulses (EMP) that are generated by high-power microwave generators. The characteristics of EMPs are high-power level (Pmax = 250 MW) and very short-time duration (tp euro (1, 60) ns). Special requirements for measurement methods have to be considered because of the specific EMPs properties. In this paper, two suitable methods for this application are presented. The first one, the calorimetric method, utilizes the thermal impacts of microwave absorption. The second method presented-the magnetooptic (MO) method-uses the Faraday's MO effect as a sensor principle. A combined calorimetric sensor was realized and there were some experimental EMP measurements made with good results. The sensor utilizing the MO method is still in development.

10 December 2016 in Entropy
Verified
Journal Article
Open access
PDF file
Pavel FialaPavel Fiala
Pavel Fiala
PDPetr Drexler
Petr Drexler
DNDusan Nespor
Dusan Nespor
ZSZoltán Szabó
Zoltán Szabó
JMJan Mikulka
Jan Mikulka
JPJiri Polivka
Jiri Polivka
The paper discusses mathematical tools to evaluate novel noise spectroscopy based analysis and describes, via physical similarity, the mathematical models expressing the quantitative character of the modeled task. Using the Stefan–Boltzmann law, the authors indicate finding the spectral density of the radiated power of a hemisphere, and, for the selected frequency interval and temperature, they compare the simplified models with the expression of noise spectral density according to the Johnson–Nyquist formula or Nyquist’s expression of the function of spectral density based on a derivation of Planck’s law. The related measurements and evaluations, together with analyses of the noise spectroscopy of periodic resonant structures, are also outlined in the given context.

14 March 2012 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
Pavel FialaPavel Fiala
Pavel Fiala
PDPetr Drexler
Petr Drexler

9 January 2014 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
Pavel FialaPavel Fiala
Pavel Fiala
PDPetr Drexler
Petr Drexler
DND. Nespor
D. Nespor

1 February 2017 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
ZRZdeněk Roubal
Zdeněk Roubal
KBK. Bartušek
K. Bartušek
ZSZoltán Szabó
Zoltán Szabó
PDPetr Drexler
Petr Drexler
JÜJ. Überhuberová
J. Überhuberová
The paper deals with a methodology proposed for measuring the concentration of air ions in the environment of speleotherapeutic caves, and with the implementation of the AK-UTEE-v2 ionmeter. Speleotherapy, in the context of its general definition, is the medical therapy that utilizes the climate of selected caves to treat patients with health problems such as asthma. These spaces are characterized by the presence of high air humidity and they make extreme demands on the execution of the measuring device, the Gerdien tube (GT in the following) in particular, and on the amplifier electronics. The result is an automated measuring system using a GT with low-volume air flow, enabling long-term measuring of air ion concentration and determination of spectral ion characteristics. Interesting from the instrumentation viewpoint are the GT design, active shielding, and execution of the electrometric amplifier. A specific method for the calculation of spectral ion characteristics and the mode of automatic calibration were proposed and a procedure of automatic measurement in the absence of attendants was set up. The measuring system is designed for studying and long-term monitoring of the concentration of light negative ions in dependence on climatic conditions and on the mobility of ions occurring in the cave.