The present paper studies the thermal performance of solar air heater which is artificially roughened by providing multiple arcs with gap shaped roughness element. As thermal efficiency of smooth collector is quite low, hence there is a need to augment heat transfer from the absorbing surface. The experimentation has been carried out for Reynolds number (Re) ranges from 2100- 21000, relative roughness height (e/D) of 0.044, relative roughness pitch (p/e) of 8, relative gap distance (d/x) range of 0.25- 0.85, relative roughness width (W/w) ranges from 1-7, relative gap width (g/e) range of 0.5-2 and arc angle (a) of 60°. The thermal efficiency is found to be best for relative gap distance (d/x), relative gap width (g/e) and relative roughness width (W/w) values are 0.65, 1.0 and 5 respectively.Keywords: Solar air heater; Nusselt number; thermal efficiency; multiple arcs with gap; roughened
28 September 2020 in International Journal of Ambient Energy
Repeated rib elements are used as roughness medium to increase heat transfer. An experimental and numerical analysis has been performed to study the influence of number of gaps on absorber plates pasted with arc shaped roughness elements with gaps to study the heat transfer (Nu) and friction factor (f) used in solar air-heaters (SAHs). ANSYS was used to simulate the air flow through a rectangular passage. A heating source of 1000 W/m2 was provided on the top of the surface to simulate the radiant energy of the sun. Twenty seven combinations of roughened duct were investigated using the software as well as on an experimental setup. The result shows that the highest value of Nu was obtained for roughness element which is having number of gaps equal to 2. Thermo-hydraulic efficiency parameter has also been evaluated for the same.
Modern applications for distributed publish/subscribe systems often require stream aggregation capabilities along with rich data filtering. When compared to other distributed systems, aggregation in pub/sub differentiates itself as a complex problem which involves dynamic dissemination paths that are difficult to predict and optimize for a priori, temporal fluctuations in publication rates, and the mixed presence of aggregated and non-aggregated workloads. In this paper, we propose a formalization for the problem of minimizing communication traffic in the context of aggregation in pub/sub. We present a solution to this minimization problem by using a reduction to the well-known problem of minimum vertex cover in a bipartite graph. This solution is optimal under the strong assumption of complete knowledge of future publications. We call the resulting algorithm "Aggregation Decision, Optimal with Complete Knowledge" (ADOCK). We also show that under a dynamic setting without full knowledge, ADOCK can still be applied to produce a low, yet not necessarily optimal, communication cost. We also devise a computationally cheaper dynamic approach called "Aggregation Decision with Weighted Publication" (WAD). We compare our solutions experimentally using two real datasets and explore the trade-offs with respect to communication and computation costs.
14 October 2022 in International Journal of Ambient Energy
Solar air heaters are used for various drying and room heating purpose. Techniques have been developed to increase its effectiveness by various methods, the most common being the introduction of roughness elements on the underside of the absorber plate.The current study a combined approach of response surface methodology and experimental findings has been done to investigate using various dimensionless parameters on the thermo-hydraulic performance parameters of solar air heaters with multi-arc shaped roughness elements with gaps on the absorber plate. RSM modelling was carried out with objective functions as maximization of Nusselt number and minimization of Friction factor. Optimized calculated values of design parameters for THPP of SAH to provide maximum Nusselt number were estimated as Reynolds Number = 21000, e/D = 0.0443, d/x = 0.25 and g/e = 1.7323. The enhancement ratio of Friction factor and Nusselt number were found to be 2.101 and 3.53 respectively.