Luigi Calzolai

Dr. Luigi Calzolai

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Journal of Colloid and Interface Science
Verified
Journal Article
Open access
FCF. Caputo
F. Caputo
RVR. Vogel
R. Vogel
JSJ. Savage
J. Savage
GVG. Vella
G. Vella
ALA. Law
A. Law
LCLuigi Calzolai
Luigi Calzolai
The implementation of the proposal from the European Chemical Agency (ECHA) to restrict the use of nanoplastics (NP) and microplastics (MP) in consumer products will require reliable methods to perform size and mass-based concentration measurements. Analytical challenges arise at the nanometre to micrometre interface, e.g., 800 nm-10 µm, where techniques applicable at the nanometre scale reach their upper limit of applicability and approaches applicable at the micrometre scale must be pushed to their lower limits of detection. Herein, we compared the performances of nine analytical techniques by measuring the particle size distribution and mass-based concentration of polystyrene mixtures containing both nano and microparticles, with the educational aim to underline applicability and limitations of each technique. Light scattering-based measurements do not have the resolution to distinguish multiple populations in polydisperse samples. Nanoparticle tracking analysis (NTA), nano-flowcytometry (nFCM) and asymmetric flow field flow fractionation hyphenated with multiangle light scattering (AF4-MALS) cannot measure particles in the micrometre range. Static light scattering (SLS) is not able to accurately detect particles below 200 nm, and similarly to transmission electron microscopy (TEM) and flow cytometry (FCM), is not suitable for accurate mass-based concentration measurements. Alternatives for high-resolution sizing and concentration measurements in the size range between 60 nm and 5 µm are tunable resistive pulse sensing (TRPS) and centrifugal liquid sedimentation (CLS), that can bridge the gap between the nanometre and micrometre range.

16 June 2022 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
GGGiuditta Guerrini
Giuditta Guerrini
DMDavide Magrì
Davide Magrì
SGSabrina Gioria
Sabrina Gioria
DMDonata Medaglini
Donata Medaglini
LCLuigi Calzolai
Luigi Calzolai

25 March 2021 in Nature
Verified
Journal Article
Closed access
PDF file
RGRaoul De Gasparo
Raoul De Gasparo
MPMattia Pedotti
Mattia Pedotti
LSLuca Simonelli
Luca Simonelli
PNPetr Nickl
Petr Nickl
FMFrauke Mücksch
Frauke Mücksch
Luca VaraniLuca Varani
Luca Varani

12 January 2021 in Journal of Extracellular Vesicles
Verified
Journal Article
Open access
PDF file
RVRobert Vogel
Robert Vogel
JSJohn Savage
John Savage
JMJulien Muzard
Julien Muzard
GCGiacomo Della Camera
Giacomo Della Camera
GVGabriele Vella
Gabriele Vella
APAdriele Prina-Mello
Adriele Prina-Mello
The measurement of physicochemical properties of polydisperse complex biological samples, for example, extracellular vesicles, is critical to assess their quality, for example, resulting from their production and isolation methods. The community is gradually becoming aware of the need to combine multiple orthogonal techniques to perform a robust characterization of complex biological samples. Three pillars of critical quality attribute characterization of EVs are sizing, concentration measurement and phenotyping. The repeatable measurement of vesicle concentration is one of the key‐challenges that requires further efforts, in order to obtain comparable results by using different techniques and assure reproducibility. In this study, the performance of measuring the concentration of particles in the size range of 50–300 nm with complementary techniques is thoroughly investigated in a step‐by step approach of incremental complexity. The six applied techniques include multi‐angle dynamic light scattering (MADLS), asymmetric flow field flow fractionation coupled with multi‐angle light scattering (AF4‐MALS), centrifugal liquid sedimentation (CLS), nanoparticle tracking analysis (NTA), tunable resistive pulse sensing (TRPS), and high‐sensitivity nano flow cytometry (nFCM). To achieve comparability, monomodal samples and complex polystyrene mixtures were used as particles of metrological interest, in order to check the suitability of each technique in the size and concentration range of interest, and to develop reliable post‐processing data protocols for the analysis. Subsequent complexity was introduced by testing liposomes as validation of the developed approaches with a known sample of physicochemical properties closer to EVs. Finally, the vesicles in EV containing plasma samples were analysed with all the tested techniques. The results presented here aim to shed some light into the requirements for the complex characterization of biological samples, as this is a critical need for quality assurance by the EV and regulatory community. Such efforts go with the view to contribute to both, set‐up reproducible and reliable characterization protocols, and comply with the Minimal Information for Studies of Extracellular Vesicles (MISEV) requirements.

