Zhizeng Wang

Dr. Zhizeng Wang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
YWYangyang Wang
Yangyang Wang
KZKaixuan Zheng
Kaixuan Zheng
WZWenhao Zhan
Wenhao Zhan
LHLuyu Huang
Luyu Huang
YLYidan Liu
Yidan Liu
ZWZhizeng Wang
Zhizeng Wang
Heavy metal contamination in soil has attracted great attention worldwide. In situ stabilization has been considered an effective way to remediate soils contaminated by heavy metals. In the present research, a multiple-modified biochar (BCM) was prepared to stabilize Cd and Cu contamination in two different soils: a farmland soil (JYS) and a vegetable soil (ZZS). The results showed that BCM was a porous-like flake material and that modification increased its specific surface area and surface functional groups. The incubation experiment indicated that BCM decreased diethylenetriaminepentaacetic (DTPA)-extractable Cd and Cu by 92.02% and 100.00% for JYS and 90.27% and 100.00% for ZZS, respectively. The toxicity characteristic leaching procedure (TCLP)-extractable Cd and Cu decreased 66.46% and 100.00% for JYS and 46.33% and 100.00% for ZZS, respectively. BCM also reduced the mobility of Cd and Cu in soil and transformed them to more stable fractions. In addition, the application of BCM significantly increased the soil dehydrogenase, organic matter content and available K (p < 0.05). These results indicate that BCM has great potential in the remediation of Cd- and Cu-contaminated soil.

7 October 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ZWZhizeng Wang
Zhizeng Wang
ZZZhi Zheng
Zhi Zheng
HHHangzhan Hu
Hangzhan Hu
QZQianwen Zhou
Qianwen Zhou
WLWei Liu
Wei Liu
YMYuanfang Ma
Yuanfang Ma
COVID-19 is a widespread and highly contagious disease in the human population. COVID-19 is caused by SARS-CoV-2 infection. There is still a great demand for point-of-care tests for detection, epidemic prevention and epidemiological investigation, both now and after the epidemic. We present a lateral flow immunoassay kit based on a selenium nanoparticle-modified SARS-CoV-2 nucleoprotein, which detects anti-SARS-CoV-2 IgM and anti-SARS-CoV-2 IgG in human serum, and the results can be read by the naked eye in 10 minutes. We expressed and purified the SARS-CoV-2 nucleoprotein in HEK293 cells, with a purity of 98.14% and a concentration of 5 mg mL−1. Selenium nanoparticles were synthesized by L-ascorbic acid reduction of seleninic acid at room temperature. After conjugation with the nucleoprotein, a lateral flow kit was successfully prepared. The IgM and IgG detection limits of the lateral flow kit reached 20 ng mL−1 and 5 ng mL−1, respectively, in human serum. A clinical study sample comprising 90 COVID-19-diagnosed patients and 263 non-infected controls was used to demonstrate a sensitivity and specificity of 93.33% and 97.34%, respectively, based on RT-PCR and clinical results. No cross-reactions with rheumatoid factor and positive serum for anti-nuclear antibodies, influenza A, and influenza B were observed. Moreover, the lateral flow kit remained stable after storage for 30 days at 37 °C. Our results demonstrate that the selenium nanoparticle lateral flow kit can conveniently, rapidly, and sensitively detect anti-SARS-CoV-2 IgM and IgG in human serum and blood; it can also be suitable for the epidemiological investigation of COVID-19.

1 January 2019 in Materials Letters
Verified
Journal Article
Open access
ZWZhizeng Wang
Zhizeng Wang
JJJing Jing
Jing Jing
YRYangguang Ren
Yangguang Ren
YGYafei Guo
Yafei Guo
NTNingya Tao
Ningya Tao
YWYaohui Wang
Yaohui Wang

18 August 2021 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Open access
CCChunxia Chen
Chunxia Chen
HHHangzhan Hu
Hangzhan Hu
XLXiaoquan Li
Xiaoquan Li
ZZZhi Zheng
Zhi Zheng
ZWZhizeng Wang
Zhizeng Wang
YMYuanfang Ma
Yuanfang Ma
Coronavirus disease 2019 is an infectious disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). SARS-CoV-2 is highly transmissible. Early and rapid testing is necessary to effectively prevent and control the outbreak. Detection of SARS-CoV-2 antibodies with lateral flow immunoassay can achieve this goal. In this study, SARS-CoV-2 nucleoprotein (NP) was expressed and purified. We used the selenium nanoparticle as the labeling probe coupled with the NP to prepare an antibody (IgM and IgG) detection kit. The detection limit, cross reaction, sensitivity and specificity of the kit is verified. Separate detection of IgM and IgG, such as in this assay, was performed in order to reduce mutual interference and improve the accuracy of the test results.The final purity of NP was 91.83%. Selenium nanoparticle and NP successfully combined with stable effect. The LOD of the kit was 20 ng/mL for anti-NP IgG and 60 ng/mL for anti-NP IgM, respectively. The kit does not cross reaction with RF. The sensitivity of the kit was 94.74% and the specificity was 96.23%. The assay kit does not require any special device for reading the results and the readout is a simple color change that can be evaluated with the naked eye. This kit is suitable for rapid and real-time detection of the SARS-CoV-2 antibody IgG and IgM.

22 April 2020 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
YWYaohui Wang
Yaohui Wang
HZHailong Zhang
Hailong Zhang
ZWZhizeng Wang
Zhizeng Wang
YWYinxiang Wei
Yinxiang Wei
MWMingli Wang
Mingli Wang
YMYuanfang Ma
Yuanfang Ma
TRAIL blockade limits cardiac cell death and reduces inflammation to improve cardiac function after myocardial infarction in rats, pigs, and monkeys.

1 March 2021 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
ZWZhizeng Wang
Zhizeng Wang
QZQianqwen Zhou
Qianqwen Zhou
YGYafei Guo
Yafei Guo
HHHangzhan Hu
Hangzhan Hu
ZZZhi Zheng
Zhi Zheng
YMYuanfang Ma
Yuanfang Ma
Purpose: The purpose of this study was to establish a lateral flow immunoassay using selenium nanoparticles (Se-NPs) as a probe to detect ractopamine (RAC) and salbutamol (SAL) in swine urine. Methods: SDS and PEG were used as templates to prepare Se-NPs; anti-RAC monoclonal antibodies or anti-SAL monoclonal antibodies were labelled with Se-NPs; and rapid detection kits were prepared. The sensitivity, specificity, and stability were measured, and actual samples were analysed. Results: The Se-NPs were spherical with a diameter of 40.63 ± 5.91 nm, and were conjugated successfully with an anti-RAC antibody to give a total diameter of 82.33 ± 17.91 nm. The detection limit of a RAC kit in swine urine was 1 ng/mL, and that of a SAL kit was 3 ng/mL. Both procedures could be completed within 5 minutes. No cross-reaction occurred with clenbuterol, bambuterol and phenylethanolamine A. Samples were tested consistently across different batches of kits for swine urine. The results of the kits were identical to those of actual clinical samples analysed by ELISA, and the coincidence rate was 100%. Conclusion: The assay kit does not require any special device for reading the results, and the readout is a simple colour change that can be evaluated with the naked eye. It is easy to operate, sensitive, specific, and stable This kit is suitable for the rapid and real-time detection of RAC and SAL residues in swine urine samples. Clinical Trial Registration: Swine urines samples were used under approval from the Experimental Animal Ethics committee of the Joint National Laboratory for Antibody Drug Engineering, Henan University.