Magdalini TITIRLA

Dr. Magdalini TITIRLA

Laboratoire de Mécanique des Structures et des Systèmes Couplés (LMSSC), Conservatoire national des arts et métiers (Cnam), Paris, France
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Magdalini TITIRLAMagdalini TITIRLA
Magdalini TITIRLA
An extensive investigation of the international literature is carried out regarding the passive energy dissipation systems and more specifically the dampers that can be positioned in steel braces to increase the absorption of seismic energy and to protect them from buckling, such as Friction (FDs), Metallic (MDs), and Viscous dampers (VDs). This review paper systematically reviews/refers to 196 publications from the literature; it presents a brief overview of the steel braces frames and their problems. The efficacy of all of these types of dampers has been proved, as they have been used all around the world, and their comparison in experimental or numerical studies, applications, and optimization shows that there is no unilateral solution, as the appropriate selection of effective retrofit strategies takes into account parameters such as cost, duration, technical aspects, architectural needs, etc. Finally, the aim of this review paper is to systematically present an overview of passive energy dampers that can be installed on steel braces, summarize the advantages and the disadvantages of each one, compare global parameters such as the relation of velocity and damper force, economic details, and type of study, and facilitate future researchers working in the related field, for its better understanding and development.


1 August 2018 in Engineering Structures
Verified
Journal Article
Closed access
Magdalini TITIRLAMagdalini TITIRLA
Magdalini TITIRLA
PPPanikos K. Papadopoulos
Panikos K. Papadopoulos
IDIoannis N. Doudoumis
Ioannis N. Doudoumis

28 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CMCharbel Mrad
Charbel Mrad
Magdalini TITIRLAMagdalini TITIRLA
Magdalini TITIRLA
WLWalid Larbi
Walid Larbi
The aim of this study is to compare the seismic response of reinforced concrete (RC) symmetric buildings, with a varied number of stories, strengthening with three types of passive energy dissipation systems, as tuned mass dampers, viscous dampers, and friction dampers. The paper presents an overview of design optimization with the object of minimizing certain functions: (i) the maximum displacement at the top of the structures, (ii) the base shear loads, and (iii) the maximum interstory drift. The objective functions were evaluated in three residents’ buildings (a four-story building, a nine-story building, and a sixteen-story building) subjected to seven (real and artificial) seismic recorded accelerograms. For this purpose, 94 nonlinear dynamic analyses were carried out. The effects of each strengthening solution are presented, and from this innovative comparison (optimal design, three different passive energy systems, three different story numbers), further useful results were observed. The outcomes of the study show the effectiveness of a tuned mass damper (TMD) system, and how it might be better for tall and flexible structures than for stiffer structures. However, the response of the pendulum tuned mass damper (TMD) configuration is better than the conventional one because it acts in all directions. The viscous dampers (VDs) provide a significant reduction for mid-rise buildings, while friction dampers (FDs) boost the performance of all structures under seismic action, especially in terms of displacement, and they are more suitable for low-rise buildings.

1 May 2014 in Engineering Structures
Verified
Journal Article
Closed access
SMStergios-Aristoteles Mitoulis
Stergios-Aristoteles Mitoulis
Magdalini TITIRLAMagdalini TITIRLA
Magdalini TITIRLA
ITI.A. Tegos
I.A. Tegos

24 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Magdalini TITIRLAMagdalini TITIRLA
Magdalini TITIRLA
In the present work attention is focused on the friction-yielding damper CAR1 (first prototype of Control-Absorb-Retain damper), which belongs to passive energy dissipation systems. This damper consists of very simple materials; it does not need to be accomplished in heavy industry so enables its use in both developing and undeveloped countries. This paper presents and compares two alternative solutions with the use of the CAR1 to seismic retrofit an existing two-story reinforced-concrete (RC) structure with a moment-resisting frame located in Greece and constructed in 1979 and no longer meets the requirements of current anti-seismic regulations. A nonlinear static pushover analysis is performed to assess the performance of the framed building under different levels of shaking (“Life Safety” and “Collapse”). The pushover analysis is carried out in both the x and y directions. The use of damper CAR1 in seismic retrofitting not only provides a base shear load of up to 149.2% and 135.6% for the first and second redesign solutions but also protects steel diagonal braces from buckling. The appropriate characteristics of the dampers CAR1 has been selected from a wide variety of choices and the strengthening level can be easily adjusted or modified during the years based to the appropriate selection or modification of the number, the dimensions, and the elastoplastic properties of the blades.