31 March 2023 in Science Immunology
Verified
Journal Article
Closed access
FBFilippo Bianchini
Filippo Bianchini
VCVirginia Crivelli
Virginia Crivelli
MAMorgan E. Abernathy
Morgan E. Abernathy
CGConcetta Guerra
Concetta Guerra
Martin PalusMartin Palus
Martin Palus
DRDavide F. Robbiani
Davide F. Robbiani
Emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants diminishes the efficacy of vaccines and antiviral monoclonal antibodies. Continued development of immunotherapies and vaccine immunogens resilient to viral evolution is therefore necessary. Using coldspot-guided antibody discovery, a screening approach that focuses on portions of the virus spike glycoprotein that are both functionally relevant and averse to change, we identified human neutralizing antibodies to highly conserved viral epitopes. Antibody fp.006 binds the fusion peptide and cross-reacts against coronaviruses of the four genera, including the nine human coronaviruses, through recognition of a conserved motif that includes the S2′ site of proteolytic cleavage. Antibody hr2.016 targets the stem helix and neutralizes SARS-CoV-2 variants. Antibody sd1.040 binds to subdomain 1, synergizes with antibody rbd.042 for neutralization, and, similar to fp.006 and hr2.016, protects mice expressing human angiotensin-converting enzyme 2 against infection when present as a bispecific antibody. Thus, coldspot-guided antibody discovery reveals donor-derived neutralizing antibodies that are cross-reactive with Orthocoronavirinae, including SARS-CoV-2 variants.

1 January 2021 in Journal of Chromatography A
Verified
Journal Article
Open access
FCF. Caputo
F. Caputo
DMD. Mehn
D. Mehn
Jeffrey ClogstonJeffrey Clogston
Jeffrey Clogston
MRM. Rösslein
M. Rösslein
APA. Prina-Mello
A. Prina-Mello
LCLuigi Calzolai
Luigi Calzolai
Asymmetric-flow field-flow fractionation (AF4) has been recognized as an invaluable tool for the characterisation of particle size, polydispersity, drug loading and stability of nanopharmaceuticals. However, the application of robust and high quality standard operating procedures (SOPs) is critical for accurate measurements, especially as these complex drug nanoformulations are most often inherently polydisperse. In this review we describe a unique international collaboration that lead to the development of a robust SOP for the measurement of physical-chemical properties of nanopharmaceuticals by multi-detector AF4 (MD-AF4) involving two state of the art infrastructures in the field of nanomedicine, the European Union Nanomedicine Characterization Laboratory (EUNCL) and the National Cancer Institute-Nanotechnology Characterisation Laboratory (NCI-NCL). We present examples of how MD-AF4 has been used for the analysis of key quality attributes, such as particle size, shape, drug loading and stability of complex nanomedicine formulations. The results highlight that MD-AF4 is a very versatile analytical technique to obtain critical information on a material particle size distribution, polydispersity and qualitative information on drug loading. The ability to conduct analysis in complex physiological matrices is an additional very important advantage of MD-AF4 over many other analytical techniques used in the field for stability studies. Overall, the joint NCI-NCL/EUNCL experience demonstrates the ability to implement a powerful and highly complex analytical technique such as MD-AF4 to the demanding quality standards set by the regulatory authorities for the pre-clinical safety characterization of nanomedicines.