Asal Bidarmaghz

Dr. Asal Bidarmaghz

School of Civil and Environmental Engineering, The University of New South Wales, Sydney, NSW 2052, Australia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Geomechanics for Energy and the Environment
Verified
Journal Article
Closed access
ABAsal Bidarmaghz
Asal Bidarmaghz
GNGuillermo Narsilio
Guillermo Narsilio

1 June 2016 in Geomechanics for Energy and the Environment
Verified
Journal Article
Closed access
ABAsal Bidarmaghz
Asal Bidarmaghz
GNGuillermo Narsilio
Guillermo Narsilio
IJIan W. Johnston
Ian W. Johnston
SCStuart Colls
Stuart Colls

1 January 2020 in Science of The Total Environment
Verified
Journal Article
Closed access
ABAsal Bidarmaghz
Asal Bidarmaghz
RCRuchi Choudhary
Ruchi Choudhary
KSKenichi Soga
Kenichi Soga
RTRicky L. Terrington
Ricky L. Terrington
HKHolger Kessler
Holger Kessler
STStephen Thorpe
Stephen Thorpe

1 July 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
ABAsal Bidarmaghz
Asal Bidarmaghz
RCRuchi Choudhary
Ruchi Choudhary
GNGuillermo Narsilio
Guillermo Narsilio
KSKenichi Soga
Kenichi Soga

30 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
YZYu ZHOU
Yu ZHOU
ABAsal Bidarmaghz
Asal Bidarmaghz
NMNikolas Makasis
Nikolas Makasis
GNGuillermo Narsilio
Guillermo Narsilio
Ground-source heat pump systems are renewable and highly efficient HVAC systems that utilise the ground to exchange heat via ground heat exchangers (GHEs). This study developed a detailed 3D finite element model for horizontal GHEs by using COMSOL Multiphysics and validated it against a fully instrumented system under the loading conditions of rural industries in NSW, Australia. First, the yearly performance evaluation of the horizontal straight GHEs showed an adequate initial design under the unique loads. This study then evaluated the effects of variable trench separations, GHE configurations, and effective thermal conductivity. Different trench separations that varied between 1.2 and 3.5 m were selected and analysed while considering three different horizontal loop configurations, i.e., the horizontal straight, slinky, and dense slinky loop configurations. These configurations had the same length of pipe in one trench, and the first two had the same trench length as well. The results revealed that when the trench separation became smaller, there was a minor increasing trend (0.5 °C) in the carrier fluid temperature. As for the configuration, the dense slinky loop showed an average that was 1.5 °C lower than those of the horizontal straight and slinky loop (which were about the same). This indicates that, when land is limited, compromises on the trench separation should be made first in lieu of changes in the loop configuration. Lastly, the results showed that although the effective thermal conductivity had an impact on the carrier fluid temperature, this impact was much lower compared to that for the GHE configurations and trench separations.

7 November 2024 in Computers and Geotechnics
Verified
Journal Article
Open access
AKArvind Kumar
Arvind Kumar
ABAsal Bidarmaghz
Asal Bidarmaghz
Arman KhoshghalbArman Khoshghalb
Arman Khoshghalb
KSKenichi Soga
Kenichi Soga