The rapid and presumptive detection of SARS-CoV-2 variants may be performed using multiplex RT-PCR assays. The aim of this study was to evaluate the diagnostic performance of five qualitative RT-PCR tests as compared with next-generation sequencing (NGS). We retrospectively examined a multi-variant panel (n = 72) of SARS-CoV-2-positive nasopharyngeal swabs categorized as variants of concern (Alpha, Beta, Gamma and Delta), variants under monitoring (Iota and Kappa) and wild-type strains circulating in Liguria (Italy) from January to August 2021. First, NGS libraries of study samples were prepared and mapped to the reference genome. Then, specimens were screened for the detection of L452R, W152C, K417T, K417N, E484Q, E484K and N501Y mutations using the SARS-CoV-2 Variants II Assay Allplex, UltraGene Assay SARS-CoV-2 452R & 484K & 484Q Mutations V1, COVID-19 Ultra Variant Catcher, SARS-CoV-2 Extended ELITe MGB and Simplexa SARS-CoV-2 Variants Direct. The overall accuracy of these assays ranged from 96.9% to 100%. Specificity and sensitivity were 100% and 96–100%, respectively. We highly recommend the use of these assays as second-level tests in the routine workflow of SARS-CoV-2 laboratory diagnostics, as they are accurate, user friendly, low cost, may identify specific mutations in about 2–3 h and, therefore, optimize the surveillance of SARS-CoV-2 variants.
Background: The ongoing SARS-CoV-2 pandemic requires the availability of accurate and rapid diagnostic tests, especially in such clinical settings as emergency and intensive care units. The objective of this study was to evaluate the diagnostic performance of the Vivalytic SARS-CoV-2 rapid PCR kit in lower respiratory tract (LRT) specimens. Methods: Consecutive LRT specimens (bronchoalveolar lavage and bronchoaspirates) were collected from Intensive Care Units of San Martino Hospital (Genoa, Italy) between November 2020 and January 2021. All samples underwent RT-PCR testing by means of the Allplex™ SARS-CoV-2 assay (Seegene Inc., South Korea). On the basis of RT-PCR results, specimens were categorized as negative, positive with high viral load [cycle threshold (Ct) ≤ 30] and positive with low viral load (Ct of 31–35). A 1:1:1 ratio was used to achieve a sample size of 75. All specimens were subsequently tested by means of the Vivalytic SARS-CoV-2 rapid PCR assay (Bosch Healthcare Solutions GmbH, Germany). The diagnostic performance of this assay was assessed against RT-PCR through the calculation of accuracy, Cohen’s κ, sensitivity, specificity and expected positive (PPV) and negative (NPV) predictive values. Results: The overall diagnostic accuracy of the Vivalytic SARS-CoV-2 was 97.3% (95% CI: 90.9–99.3%), with an excellent Cohen’s κ of 0.94 (95% CI: 0.72–1). Sensitivity and specificity were 96% (95% CI: 86.5–98.9%) and 100% (95% CI: 86.7–100%), respectively. In samples with high viral loads, sensitivity was 100% (Table 1). The distributions of E gene Ct values were similar (Wilcoxon’s test: p = 0.070), with medians of 35 (IQR: 25–36) and 35 (IQR: 25–35) on Vivalytic and RT-PCR, respectively (Fig. 1). NPV and PPV was 92.6% and 100%, respectively. Conclusions: Vivalytic SARS-CoV-2 can be used effectively on LRT specimens following sample liquefaction. It is a feasible and highly accurate molecular procedure, especially in samples with high viral loads. This assay yields results in about 40 min, and may therefore accelerate clinical decision-making in urgent/emergency situations.
