Pei Lay Yap

Dr. Pei Lay Yap

School of Chemical Engineering and Advanced Materials, Faculty of Engineering, Computer and Mathematical Sciences, The University of Adelaide, Adelaide, Australia
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2021 in C
Verified
Journal Article
Open access
PDF file
FFFarzaneh Farivar
Farzaneh Farivar
Pei Lay YapPei Lay Yap
Pei Lay Yap
RKRamesh Karunagaran
Ramesh Karunagaran
Dusan LosicDusan Losic
Dusan Losic
Thermogravimetric analysis (TGA) has been recognized as a simple and reliable analytical tool for characterization of industrially manufactured graphene powders. Thermal properties of graphene are dependent on many parameters such as particle size, number of layers, defects and presence of oxygen groups to improve the reliability of this method for quality control of graphene materials, therefore it is important to explore the influence of these parameters. This paper presents a comprehensive TGA study to determine the influence of different particle size of the three key materials including graphene, graphene oxide and graphite on their thermal parameters such as carbon decomposition range and its temperature of maximum mass change rate (Tmax). Results showed that Tmax values derived from the TGA-DTG carbon combustion peaks of these materials increasing from GO (558–616 °C), to graphene (659–713 °C) and followed by graphite (841–949 °C) The Tmax values derived from their respective DTG carbon combustion peaks increased as their particle size increased (28.6–120.2 µm for GO, 7.6–73.4 for graphene and 24.2–148.8 µm for graphite). The linear relationship between the Tmax values and the particle size of graphene and their key impurities (graphite and GO) confirmed in this study endows the use of TGA technique with more confidence to evaluate bulk graphene-related materials (GRMs) at low-cost, rapid, reliable and simple diagnostic tool for improved quality control of industrially manufactured GRMs including detection of “fake” graphene.

7 September 2020 in Nanoscale
Verified
Journal Article
Closed access
PDF file
KHKamrul Hassan
Kamrul Hassan
MNMd. Julker Nine
Md. Julker Nine
TTTran Tung
Tran Tung
NSNathan Stanley
Nathan Stanley
Pei Lay YapPei Lay Yap
Pei Lay Yap
Dusan LosicDusan Losic
Dusan Losic
Graphene and related 2D materials offer an ideal platform for next generation disruptive technologies and in particular the potential to produce printed electronic devices with low cost and high throughput.

16 December 2022 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
LYLe Yu
Le Yu
Pei Lay YapPei Lay Yap
Pei Lay Yap
ASAlexandre Santos
Alexandre Santos
DTDiana Tran
Diana Tran
Dusan LosicDusan Losic
Dusan Losic

20 May 2022 in 2D Materials
Verified
Journal Article
Closed access
PTPiers Turner
Piers Turner
KPKeith R Paton
Keith R Paton
ELElizabeth J Legge
Elizabeth J Legge
ABAndres de Luna Bugallo
Andres de Luna Bugallo
ARA K S Rocha-Robledo
A K S Rocha-Robledo
APAndrew J Pollard
Andrew J Pollard
There is a pressing need for reliable, reproducible and accurate measurements of graphene’s properties, through international standards, to facilitate industrial growth. However, trustworthy and verified standards require rigorous metrological studies, determining, quantifying and reducing the sources of measurement uncertainty. Towards this effort, we report the procedure and the results of an international interlaboratory comparison (ILC) study, conducted under Versailles Project on Advanced Materials and Standards. This ILC focusses on the comparability of Raman spectroscopy measurements of chemical vapour deposition (CVD) grown graphene using the same measurement protocol across different institutes and laboratories. With data gathered from 17 participants across academia, industry (including instrument manufacturers) and national metrology institutes, this study investigates the measurement uncertainty contributions from both Raman spectroscopy measurements and data analysis procedures, as well as provides solutions for improved accuracy and precision. While many of the reported Raman metrics were relatively consistent, significant and meaningful outliers occurred due to differences in the instruments and data analysis. These variations resulted in inconsistent reports of peak intensity ratios, peak widths and the coverage of graphene. Due to a lack of relative intensity calibration, the relative difference reported in the 2D- and G peak intensity ratios ( I 2 D / I G ) was up to 200%. It was also shown that the standard deviation for Γ 2 D values reported by different software packages, was 15× larger for Lorentzian fit functions than for pseudo-Voigt functions. This study has shown that by adopting a relative intensity calibration and consistent peak fitting and data analysis methodologies, these large, and previously unquantified, variations can be significantly reduced, allowing more reproducible and comparable measurements for the graphene community, supporting fundamental research through to the growing graphene industry worldwide. This project and its findings directly underpin the development of the ISO/IEC standard ‘ DTS 21356-2—Nanotechnologies—Structural Characterisation of CVD-grown Graphene ’.

26 March 2024 in C
Verified
Journal Article
Open access
PDF file
Dusan LosicDusan Losic
Dusan Losic
FFFarzaneh Farivar
Farzaneh Farivar
Pei Lay YapPei Lay Yap
Pei Lay Yap
Graphene-related two-dimensional materials available on the global market are manufactured using various production methods, with significant variations in properties and qualities causing serious concerns for the emerging multi-billion graphene industry. To address the limitations of conventional characterization methods probing the properties of individual graphene particles which may overlook the presence of non-graphene carbon impurities at a large (bulk) scale, this paper presents the refining thermogravimetric analysis as a complementary method for the reliable chemical characterization and quality control of graphene powders. A systematic parametric investigation of key experimental conditions such as sample mass and loading, heating rate, and gas environment and flow rate is performed to identify optimized settings for reliable thermal gravimetric measurements. These optimized conditions are evaluated through a series of comparative characterizations using industrially produced graphene, graphene oxide, and reduced graphene oxide powders, including their common carbon impurities. The ability of this method to provide both qualitative and quantitative analyses for characterizing graphene-related materials is confirmed. The optimized method is finally validated through an International Laboratory Comparison study and subsequently incorporated into a new standard. This low-cost, industry-affordable, and complementary characterization method is expected to enhance the quality control of manufactured graphene materials and make a valuable contribution to the growing graphene industry.

25 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
FFFarzaneh Farivar
Farzaneh Farivar
Pei Lay YapPei Lay Yap
Pei Lay Yap
TTTran Tung
Tran Tung
Dusan LosicDusan Losic
Dusan Losic
Functionalization of pristine graphene to achieve high water dispersibility remains as a key obstacle owing to the high hydrophobicity and absence of reactive functional groups on the graphene surface. Herein, a green and simple modification approach to prepare highly dispersible functionalized graphene via thermal thiol-ene click reaction was successfully demonstrated on pristine graphene. Specific chemical functionalities (–COO, –NH2 and –S) on the thiol precursor (L-cysteine ethyl ester) were clicked directly on the sp2 carbon of graphene framework with grafting density of 1 unit L-cysteine per 113 carbon atoms on graphene. This functionalized graphene was confirmed with high atomic content of S (4.79 at % S) as well as the presence of C–S–C and N–H species on the L-cysteine functionalized graphene (FG-CYS). Raman spectroscopy evidently corroborated the modification of graphene to FG-CYS with an increased intensity ratio of D and G band, ID/IG ratio (0.3 to 0.7), full-width at half-maximum of G band, FWHM [G] (20.3 to 35.5) and FWHM [2D] (64.8 to 90.1). The use of ethanol as the reaction solvent instead of common organic solvents minimizes the chemical hazards exposure to humans and the environment. This direct attachment of multifunctional groups on the surface of pristine graphene is highly demanded for graphene ink formulations, coatings, adsorbents, sensors and supercapacitor applications.