Žaneta Eleschová

Dr. Žaneta Eleschová

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2022 in Processes
Verified
Journal Article
Open access
PDF file
JBJozef Bendík
Jozef Bendík
Matej CenkýMatej Cenký
Matej Cenký
BCBoris Cintula
Boris Cintula
ABAnton Beláń
Anton Beláń
ŽEŽaneta Eleschová
Žaneta Eleschová
PJPeter Janiga
Peter Janiga
In recent years, the emerging fear of an energy crisis in central Europe has caused an increased demand for distributed energy resources (DER), especially small photovoltaic rooftop installations up to 10 kWp. From a technical point of view, distributed PV in low-voltage networks is associated with the risk of power quality violation, overvoltage, voltage unbalance, harmonics, and violation of the thermal limit of phase conductors, neutral conductors, and transformers. Distribution system operators (DSO) are currently in a position to determine the amount of installed PV power for which reliable and safe network operation is ensured, also known as the photovoltaic hosting capacity (PVHC). The presented study describes a stochastic methodology for PVHC estimation and uses it to analyze a typical LV rural network in the Slovak Republic. Detailed and precise calculations are performed on the 4-wire LV model with accurate results. In this study, we, thus, profoundly analyze the problems with voltage violation, unbalanced voltage energy losses, and the thermal loading effect of increasing PV penetration. The results show that overvoltage events are the main factor limiting the PVHC in LV systems. This conclusion is in accordance with the experience of the DSO in the Slovak and Czech Republic. Subsequently, the study focuses on the possibilities of increasing PVHC using those tools typically available for DSO, such as changes in PV inverter power factors and no-load tap changer transformers. The results are compared with those derived from similar analyses, but we ultimately find that the proposed solution is problematic due to the high variability of approaches and boundary conditions. In conclusion, the paper discusses the issue of the acceptable risk of overvoltage violation in the context of PVHC and lowering losses in LV networks.

3 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
BCBoris Cintula
Boris Cintula
ŽEŽaneta Eleschová
Žaneta Eleschová
Matej CenkýMatej Cenký
Matej Cenký
PJPeter Janiga
Peter Janiga
JBJozef Bendík
Jozef Bendík
ABAnton Beláň
Anton Beláň
Calculation and measurement of the overhead power lines electrical parameters is common practice in today’s electrical engineering industry; however, there is very little data to actually compare these two approaches because measured data in such detail are mostly unavailable for academic purposes. Based on the very detailed model of an overhead power line in MATLAB Simulink environment and conducted experimental measurement, this article specifically covers the exact evaluation of the impedance of the investigated overhead power line. Differences between calculation and experimental measurement are shown and discussed accordingly, where, surprisingly, the biggest deviation was observed in the positive resistance parameter. The connection between different measurement techniques (multiple single-phase and three-phase methods), as well as the power line asymmetry reflection in the impedance matrix is explained as well as compared to expected values from the computations. The complete mathematical approach for electrical parameters evaluation from different measurement methods is explained step-by-step, and the final equations are introduced for each method. Proposed methods of obtaining the electrical parameters of the power line are then concluded as the ones with great accuracy and wide usage in practical applications. It shows the great importance of correct input data for the electrical parameters’ theoretical computations and the need to know the measurement methodology and apparatus perfectly to process the measured data and interpret them correctly.

13 January 2023 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Matej CenkýMatej Cenký
Matej Cenký
JBJozef Bendík
Jozef Bendík
BCBoris Cintula
Boris Cintula
PJPeter Janiga
Peter Janiga
ABAnton Beláň
Anton Beláň
ŽEŽaneta Eleschová
Žaneta Eleschová

21 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
ABAnton Beláň
Anton Beláň
BCBoris Cintula
Boris Cintula
Matej CenkýMatej Cenký
Matej Cenký
PJPeter Janiga
Peter Janiga
JBJozef Bendík
Jozef Bendík
AŠAdam Šimurka
Adam Šimurka
The current transformation of power systems is aiming towards distributed source integration and general decentralization. Renewable energy sources and support of local energy supply create conditions for widespread use of new technologies and smart grids. As the electrical grids become more electrically independent, the importance of frequency control will rise. Stability of the system in such cases is no longer only relying on rotating inertia of generators as in the centralized grid. This known scenario has already been analyzed by many with computational models for optimal safety precautions of the grid. This paper aims to update the common home appliance frequency characteristics through measurements and compare them to those currently used. These devices were divided into two groups: general categorization and light sources. Subsequently, the frequency sensitivity coefficients were evaluated and analyzed home appliances were sorted into three categories according to the size of their frequency sensitivity coefficient values: positive, negative, and no effect. The results were compared with studies aimed at evaluating the static load characteristics. A simplified simulation of the frequency control, presented in the discussion section, was carried out to determine the consequences of the newly measured characteristics and concludes the paper.

6 December 2022 in Processes
Verified
Journal Article
Open access
PDF file
ŽEŽaneta Eleschová
Žaneta Eleschová
BCBoris Cintula
Boris Cintula
Matej CenkýMatej Cenký
Matej Cenký
ABAnton Beláň
Anton Beláň
JBJozef Bendík
Jozef Bendík
PJPeter Janiga
Peter Janiga
This paper studies the voltage stability of the Slovak Republic’s power system (PS) based on an assessment of the PV curves. The PV curve is a tool for assessing voltage stability, and based on its shape, it is possible to determine weak and strong voltage nodes with the possibility of voltage stability reserve quantification. We present an analysis of the influence of transformers with an automatic voltage regulator (AVR) on the shape of the PV curves and on the magnitude of voltage in the PS. In general, the 400 kV/110 kV transformers equipped with AVRs are critical assets for the PS as they address voltage control in the DS. However, in the case of voltage problems in the TS, the AVR function may worsen the voltage situation across the entire PS. Therefore, we closely analyze the negative effects of the AVR on the PS operation. This impact is clearly proved, and recommendations are given for the transmission system operator (TSO) in order to maintain voltage stability. In addition, the PV curves of the pilot nodes are analyzed very accurately, thereby confirming their importance in the TS in terms of a sufficient reserve of reactive power. The study was conducted in cooperation with the TSO, Slovenská elektrizačná prenosová sústava, a.s.

28 June 2021 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
ŽEŽaneta Eleschová
Žaneta Eleschová
ABAnton Beláň
Anton Beláň
MCMatej Cenký
Matej Cenký
JBJozef Bendík
Jozef Bendík
BCBoris Cintula
Boris Cintula
PJPeter Janiga
Peter Janiga
This work refers to the concept of online monitoring of generators' dynamic stability based on the critical clearing time (hereinafter referred to as "CCT"). The CCT may be considered a basic criterion of the dynamic stability of a synchronous generator. The work presents an analysis of factors (operating condition of a generator, short-circuit power of the system, increase of the proportion of distributed production in the distribution system (hereinafter referred to as "DS ") influencing the CCT and analysis of possibilities to increase the value of the CCT. In this work, we present a relatively simple concept built on the calculation of the CCT using a swing equation, which may be implemented into the dispatch control of power systems (hereinafter referred to as "PS").