Accurate and rapid molecular diagnosis of COVID-19 is a crucial step to tackle the ongoing pandemic. The primary objective of this study was to estimate the real-world performance of the novel RT-PCR STANDARD M10 SARS-CoV-2 assay in a large number of nasopharyngeal (NP) specimens eluted in universal transport medium. The secondary objective was to evaluate the compatibility of this kit in testing NP samples eluted in an inactivated transport medium (essential for point-of-care testing) and lower respiratory tract (LRT) specimens, which are commonly collected in critical care. A total of 591 samples were analyzed. Compared with the standard extraction-based RT-PCR Allplex 2019-nCoV (time-to-result of 270 min), the sensitivities of the STANDARD M10 were 100% (95% CI: 98.1–100%), 95.5% (95% CI: 91.7–97.6%), and 99.5% (95% CI: 97.2–99.9%) for ≥1 gene, the ORF1ab gene, and the E gene, respectively, while the specificity was 100% (95% CI: 98.7–100%). The diagnostic accuracy was 100% in testing both NP samples eluted in an inactivated transport medium and LRT specimens. STANDARD M10 reliably detects SARS-CoV-2 in 60 min, may be used as a POC tool, and is suitable for testing LRT specimens in the critical care setting.
Background: This study aimed to investigate SARS-CoV-2 transmission among co-workers at the University of Genoa, Italy, during the second COVID-19 pandemic wave. Methods: A cross-sectional study was carried out in October 2020 – March 2021: RT-PCR confirmed cases of COVID-19 notified to the Occupational Health Service were included in the analysis. Results: Among the n = 201 notified cases, contact tracing of n = 53 individuals identified n = 346 close contacts. The household setting (IRR = 36.8; 95% CI: 4.9-276.8; p < 0.001) and sharing eating areas (IRR = 19.5; 95% CI: 2.5-153.9; p = 0.005) showed the highest Secondary Attack Rates (SARs) compared to the office setting. Fatigue (IRR= 17.1; 95% CI: 5.2-55.8; p < 0.001), gastrointestinal symptoms (IRR= 6.6; 95% CI: 2.9-15.2; p< 0.001) and cough (IRR= 8.2; 95% CI: 3.7-18.2; p= p< 0.001) were associated with transmission of infection. Polysymptomatic cases (IRR= 23.1; 95% CI: 3.1-169.2; p = 0.02) were more likely to transmit the infection. Among COVID-19 index cases aged >60 years (OR = 7.7; 95% CI: 1.9-31.9; p = 0.0046) SARs were higher than in other age groups. Wearing respiratory protections by both the case and the close contact resulted an effective measure compared with no use (IRR = 0.08; 95% CI: 0.03-0.2; p = < 0.0001). Conclusions: Accurate infection monitoring and contact tracing was useful to identify the main situations Conclusions: Accurate infection monitoring and contact tracing was useful to identify the main situations of SARS-CoV-2 transmission in the workplace, and hence for risk assessment and prevention programs.
In 2022–23, the human monkeypox virus (MPXV) caused a global outbreak in several non-endemic countries. Here, we evaluated the diagnostic performance of four real-time qualitative PCR assays for the laboratory diagnosis of mpox (monkeypox) monkeypox disease. From July to August 2022, 27 positive and 10 negative specimens (lesion, crust and exudate swabs) were tested in the laboratory of the Hygiene Unit of the San Martino Hospital (Genoa, Italy) by using home-made real-time PCR to detect MPXV generic G2R_G DNA. According to the manufacturer’s instructions, we also retrospectively analyzed these specimens using RealCycler MONK-UX/-GX (Progenie Molecular), STANDARD M10 MPX/OPX (SD Biosensor), Novaplex MPXV (Seegene Inc.) and RealStar Orthopoxvirus PCR Kit 1.0 (Altona Diagnostics) assays, recognized as research-use-only tests. The diagnostic accuracy and sensitivity of these assays ranged from 97.3% (95% CI: 86.2–99.5%) to 100% (95% CI: 90.6–100%) and 96.3% (95% CI: 81.72–99.34%) to 100% (95% CI: 72.2–100%), respectively. The RealCycler MONK-UX and STANDARD M10 MPX/OPX did not detect one positive sample with a cycle threshold of 36. The overall specificity was 100% (95% CI: 72.2–100%), and Cohen’s Kappa values ranged from 1 (95% CI: 0.67–1) to 0.93 (95% CI: 0.61–1). As they are highly accurate, reliable and user-friendly, these tests should be recommended for the routine or rapid laboratory discrimination of mpox from other rash illnesses.